BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 21657183)

  • 1. Invalid measurement of plasma albumin using bromcresol green methodology in penguins (Spheniscus species).
    Cray C; Wack A; Arheart KL
    J Avian Med Surg; 2011 Mar; 25(1):14-22. PubMed ID: 21657183
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Determination of plasma albumin concentration in healthy and diseased turtles: a comparison of protein electrophoresis and the bromcresol green dye-binding method.
    Müller K; Brunnberg L
    Vet Clin Pathol; 2010 Mar; 39(1):79-82. PubMed ID: 19702665
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Lithium heparinised blood-collection tubes give falsely low albumin results with an automated bromcresol green method in haemodialysis patients.
    Meng QH; Krahn J
    Clin Chem Lab Med; 2008; 46(3):396-400. PubMed ID: 18254716
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Capillary Zone Electrophoresis in Humboldt Penguins (
    Leineweber C; Lücht M; Gohl C; Steinmetz HW; Marschang RE
    J Avian Med Surg; 2024 Apr; 38(1):1-6. PubMed ID: 38686882
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Bromcresol green assay is nonspecific for rat plasma albumin.
    Barber BJ; Stanhope VL
    Am J Physiol; 1992 Jan; 262(1 Pt 2):H299-302. PubMed ID: 1733318
    [TBL] [Abstract][Full Text] [Related]  

  • 6. New automated dye-binding method for serum albumin determination with bromcresol purple.
    Pinnell AE; Northam BE
    Clin Chem; 1978 Jan; 24(1):80-6. PubMed ID: 618669
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Overestimation of canine albumin concentration with the bromcresol green method in heparinized plasma samples.
    Stokol T; Tarrant JM; Scarlett JM
    Vet Clin Pathol; 2001; 30(4):170-176. PubMed ID: 12024297
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Overestimation of Albumin Measured by Bromocresol Green vs Bromocresol Purple Method: Influence of Acute-Phase Globulins.
    Garcia Moreira V; Beridze Vaktangova N; Martinez Gago MD; Laborda Gonzalez B; Garcia Alonso S; Fernandez Rodriguez E
    Lab Med; 2018 Oct; 49(4):355-361. PubMed ID: 29790973
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Serum globulins contribute to the discrepancies observed between the bromocresol green and bromocresol purple assays of serum albumin concentration.
    Xu Y; Wang L; Wang J; Liang H; Jiang X
    Br J Biomed Sci; 2011; 68(3):120-5. PubMed ID: 21950203
    [TBL] [Abstract][Full Text] [Related]  

  • 10. APPLICATION OF 3-HYDROXYBUTYRATE MEASUREMENT AND PLASMA PROTEIN ELECTROPHORESIS IN THE DIAGNOSIS OF ASPERGILLOSIS IN AFRICAN PENGUINS ( SPHENISCUS DEMERSUS).
    Desoubeaux G; Rodriguez M; Bronson E; Sirpenski G; Cray C
    J Zoo Wildl Med; 2018 Sep; 49(3):696-703. PubMed ID: 30212328
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Problems associated with plasma albumin estimation in nephrotic syndrome using the bromocresol green method.
    Agbedana EO; Oshota JO; Taylor GO
    Afr J Med Med Sci; 1993 Sep; 22(3):45-8. PubMed ID: 7530900
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Albumin concentration determined by the modified bromocresol purple method is superior to that by the bromocresol green method for assessing nutritional status in malnourished patients with inflammation.
    Ueno T; Hirayama S; Ito M; Nishioka E; Fukushima Y; Satoh T; Idei M; Horiuchi Y; Shoji H; Ohmura H; Shimizu T; Miida T
    Ann Clin Biochem; 2013 Nov; 50(Pt 6):576-84. PubMed ID: 23897106
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of the clinical applicability of bromcresol purple method for measuring serum albumin.
    Zeng FY; Zhang YM; Yang Y; Wang Q
    Di Yi Jun Yi Da Xue Xue Bao; 2003 Apr; 23(4):369-71. PubMed ID: 12697479
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A study of the interaction between bromocresol green dye and bovine, ovine and equine serum globulins.
    Keay G; Doxey DL
    Vet Res Commun; 1984 Feb; 8(1):25-32. PubMed ID: 6202048
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Controversies in the determination of serum albumin concentration in chronic liver diseases].
    Uchida Y; Okuzumi Y; Fujishiro M; Kawamura K; Shibasaki M; Shimetani N; Suzuki K
    Rinsho Byori; 2006 Oct; 54(10):1008-12. PubMed ID: 17133989
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of bromcresol green and agarose protein electrophoresis for quantitation of serum albumin in multiple myeloma.
    Snozek CL; Saenger AK; Greipp PR; Bryant SC; Kyle RA; Rajkumar SV; Katzmann JA
    Clin Chem; 2007 Jun; 53(6):1099-103. PubMed ID: 17463172
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Bias between two methods of albumin measurement in the white rhinoceros, Ceratotherium simum.
    Hooijberg EH; Cray C; Miller M; Buss P; Steenkamp G; Goddard A
    Vet Clin Pathol; 2020 Mar; 49(1):91-94. PubMed ID: 31925822
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Plasma protein electrophoresis as a prognostic indicator in Aspergillus species-infected Gentoo penguins (Pygoscelis papua papua).
    Naylor AD; Girling SJ; Brown D; Crompton CG; Pizzi R
    Vet Clin Pathol; 2017 Dec; 46(4):605-614. PubMed ID: 28692132
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The bromocresol green assay, but not the modified bromocresol purple assay, overestimates the serum albumin concentration in nephrotic syndrome through reaction with α2-macroglobulin.
    Ueno T; Hirayama S; Sugihara M; Miida T
    Ann Clin Biochem; 2016 Jan; 53(Pt 1):97-105. PubMed ID: 25673775
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The impact of the assay for measuring albumin on corrected ('adjusted') calcium concentrations.
    Labriola L; Wallemacq P; Gulbis B; Jadoul M
    Nephrol Dial Transplant; 2009 Jun; 24(6):1834-8. PubMed ID: 19182240
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.