These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
254 related articles for article (PubMed ID: 21690275)
1. Improved plasma free metadrenaline analysis requires mixed mode cation exchange solid-phase extraction prior to liquid chromatography tandem mass spectrometry detection. Clarke MW; Cooke B; Hoad K; Glendenning P Ann Clin Biochem; 2011 Jul; 48(Pt 4):352-7. PubMed ID: 21690275 [TBL] [Abstract][Full Text] [Related]
2. Measurement of urinary metadrenaline and normetadrenaline by liquid chromatography tandem mass spectrometry for the diagnosis of phaeochromocytoma. Marrington R; Johnston J; Knowles S; Webster C Ann Clin Biochem; 2010 Sep; 47(Pt 5):467-75. PubMed ID: 20679366 [TBL] [Abstract][Full Text] [Related]
3. Quantitative measurement of plasma free metanephrines by ion-pairing solid phase extraction and liquid chromatography-tandem mass spectrometry with porous graphitic carbon column. He X; Gabler J; Yuan C; Wang S; Shi Y; Kozak M J Chromatogr B Analyt Technol Biomed Life Sci; 2011 Aug; 879(23):2355-9. PubMed ID: 21723209 [TBL] [Abstract][Full Text] [Related]
4. A simplified protein precipitation/mixed-mode cation-exchange solid-phase extraction, followed by high-speed liquid chromatography/mass spectrometry, for the determination of a basic drug in human plasma. Xue YJ; Akinsanya JB; Liu J; Unger SE Rapid Commun Mass Spectrom; 2006; 20(18):2660-8. PubMed ID: 16912986 [TBL] [Abstract][Full Text] [Related]
5. Urinary metanephrines by liquid chromatography tandem mass spectrometry: using multiple quantification methods to minimize interferences in a high throughput method. Clark ZD; Frank EL J Chromatogr B Analyt Technol Biomed Life Sci; 2011 Dec; 879(31):3673-80. PubMed ID: 22036658 [TBL] [Abstract][Full Text] [Related]
6. Performance of plasma free metanephrines measured by liquid chromatography-tandem mass spectrometry in the diagnosis of pheochromocytoma. Peaston RT; Graham KS; Chambers E; van der Molen JC; Ball S Clin Chim Acta; 2010 Apr; 411(7-8):546-52. PubMed ID: 20083099 [TBL] [Abstract][Full Text] [Related]
7. Plasma free metanephrine measurement using automated online solid-phase extraction HPLC tandem mass spectrometry. de Jong WH; Graham KS; van der Molen JC; Links TP; Morris MR; Ross HA; de Vries EG; Kema IP Clin Chem; 2007 Sep; 53(9):1684-93. PubMed ID: 17712005 [TBL] [Abstract][Full Text] [Related]
8. A simple and rapid analytical method based on solid-phase extraction and liquid chromatography-tandem mass spectrometry for the simultaneous determination of free catecholamines and metanephrines in urine and its application to routine clinical analysis. Woo HI; Yang JS; Oh HJ; Cho YY; Kim JH; Park HD; Lee SY Clin Biochem; 2016 May; 49(7-8):573-9. PubMed ID: 26779993 [TBL] [Abstract][Full Text] [Related]
9. Performance characteristics of an LC-MS/MS method for the determination of plasma metanephrines. Petteys BJ; Graham KS; Parnás ML; Holt C; Frank EL Clin Chim Acta; 2012 Oct; 413(19-20):1459-65. PubMed ID: 22687649 [TBL] [Abstract][Full Text] [Related]
10. Quantitation of Free Metanephrines in Plasma by Liquid Chromatography-Tandem Mass Spectrometry. Heideloff C; Payto D; Wang S Methods Mol Biol; 2016; 1378():139-47. PubMed ID: 26602126 [TBL] [Abstract][Full Text] [Related]
