These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

493 related articles for article (PubMed ID: 21689559)

  • 1. Fatigue testing of controlled memory wire nickel-titanium rotary instruments.
    Shen Y; Qian W; Abtin H; Gao Y; Haapasalo M
    J Endod; 2011 Jul; 37(7):997-1001. PubMed ID: 21689559
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of environment on fatigue failure of controlled memory wire nickel-titanium rotary instruments.
    Shen Y; Qian W; Abtin H; Gao Y; Haapasalo M
    J Endod; 2012 Mar; 38(3):376-80. PubMed ID: 22341078
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Metallurgical characterization of controlled memory wire nickel-titanium rotary instruments.
    Shen Y; Zhou HM; Zheng YF; Campbell L; Peng B; Haapasalo M
    J Endod; 2011 Nov; 37(11):1566-71. PubMed ID: 22000465
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cyclic fatigue testing and metallographic analysis of nickel-titanium rotary instruments.
    Pirani C; Cirulli PP; Chersoni S; Micele L; Ruggeri O; Prati C
    J Endod; 2011 Jul; 37(7):1013-6. PubMed ID: 21689562
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of fatigue on torsional failure of nickel-titanium controlled memory instruments.
    Campbell L; Shen Y; Zhou HM; Haapasalo M
    J Endod; 2014 Apr; 40(4):562-5. PubMed ID: 24666912
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Low-cycle fatigue of rotary NiTi endodontic instruments in hypochlorite solution.
    Cheung GS; Darvell BW
    Dent Mater; 2008 Jun; 24(6):753-9. PubMed ID: 17996288
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of the impact of raw materials on the fatigue and mechanical properties of ProFile Vortex rotary instruments.
    Gao Y; Gutmann JL; Wilkinson K; Maxwell R; Ammon D
    J Endod; 2012 Mar; 38(3):398-401. PubMed ID: 22341083
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of raw material and rotational speed on the cyclic fatigue of ProFile Vortex rotary instruments.
    Gao Y; Shotton V; Wilkinson K; Phillips G; Johnson WB
    J Endod; 2010 Jul; 36(7):1205-9. PubMed ID: 20630300
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Metallurgical characterization of M-Wire nickel-titanium shape memory alloy used for endodontic rotary instruments during low-cycle fatigue.
    Ye J; Gao Y
    J Endod; 2012 Jan; 38(1):105-7. PubMed ID: 22152631
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Does electropolishing improve the low-cycle fatigue behavior of a nickel-titanium rotary instrument in hypochlorite?
    Cheung GS; Shen Y; Darvell BW
    J Endod; 2007 Oct; 33(10):1217-21. PubMed ID: 17889693
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Correlation between experimental cyclic fatigue resistance and numerical stress analysis for nickel-titanium rotary files.
    Lee MH; Versluis A; Kim BM; Lee CJ; Hur B; Kim HC
    J Endod; 2011 Aug; 37(8):1152-7. PubMed ID: 21763912
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Deformation and fracture of Mtwo rotary nickel-titanium instruments after clinical use.
    Inan U; Gonulol N
    J Endod; 2009 Oct; 35(10):1396-9. PubMed ID: 19801238
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Impact of heat treatments on the fatigue resistance of different rotary nickel-titanium instruments.
    Braga LC; Faria Silva AC; Buono VT; de Azevedo Bahia MG
    J Endod; 2014 Sep; 40(9):1494-7. PubMed ID: 25146041
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of environment on low-cycle fatigue of a nickel-titanium instrument.
    Cheung GS; Shen Y; Darvell BW
    J Endod; 2007 Dec; 33(12):1433-7. PubMed ID: 18037053
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Cyclic fatigue analysis of a new generation of nickel titanium rotary instruments.
    Larsen CM; Watanabe I; Glickman GN; He J
    J Endod; 2009 Mar; 35(3):401-3. PubMed ID: 19249604
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Electropolishing enhances the resistance of nickel-titanium rotary files to corrosion-fatigue failure in hypochlorite.
    Praisarnti C; Chang JW; Cheung GS
    J Endod; 2010 Aug; 36(8):1354-7. PubMed ID: 20647095
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Torsion and bending properties of shape memory and superelastic nickel-titanium rotary instruments.
    Ninan E; Berzins DW
    J Endod; 2013 Jan; 39(1):101-4. PubMed ID: 23228266
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of cyclic fatigue resistance of three different rotary nickel-titanium instruments designed for retreatment.
    Inan U; Aydin C
    J Endod; 2012 Jan; 38(1):108-11. PubMed ID: 22152632
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Defects in nickel-titanium instruments after clinical use. Part 2: Fractographic analysis of fractured surface in a cohort study.
    Shen Y; Cheung GS; Peng B; Haapasalo M
    J Endod; 2009 Jan; 35(1):133-6. PubMed ID: 19084143
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A comparison of nickel-titanium rotary instruments manufactured using different methods and cross-sectional areas: ability to resist cyclic fatigue.
    Oh SR; Chang SW; Lee Y; Gu Y; Son WJ; Lee W; Baek SH; Bae KS; Choi GW; Lim SM; Kum KY
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2010 Apr; 109(4):622-8. PubMed ID: 20303058
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 25.