687 related articles for article (PubMed ID: 21681898)
1. Comparison of closure strategies after balloon aortic valvuloplasty: suture mediated versus collagen based versus manual.
Ben-Dor I; Looser P; Bernardo N; Maluenda G; Torguson R; Xue Z; Lindsay J; Pichard AD; Satler LF; Waksman R
Catheter Cardiovasc Interv; 2011 Jul; 78(1):119-24. PubMed ID: 21681898
[TBL] [Abstract][Full Text] [Related]
2. "Double wire" angio-seal closure technique after balloon aortic valvuloplasty.
Bui QT; Kolansky DM; Bannan A; Herrmann HC
Catheter Cardiovasc Interv; 2010 Mar; 75(4):488-92. PubMed ID: 19937771
[TBL] [Abstract][Full Text] [Related]
3. Large calibre arterial access device closure for percutaneous aortic valve interventions: use of the Prostar system in 118 cases.
Cockburn J; de Belder A; Brooks M; Hutchinson N; Hill A; Trivedi U; Hildick-Smith D
Catheter Cardiovasc Interv; 2012 Jan; 79(1):143-9. PubMed ID: 21538787
[TBL] [Abstract][Full Text] [Related]
4. Vascular complications after balloon aortic valvuloplasty in recent years: Incidence and comparison of two hemostatic devices.
Dall'Ara G; Santarelli A; Marzocchi A; Bacchi Reggiani ML; Sabattini MR; Moretti C; Marrozzini C; Taglieri N; Baldazzi F; Franco N; Ortolani P; Chiarabelli M; Rodinò G; Piovaccari G; Rapezzi C; Saia F
Catheter Cardiovasc Interv; 2018 May; 91(6):E49-E55. PubMed ID: 28980387
[TBL] [Abstract][Full Text] [Related]
5. Safety and effectiveness of a novel vascular closure device: a prospective study of the ExoSeal compared to the Angio-Seal and ProGlide.
Kara K; Mahabadi AA; Rothe H; Müller P; Krüger J; Neubauer H; Klein-Wiele O; Mügge A; Kahlert P; Erbel R
J Endovasc Ther; 2014 Dec; 21(6):822-8. PubMed ID: 25453885
[TBL] [Abstract][Full Text] [Related]
6. Femoral access-related complications during percutaneous transcatheter aortic valve implantation comparing single versus double Prostar XL device closure.
Saleh N; De Palma R; Settergren M; Rück A
Catheter Cardiovasc Interv; 2015 Dec; 86(7):1255-61. PubMed ID: 26332528
[TBL] [Abstract][Full Text] [Related]
7. A randomized trial comparing compression, Perclose Proglide and Angio-Seal VIP for arterial closure following percutaneous coronary intervention: the CAP trial.
Martin JL; Pratsos A; Magargee E; Mayhew K; Pensyl C; Nunn M; Day F; Shapiro T
Catheter Cardiovasc Interv; 2008 Jan; 71(1):1-5. PubMed ID: 18098171
[TBL] [Abstract][Full Text] [Related]
8. Collagen plug-based vascular closure devices do not decrease vascular and bleeding complications occurring after balloon aortic valvuloplasty.
Leclercq F; Delseny D; Gervasoni R; Lattuca B; Roubille F; Cayla G; Macia JC
Arch Cardiovasc Dis; 2015 Apr; 108(4):250-7. PubMed ID: 25754907
[TBL] [Abstract][Full Text] [Related]
9. A randomised controlled trial comparing the routine use of an Angio-Seal STS device strategy with conventional femoral haemostasis methods in a district general hospital.
Behan MW; Large JK; Patel NR; Lloyd GW; Sulke AN
Int J Clin Pract; 2007 Mar; 61(3):367-72. PubMed ID: 17313602
[TBL] [Abstract][Full Text] [Related]
10. Efficacy and safety of antegrade common femoral artery access closure using the Angio-Seal device: experience with 1889 interventions for critical limb ischemia in diabetic patients.