11. Measurement of plasma free metanephrine and normetanephrine by liquid chromatography-tandem mass spectrometry for diagnosis of pheochromocytoma. Lagerstedt SA; O'Kane DJ; Singh RJ Clin Chem; 2004 Mar; 50(3):603-11. PubMed ID: 14726465 [TBL] [Abstract][Full Text] [Related]
12. Multicenter study on the diagnostic value of a new RIA for the detection of free plasma metanephrines in the work-up for pheochromocytoma. Lenz T; Zorner J; Kirchmaier C; Pillitteri D; Badenhoop K; Bartel C; Geiger H; Hasselbacher K; Tuschy U; Westermann J; Salewski L Ann N Y Acad Sci; 2006 Aug; 1073():358-73. PubMed ID: 17102105 [TBL] [Abstract][Full Text] [Related]
13. Quantitative determination of corticosteroids in bovine milk using mixed-mode polymeric strong cation exchange solid-phase extraction and liquid chromatography-tandem mass spectrometry. Tölgyesi A; Tölgyesi L; Sharma VK; Sohn M; Fekete J J Pharm Biomed Anal; 2010 Dec; 53(4):919-28. PubMed ID: 20643526 [TBL] [Abstract][Full Text] [Related]
14. Comparison of molecularly imprinted, mixed-mode and hydrophilic balance sorbents performance in the solid-phase extraction of amphetamine drugs from wastewater samples for liquid chromatography-tandem mass spectrometry determination. González-Mariño I; Quintana JB; Rodríguez I; Rodil R; González-Peñas J; Cela R J Chromatogr A; 2009 Nov; 1216(48):8435-41. PubMed ID: 19846101 [TBL] [Abstract][Full Text] [Related]
15. Simple, rapid, and cost-effective microextraction by the packed sorbent method for quantifying of urinary free catecholamines and metanephrines using liquid chromatography-tandem mass spectrometry and its application in clinical analysis. Xiong X; Zhang Y Anal Bioanal Chem; 2020 May; 412(12):2763-2775. PubMed ID: 32130439 [TBL] [Abstract][Full Text] [Related]
16. Comparative study of an estradiol enzyme-linked immunosorbent assay kit, liquid chromatography-tandem mass spectrometry, and ultra performance liquid chromatography-quadrupole time of flight mass spectrometry for part-per-trillion analysis of estrogens in water samples. Farré M; Kuster M; Brix R; Rubio F; López de Alda MJ; Barceló D J Chromatogr A; 2007 Aug; 1160(1-2):166-75. PubMed ID: 17540393 [TBL] [Abstract][Full Text] [Related]
17. Determination of remifentanil in human plasma by liquid chromatography-tandem mass spectrometry utilizing micro extraction in packed syringe (MEPS) as sample preparation. Said R; Pohanka A; Andersson M; Beck O; Abdel-Rehim M J Chromatogr B Analyt Technol Biomed Life Sci; 2011 Apr; 879(11-12):815-8. PubMed ID: 21376673 [TBL] [Abstract][Full Text] [Related]
18. A novel method for the measurement of plasma metanephrines using online solid phase extraction-liquid chromatography tandem mass spectrometry. Adaway JE; Peitzsch M; Keevil BG Ann Clin Biochem; 2015 May; 52(Pt 3):361-9. PubMed ID: 25047871 [TBL] [Abstract][Full Text] [Related]
19. Measurement of plasma 5-hydroxyindole acetic acid by liquid chromatography tandem mass spectrometry--comparison with HPLC methodology. Miller AG; Brown H; Degg T; Allen K; Keevil BG J Chromatogr B Analyt Technol Biomed Life Sci; 2010 Mar; 878(7-8):695-9. PubMed ID: 20117968 [TBL] [Abstract][Full Text] [Related]
20. Development of a liquid chromatography-tandem mass spectrometry method for plasma-free metanephrines with ion-pairing turbulent flow online extraction. He X; Kozak M Anal Bioanal Chem; 2012 Mar; 402(9):3003-10. PubMed ID: 22349327 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]