These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

276 related articles for article (PubMed ID: 21673383)

  • 1. Error in dynamic spring constant calibration of atomic force microscope probes due to nonuniform cantilevers.
    Frentrup H; Allen MS
    Nanotechnology; 2011 Jul; 22(29):295703. PubMed ID: 21673383
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantitative comparison of two independent lateral force calibration techniques for the atomic force microscope.
    Barkley SS; Deng Z; Gates RS; Reitsma MG; Cannara RJ
    Rev Sci Instrum; 2012 Feb; 83(2):023707. PubMed ID: 22380099
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accuracy of the spring constant of atomic force microscopy cantilevers by finite element method.
    Chen BY; Yeh MK; Tai NH
    Anal Chem; 2007 Feb; 79(4):1333-8. PubMed ID: 17297931
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accurate measurement of Atomic Force Microscope cantilever deflection excluding tip-surface contact with application to force calibration.
    Slattery AD; Blanch AJ; Quinton JS; Gibson CT
    Ultramicroscopy; 2013 Aug; 131():46-55. PubMed ID: 23685172
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Calibration of the spring constant of cantilevers of arbitrary shape using the phase signal in an atomic force microscope.
    Rawlings C; Durkan C
    Nanotechnology; 2012 Dec; 23(48):485708. PubMed ID: 23137943
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Calibration of higher eigenmode spring constants of atomic force microscope cantilevers.
    Lozano JR; Kiracofe D; Melcher J; Garcia R; Raman A
    Nanotechnology; 2010 Nov; 21(46):465502. PubMed ID: 20972309
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Precise atomic force microscope cantilever spring constant calibration using a reference cantilever array.
    Gates RS; Reitsma MG
    Rev Sci Instrum; 2007 Aug; 78(8):086101. PubMed ID: 17764361
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accurate flexural spring constant calibration of colloid probe cantilevers using scanning laser Doppler vibrometry.
    Gates RS; Osborn WA; Shaw GA
    Nanotechnology; 2015 Jun; 26(23):235704. PubMed ID: 25990652
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Atomic force microscope cantilever calibration using a focused ion beam.
    Slattery AD; Quinton JS; Gibson CT
    Nanotechnology; 2012 Jul; 23(28):285704. PubMed ID: 22728463
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Atomic force microscope cantilever spring constant evaluation for higher mode oscillations: a kinetostatic method.
    Tseytlin YM
    Rev Sci Instrum; 2008 Feb; 79(2 Pt 1):025102. PubMed ID: 18315324
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of cantilever geometry on the optical lever sensitivities and thermal noise method of the atomic force microscope.
    Sader JE; Lu J; Mulvaney P
    Rev Sci Instrum; 2014 Nov; 85(11):113702. PubMed ID: 25430115
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Accurate and precise calibration of AFM cantilever spring constants using laser Doppler vibrometry.
    Gates RS; Pratt JR
    Nanotechnology; 2012 Sep; 23(37):375702. PubMed ID: 22922668
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Study of thermal and acoustic noise interferences in low stiffness atomic force microscope cantilevers and characterization of their dynamic properties.
    Boudaoud M; Haddab Y; Le Gorrec Y; Lutz P
    Rev Sci Instrum; 2012 Jan; 83(1):013704. PubMed ID: 22299959
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cantilever spring constant calibration using laser Doppler vibrometry.
    Ohler B
    Rev Sci Instrum; 2007 Jun; 78(6):063701. PubMed ID: 17614610
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Nondestructive and noncontact method for determining the spring constant of rectangular cantilevers.
    Golovko DS; Haschke T; Wiechert W; Bonaccurso E
    Rev Sci Instrum; 2007 Apr; 78(4):043705. PubMed ID: 17477668
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Spring constant calibration of atomic force microscopy cantilevers with a piezosensor transfer standard.
    Langlois ED; Shaw GA; Kramar JA; Pratt JR; Hurley DC
    Rev Sci Instrum; 2007 Sep; 78(9):093705. PubMed ID: 17902953
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Influence of Poisson's ratio variation on lateral spring constant of atomic force microscopy cantilevers.
    Yeh MK; Tai NH; Chen BY
    Ultramicroscopy; 2008 Sep; 108(10):1025-9. PubMed ID: 18547729
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Calibration of atomic force microscope cantilevers using standard and inverted static methods assisted by FIB-milled spatial markers.
    Slattery AD; Blanch AJ; Quinton JS; Gibson CT
    Nanotechnology; 2013 Jan; 24(1):015710. PubMed ID: 23220746
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of anisotropic material property on the spring constant and the resonant frequency of atomic force microscope cantilever.
    Yeh MK; Tai NH; Chen BY
    Rev Sci Instrum; 2009 Apr; 80(4):043705. PubMed ID: 19405664
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Interlaboratory round robin on cantilever calibration for AFM force spectroscopy.
    te Riet J; Katan AJ; Rankl C; Stahl SW; van Buul AM; Phang IY; Gomez-Casado A; Schön P; Gerritsen JW; Cambi A; Rowan AE; Vancso GJ; Jonkheijm P; Huskens J; Oosterkamp TH; Gaub H; Hinterdorfer P; Figdor CG; Speller S
    Ultramicroscopy; 2011 Dec; 111(12):1659-69. PubMed ID: 22094372
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.