These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Endoscopic removal of malfunctioning biliary self-expandable metallic stents. Familiari P; Bulajic M; Mutignani M; Lee LS; Spera G; Spada C; Tringali A; Costamagna G Gastrointest Endosc; 2005 Dec; 62(6):903-10. PubMed ID: 16301035 [TBL] [Abstract][Full Text] [Related]
3. Difficult removal of fully covered self expandable metal stents (SEMS) for benign biliary strictures: the "SEMS in SEMS" technique. Tringali A; Blero D; Boškoski I; Familiari P; Perri V; Devière J; Costamagna G Dig Liver Dis; 2014 Jun; 46(6):568-71. PubMed ID: 24661988 [TBL] [Abstract][Full Text] [Related]
4. Endoscopic trimming of metallic stents with the use of argon plasma. Christiaens P; Decock S; Buchel O; Bulté K; Moons V; D'Haens G; Van Olmen G Gastrointest Endosc; 2008 Feb; 67(2):369-71. PubMed ID: 18226706 [TBL] [Abstract][Full Text] [Related]
5. Predictive factors for the failure of endoscopic stent-in-stent self-expandable metallic stent placement to treat malignant hilar biliary obstruction. Sugimoto M; Takagi T; Suzuki R; Konno N; Asama H; Watanabe K; Nakamura J; Kikuchi H; Waragai Y; Takasumi M; Sato Y; Hikichi T; Ohira H World J Gastroenterol; 2017 Sep; 23(34):6273-6280. PubMed ID: 28974893 [TBL] [Abstract][Full Text] [Related]
6. Covered vs. uncovered self-expandable metal stents for malignant distal biliary strictures: a systematic review and meta-analysis. Tringali A; Hassan C; Rota M; Rossi M; Mutignani M; Aabakken L Endoscopy; 2018 Jun; 50(6):631-641. PubMed ID: 29342491 [TBL] [Abstract][Full Text] [Related]
7. Clinical efficacy of anti-migration features in fully covered metallic stents for anastomotic biliary strictures after liver transplantation: comparison of conventional and anti-migration stents. Bordaçahar B; Perdigao F; Leblanc S; Barret M; Duchmann JC; Guillaumot MA; Chaussade S; Scatton O; Prat F Gastrointest Endosc; 2018 Oct; 88(4):655-664. PubMed ID: 30003877 [TBL] [Abstract][Full Text] [Related]
9. A multicenter analysis of safety and outcome of removal of a fully covered self-expandable metal stent during ERCP. Kasher JA; Corasanti JG; Tarnasky PR; McHenry L; Fogel E; Cunningham J Gastrointest Endosc; 2011 Jun; 73(6):1292-7. PubMed ID: 21470603 [TBL] [Abstract][Full Text] [Related]
10. Efficacy of a modified short fully covered self-expandable metal stent for perihilar benign biliary strictures. Lee TH; Moon JH; Lee YN; Jo SJ; Park JK; Yang JK; Cha SW; Cho YD; Park SH J Gastroenterol Hepatol; 2021 Apr; 36(4):1057-1063. PubMed ID: 32926577 [TBL] [Abstract][Full Text] [Related]
11. Endoscopic removal of biliary uncovered self-expandable metal stents in one patient placed 15 years ago. Yu T; Zhang L; Hou S J Hepatobiliary Pancreat Sci; 2022 Apr; 29(4):e25-e27. PubMed ID: 34657395 [TBL] [Abstract][Full Text] [Related]
12. Endoscopic removal of a spontaneously fractured biliary uncovered self-expandable metal stent. Kawakubo K; Isayama H; Tsujino T; Nakai Y; Sasahira N; Kogure H; Hamada T; Nagano R; Miyabayashi K; Yamamoto K; Mohri D; Sasaki T; Ito Y; Yamamoto N; Hirano K; Tada M; Koike K Dig Endosc; 2012 May; 24(3):182-4. PubMed ID: 22507093 [TBL] [Abstract][Full Text] [Related]
13. Fully covered self-expandable metal stents to dilate persistent pancreatic strictures in chronic pancreatitis: long-term follow-up from a prospective study. Tringali A; Vadalà di Prampero SF; Landi R; Bove V; Familiari P; Hamanaka J; Attili F; Costamagna G Gastrointest Endosc; 2018 Dec; 88(6):939-946. PubMed ID: 30142349 [TBL] [Abstract][Full Text] [Related]
14. Temporary placement of covered self-expandable metallic stents in the management of benign biliary strictures. Yasuda I; Mukai T; Doi S; Tomita E; Moriwaki H Dig Endosc; 2012 May; 24 Suppl 1():28-33. PubMed ID: 22533748 [TBL] [Abstract][Full Text] [Related]
15. Trimming a metallic biliary stent using an argon plasma coagulator. Rerknimitr R; Naprasert P; Kongkam P; Kullavanijaya P Cardiovasc Intervent Radiol; 2007; 30(3):534-6. PubMed ID: 16933157 [TBL] [Abstract][Full Text] [Related]
16. Endoscopic biliary stent insertion through specialized duodenal stent for combined malignant biliary and duodenal obstruction facilitated by stent or PTBD guidance. Lee JJ; Hyun JJ; Choe JW; Lee DW; Kim SY; Jung SW; Jung YK; Koo JS; Yim HJ; Lee SW Scand J Gastroenterol; 2017 Nov; 52(11):1258-1262. PubMed ID: 28685637 [TBL] [Abstract][Full Text] [Related]
17. Combined endoscopic stent-in-stent placement for malignant biliary and duodenal obstruction by using a new duodenal metal stent (with videos). Moon JH; Choi HJ; Ko BM; Koo HC; Hong SJ; Cheon YK; Cho YD; Lee MS; Shim CS Gastrointest Endosc; 2009 Oct; 70(4):772-7. PubMed ID: 19595319 [TBL] [Abstract][Full Text] [Related]
18. Endoscopic removal of biliary self-expandable metallic stents: a prospective study. Shin HP; Kim MH; Jung SW; Kim JC; Choi EK; Han J; Lee SS; Seo DW; Lee SK Endoscopy; 2006 Dec; 38(12):1250-5. PubMed ID: 17163328 [TBL] [Abstract][Full Text] [Related]
19. No benefit of endoscopic sphincterotomy before biliary placement of self-expandable metal stents for unresectable pancreatic cancer. Hayashi T; Kawakami H; Osanai M; Ishiwatari H; Naruse H; Hisai H; Yanagawa N; Kaneto H; Koizumi K; Sakurai T; Sonoda T Clin Gastroenterol Hepatol; 2015 Jun; 13(6):1151-8.e2. PubMed ID: 25632802 [TBL] [Abstract][Full Text] [Related]
20. Covered self-expandable metal stents with an anti-migration system improve patency duration without increased complications compared with uncovered stents for distal biliary obstruction caused by pancreatic carcinoma: a randomized multicenter trial. Kitano M; Yamashita Y; Tanaka K; Konishi H; Yazumi S; Nakai Y; Nishiyama O; Uehara H; Mitoro A; Sanuki T; Takaoka M; Koshitani T; Arisaka Y; Shiba M; Hoki N; Sato H; Sasaki Y; Sato M; Hasegawa K; Kawabata H; Okabe Y; Mukai H Am J Gastroenterol; 2013 Nov; 108(11):1713-22. PubMed ID: 24042190 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]