208 related articles for article (PubMed ID: 21651245)
1. Effects of Mobile-Phase Composition and Temperature on the Selectivity of Poly(N-isopropylacrylamide)-Bonded Silica Gel in Reversed-Phase Liquid Chromatography.
Go H; Sudo Y; Hosoya K; Ikegami T; Tanaka N
Anal Chem; 1998 Oct; 70(19):4086-93. PubMed ID: 21651245
[TBL] [Abstract][Full Text] [Related]
2. Temperature-Responsive Chromatography Using Poly(N-isopropylacrylamide)-Modified Silica.
Kanazawa H; Yamamoto K; Matsushima Y; Takai N; Kikuchi A; Sakurai Y; Okano T
Anal Chem; 1996 Jan; 68(1):100-5. PubMed ID: 21619225
[TBL] [Abstract][Full Text] [Related]
3. Combined effects of mobile phase composition and temperature on the retention of homologous and polar test compounds on polydentate C8 column.
Jandera P; Krupczyńska K; Vynuchalová K; Buszewski B
J Chromatogr A; 2010 Sep; 1217(39):6052-60. PubMed ID: 20728897
[TBL] [Abstract][Full Text] [Related]
4. Insights into the retention mechanism on an octadecylsiloxane-bonded silica stationary phase (HyPURITY C18) in reversed-phase liquid chromatography.
Poole CF; Kiridena W; DeKay C; Koziol WW; Rosencrans RD
J Chromatogr A; 2006 May; 1115(1-2):133-41. PubMed ID: 16564531
[TBL] [Abstract][Full Text] [Related]
5. Retention and selectivity effects caused by bonding of a polar urea-type ligand to silica: a study on mixed-mode retention mechanisms and the pivotal role of solute-silanol interactions in the hydrophilic interaction chromatography elution mode.
Bicker W; Wu J; Yeman H; Albert K; Lindner W
J Chromatogr A; 2011 Feb; 1218(7):882-95. PubMed ID: 21067765
[TBL] [Abstract][Full Text] [Related]
6. Secondary isotope effects in liquid chromatography behaviour of 2H and 3H labelled solutes and solvents.
Valleix A; Carrat S; Caussignac C; Léonce E; Tchapla A
J Chromatogr A; 2006 May; 1116(1-2):109-26. PubMed ID: 16631181
[TBL] [Abstract][Full Text] [Related]
7. Temperature-responsive liquid chromatography. 2. Effects of hydrophobic groups in N-isopropylacrylamide copolymer-modified silica.
Kanazawa H; Kashiwase Y; Yamamoto K; Matsushima Y; Kikuchi A; Sakurai Y; Okano T
Anal Chem; 1997 Mar; 69(5):823-30. PubMed ID: 9068270
[TBL] [Abstract][Full Text] [Related]
8. Selectivity of calixarene-bonded silica phases in HPLC: Description of special characteristics with a multiple term linear equation at different methanol concentrations.
Schneider C; Jira T
J Sep Sci; 2010 Oct; 33(19):2943-55. PubMed ID: 20812230
[TBL] [Abstract][Full Text] [Related]
9. Hydrophilic interaction chromatography in nonaqueous elution mode for separation of hydrophilic analytes on silica-based packings with noncharged polar bondings.
Bicker W; Wu J; Lämmerhofer M; Lindner W
J Sep Sci; 2008 Sep; 31(16-17):2971-87. PubMed ID: 18785146
[TBL] [Abstract][Full Text] [Related]
10. Stationary and mobile phases in hydrophilic interaction chromatography: a review.
Jandera P
Anal Chim Acta; 2011 Apr; 692(1-2):1-25. PubMed ID: 21501708
[TBL] [Abstract][Full Text] [Related]
11. Separation of peptides with an aqueous mobile phase by temperature-responsive chromatographic column.
Liu Z; Liang Y; Geng F; Ge C; Ullah K; Lv F; Dai R; Zhang Y; Deng Y
J Sep Sci; 2012 Aug; 35(16):2069-74. PubMed ID: 22753094
[TBL] [Abstract][Full Text] [Related]
12. Hydrosilated silica-based columns: the effects of mobile phase and temperature on dual hydrophilic-reversed-phase separation mechanism of phenolic acids.
Soukup J; Jandera P
J Chromatogr A; 2012 Mar; 1228():125-34. PubMed ID: 21782183
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of ternary mobile phases for reversed-phase liquid chromatography: effect of composition on retention mechanism.
Coym JW
J Chromatogr A; 2010 Sep; 1217(38):5957-64. PubMed ID: 20723902
[TBL] [Abstract][Full Text] [Related]
14. Characterization of calixarene-bonded stationary phases.
Schneider C; Menyes U; Jira T
J Sep Sci; 2010 Oct; 33(19):2930-42. PubMed ID: 20603840
[TBL] [Abstract][Full Text] [Related]
15. Effects of graft densities and chain lengths on separation of bioactive compounds by nanolayered thermoresponsive polymer brush surfaces.
Nagase K; Kobayashi J; Kikuchi A; Akiyama Y; Kanazawa H; Okano T
Langmuir; 2008 Jan; 24(2):511-7. PubMed ID: 18085801
[TBL] [Abstract][Full Text] [Related]
16. Comparison of nonaqueous hydrophilic interaction chromatography with aqueous normal-phase chromatography on hydrosilated silica-based stationary phases.
Soukup J; Jandera P
J Sep Sci; 2013 Sep; 36(17):2753-9. PubMed ID: 23801486
[TBL] [Abstract][Full Text] [Related]
17. Problems connected with HPLC separation of pilocarpine from its degradation products by means of silica gel and water-based mobile phase.
Vespalec R; Fiedorová M; Subert J
Pharmazie; 1988 Oct; 43(10):689-91. PubMed ID: 2850587
[TBL] [Abstract][Full Text] [Related]
18. Study of temperature-responsibility on the surfaces of a thermo-responsive polymer modified stationary phase.
Ayano E; Okada Y; Sakamoto C; Kanazawa H; Kikuchi A; Okano T
J Chromatogr A; 2006 Jun; 1119(1-2):51-7. PubMed ID: 16487534
[TBL] [Abstract][Full Text] [Related]
19. Retention behavior of phenols, anilines, and alkylbenzenes in liquid chromatographic separations using subcritical water as the mobile phase.
Yang Y; Jones AD; Eaton CD
Anal Chem; 1999 Sep; 71(17):3808-13. PubMed ID: 21662885
[TBL] [Abstract][Full Text] [Related]
20. Retention behaviour of imidazolium ionic liquid cations on 1.7 μm ethylene bridged hybrid silica column using acetonitrile-rich and water-rich mobile phases.
Orentienė A; Olšauskaitė V; Vičkačkaitė V; Padarauskas A
J Chromatogr A; 2011 Sep; 1218(39):6884-91. PubMed ID: 21871632
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]