Lupattelli T; Tannouri F; Garaci FG; Papa G; Pangos M; Somalvico F; Caravaggi C; Faglia E
J Endovasc Ther; 2010 Jun; 17(3):366-75. PubMed ID: 20557177
[TBL] [Abstract][Full Text] [Related]
11. Percutaneous suture closure for management of large French size arterial puncture in aortic valvuloplasty.
Solomon LW; Fusman B; Jolly N; Kim A; Feldman T
J Invasive Cardiol; 2001 Aug; 13(8):592-6. PubMed ID: 11481509
[TBL] [Abstract][Full Text] [Related]
12. Femoral arterial puncture management after percutaneous coronary procedures: a comparison of clinical outcomes and patient satisfaction between manual compression and two different vascular closure devices.
Duffin DC; Muhlestein JB; Allisson SB; Horne BD; Fowles RE; Sorensen SG; Revenaugh JR; Bair TL; Lappe DL
J Invasive Cardiol; 2001 May; 13(5):354-62. PubMed ID: 11385148
[TBL] [Abstract][Full Text] [Related]
13. The management of peripheral vascular complications associated with the use of percutaneous suture-mediated closure devices.
Sprouse LR; Botta DM; Hamilton IN
J Vasc Surg; 2001 Apr; 33(4):688-93. PubMed ID: 11296318
[TBL] [Abstract][Full Text] [Related]
14. The efficacy and safety of closure of brachial access using the AngioSeal closure device: experience with 161 interventions in diabetic patients with critical limb ischemia.
Lupattelli T; Clerissi J; Clerici G; Minnella DP; Casini A; Losa S; Faglia E
J Vasc Surg; 2008 Apr; 47(4):782-8. PubMed ID: 18295438
[TBL] [Abstract][Full Text] [Related]
15. Comparison of suture-based vascular closure devices in transfemoral transcatheter aortic valve implantation.
Barbanti M; Capranzano P; Ohno Y; Gulino S; Sgroi C; Immè S; Tamburino C; Cannata S; Patanè M; Di Stefano D; Todaro D; Di Simone E; Deste W; Gargiulo G; Capodanno D; Grasso C; Tamburino C
EuroIntervention; 2015 Oct; 11(6):690-7. PubMed ID: 26499222
[TBL] [Abstract][Full Text] [Related]
16. Prospective nonrandomized trial of manual compression and Angio-Seal and Starclose arterial closure devices in common femoral punctures.
Ratnam LA; Raja J; Munneke GJ; Morgan RA; Belli AM
Cardiovasc Intervent Radiol; 2007; 30(2):182-8. PubMed ID: 17200896
[TBL] [Abstract][Full Text] [Related]
17. The use of percutaneous suture-mediated closure for the management of 14 French femoral venous access.
Mylonas I; Sakata Y; Salinger M; Sanborn TA; Feldman T
J Invasive Cardiol; 2006 Jul; 18(7):299-302. PubMed ID: 16816433
[TBL] [Abstract][Full Text] [Related]
18. Simple, effective and safe vascular access site closure with the double-ProGlide preclose technique in 162 patients receiving transfemoral transcatheter aortic valve implantation.
Griese DP; Reents W; Diegeler A; Kerber S; Babin-Ebell J
Catheter Cardiovasc Interv; 2013 Nov; 82(5):E734-41. PubMed ID: 23765732
[TBL] [Abstract][Full Text] [Related]
19. Comparative data of single versus double proglide vascular preclose technique after percutaneous transfemoral transcatheter aortic valve implantation from the optimized catheter valvular intervention (OCEAN-TAVI) japanese multicenter registry.
Kodama A; Yamamoto M; Shimura T; Kagase A; Koyama Y; Tada N; Takagi K; Araki M; Yamanaka F; Shirai S; Watanabe Y; Hayashida K
Catheter Cardiovasc Interv; 2017 Sep; 90(3):E55-E62. PubMed ID: 27785881
[TBL] [Abstract][Full Text] [Related]
20. Early ambulation after percutaneous femoral access with use of closure devices and hemostatic agents.
Engelbert TL; Scholten A; Thompson K; Spivack A; Kansal N
Ann Vasc Surg; 2010 May; 24(4):518-23. PubMed ID: 20451795
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]