312 related articles for article (PubMed ID: 21671952)
1. Percutaneous lead and system extraction in patients with cardiac resynchronization therapy (CRT) devices and coronary sinus leads.
Williams SE; Arujuna A; Whitaker J; Shetty AK; Bostock J; Patel N; Mobb M; Cooklin M; Gill J; Blauth C; Bucknall C; Hamid S; Rinaldi CA
Pacing Clin Electrophysiol; 2011 Oct; 34(10):1209-16. PubMed ID: 21671952
[TBL] [Abstract][Full Text] [Related]
2. Percutaneous extraction of leads from coronary sinus vein and branch by modified techniques.
Chu XM; Li XB; Zhang P; Wang L; Li D; Li B; An Y; Leng M; Duan JB; Guo JH
Chin Med J (Engl); 2012 Oct; 125(20):3707-11. PubMed ID: 23075729
[TBL] [Abstract][Full Text] [Related]
3. Trends, indications and outcomes of cardiac implantable device system extraction: a single UK centre experience over the last decade.
Arujuna A; Williams S; Whittaker J; Shetty A; Roy D; Bostock J; Kirubakaran S; O'Neill M; Gill J; Cooklin M; Patel N; Blauth C; Bucknall C; Hamid S; Rinaldi CA
Int J Clin Pract; 2012 Feb; 66(2):218-25. PubMed ID: 22257047
[TBL] [Abstract][Full Text] [Related]
4. Implications and outcome of permanent coronary sinus lead extraction and reimplantation.
Burke MC; Morton J; Lin AC; Tierney S; Desai A; Hong T; Kim S; Salem Y; Alberts M; Knight BP
J Cardiovasc Electrophysiol; 2005 Aug; 16(8):830-7. PubMed ID: 16101623
[TBL] [Abstract][Full Text] [Related]
5. Application of intravascular dissection devices for closed chest coronary sinus lead extraction: an interdisciplinary approach.
Lisy M; Kornberger A; Schmid E; Kalender G; Stock UA; Doernberger V; Steger V
Ann Thorac Surg; 2013 Apr; 95(4):1360-5. PubMed ID: 23453746
[TBL] [Abstract][Full Text] [Related]
6. Extraction of chronic pacemaker and defibrillator leads from the coronary sinus: laser infrequently used but required.
Hamid S; Arujuna A; Khan S; Ladwiniec A; McPhail M; Bostock J; Mobb M; Patel N; Bucknall C; Rinaldi CA
Europace; 2009 Feb; 11(2):213-5. PubMed ID: 19168497
[TBL] [Abstract][Full Text] [Related]
7. Cardiac resynchronization therapy after coronary sinus lead extraction: feasibility and mid-term outcome of transvenous reimplantation in a tertiary referral centre.
Zucchelli G; Bongiorni MG; Di Cori A; Soldati E; Solarino G; Fabiani I; Segreti L; De Lucia R; Viani S; Coluccia G; Paperini L
Europace; 2012 Apr; 14(4):515-21. PubMed ID: 22037541
[TBL] [Abstract][Full Text] [Related]
8. Multicenter experience with transvenous lead extraction of active fixation coronary sinus leads.
Maytin M; Carrillo RG; Baltodano P; Schaerf RH; Bongiorni MG; Di Cori A; Curnis A; Cooper JM; Kennergren C; Epstein LM
Pacing Clin Electrophysiol; 2012 Jun; 35(6):641-7. PubMed ID: 22432739
[TBL] [Abstract][Full Text] [Related]
9. Coronary sinus lead extraction in the era of cardiac resynchronization therapy: single center experience.
Kasravi B; Tobias S; Barnes MJ; Messenger JC
Pacing Clin Electrophysiol; 2005 Jan; 28(1):51-3. PubMed ID: 15660803
[TBL] [Abstract][Full Text] [Related]
10. Coronary sinus side branches for cardiac resynchronization therapy: prospective evaluation of availability, implant success, and procedural determinants.
Duray GZ; Hohnloser SH; Israel CW
J Cardiovasc Electrophysiol; 2008 May; 19(5):489-94. PubMed ID: 18298511
[TBL] [Abstract][Full Text] [Related]
11. A modified transvenous single mechanical dilatation technique to remove a chronically implanted active-fixation coronary sinus pacing lead.
Bongiorni MG; Di Cori A; Zucchelli G; Segreti L; De Lucia R; Paperini L; Soldati E
Pacing Clin Electrophysiol; 2011 Jul; 34(7):e66-9. PubMed ID: 20487357
[TBL] [Abstract][Full Text] [Related]
12. Coronary sinus lead extraction in CRT patients with CIED-related infection: risks, implications and outcomes.
Lisy M; Schmid E; Kalender G; Stock UA; Doernberger V; Khalil M; Kornberger A
Minerva Cardioangiol; 2015 Apr; 63(2):91-8. PubMed ID: 24941962
[TBL] [Abstract][Full Text] [Related]
13. Laser lead extraction: predictors of success and complications.
Roux JF; Pagé P; Dubuc M; Thibault B; Guerra PG; Macle L; Roy D; Talajic M; Khairy P
Pacing Clin Electrophysiol; 2007 Feb; 30(2):214-20. PubMed ID: 17338718
[TBL] [Abstract][Full Text] [Related]
14. Percutaneous coronary sinus interventions to facilitate implantation of left ventricular lead: a case series and review of literature.
Oto A; Aytemir K; Okutucu S; Canpolat U; Sahiner L; Ozkutlu H
J Card Fail; 2012 Apr; 18(4):321-9. PubMed ID: 22464774
[TBL] [Abstract][Full Text] [Related]
15. Cardiac venous left ventricular lead removal and reimplantation following device infection: a large single-center experience.
Rickard J; Tarakji K; Cronin E; Brunner MP; Jackson G; Baranowski B; Borek PP; Martin DO; Wazni O; Wilkoff BL
J Cardiovasc Electrophysiol; 2012 Nov; 23(11):1213-6. PubMed ID: 22862738
[TBL] [Abstract][Full Text] [Related]
16. Lead implant duration does not always predict ease of extraction: extraction sheath may be required at < 1 year.
Maytin M; Epstein LM; John RM
Pacing Clin Electrophysiol; 2011 Dec; 34(12):1615-20. PubMed ID: 22017453
[TBL] [Abstract][Full Text] [Related]
17. Coronary Sinus Lead Extraction.
Cronin EM; Wilkoff BL
Card Electrophysiol Clin; 2015 Dec; 7(4):661-71. PubMed ID: 26596810
[TBL] [Abstract][Full Text] [Related]
18. Active fixation mechanism complicates coronary sinus lead extraction and limits subsequent reimplantation targets.
Cronin EM; Ingelmo CP; Rickard J; Wazni OM; Martin DO; Wilkoff BL; Baranowski B
J Interv Card Electrophysiol; 2013 Jan; 36(1):81-6; discussion 86. PubMed ID: 22869386
[TBL] [Abstract][Full Text] [Related]
19. Long-term stability of endocardial left ventricular pacing leads placed via the coronary sinus.
Lin G; Anavekar NS; Webster TL; Rea RF; Hayes DL; Brady PA
Pacing Clin Electrophysiol; 2009 Sep; 32(9):1117-22. PubMed ID: 19719486
[TBL] [Abstract][Full Text] [Related]
20. Coronary Sinus Lead Extraction.
Cronin EM; Wilkoff BL
Heart Fail Clin; 2017 Jan; 13(1):105-115. PubMed ID: 27886917
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]