These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

279 related articles for article (PubMed ID: 21691599)

  • 1. Effects of occlusal inclination and loading on mandibular bone remodeling: a finite element study.
    Rungsiyakull C; Rungsiyakull P; Li Q; Li W; Swain M
    Int J Oral Maxillofac Implants; 2011; 26(3):527-37. PubMed ID: 21691599
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Platform switching: biomechanical evaluation using three-dimensional finite element analysis.
    Tabata LF; Rocha EP; Barão VA; Assunção WG
    Int J Oral Maxillofac Implants; 2011; 26(3):482-91. PubMed ID: 21691594
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bone stress analysis of various angulations of mesiodistal implants with splinted crowns in the posterior mandible: a three-dimensional finite element study.
    Lan TH; Pan CY; Lee HE; Huang HL; Wang CH
    Int J Oral Maxillofac Implants; 2010; 25(4):763-70. PubMed ID: 20657872
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Finite element analysis of effect of prosthesis height, angle of force application, and implant offset on supporting bone.
    Sütpideler M; Eckert SE; Zobitz M; An KN
    Int J Oral Maxillofac Implants; 2004; 19(6):819-25. PubMed ID: 15623056
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Three-dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown.
    Sevimay M; Turhan F; Kiliçarslan MA; Eskitascioglu G
    J Prosthet Dent; 2005 Mar; 93(3):227-34. PubMed ID: 15775923
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The influence of occlusal loading location on stresses transferred to implant-supported prostheses and supporting bone: A three-dimensional finite element study.
    Eskitascioglu G; Usumez A; Sevimay M; Soykan E; Unsal E
    J Prosthet Dent; 2004 Feb; 91(2):144-50. PubMed ID: 14970760
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of prosthesis materials and prosthesis splinting on peri-implant bone stress around implants in poor-quality bone: a numeric analysis.
    Wang TM; Leu LJ; Wang J; Lin LD
    Int J Oral Maxillofac Implants; 2002; 17(2):231-7. PubMed ID: 11958406
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of diameter and length on stress distribution of the alveolar crest around immediate loading implants.
    Ding X; Liao SH; Zhu XH; Zhang XH; Zhang L
    Clin Implant Dent Relat Res; 2009 Dec; 11(4):279-87. PubMed ID: 18783411
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A finite element analysis of two different dental implants: stress distribution in the prosthesis, abutment, implant, and supporting bone.
    Quaresma SE; Cury PR; Sendyk WR; Sendyk C
    J Oral Implantol; 2008; 34(1):1-6. PubMed ID: 18390236
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Bone adaptation induced by non-passively fitting implant superstructures: a finite element analysis based on in vivo strain measurements.
    Winter W; Taylor TD; Karl M
    Int J Oral Maxillofac Implants; 2011; 26(6):1288-95. PubMed ID: 22167435
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Implant-bone interface stress distribution in immediately loaded implants of different diameters: a three-dimensional finite element analysis.
    Ding X; Zhu XH; Liao SH; Zhang XH; Chen H
    J Prosthodont; 2009 Jul; 18(5):393-402. PubMed ID: 19374710
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Treatment planning of implants when 3 mandibular posterior teeth are missing: a 3-dimensional finite element analysis.
    Chen XY; Zhang CY; Nie EM; Zhang MC
    Implant Dent; 2012 Aug; 21(4):340-3. PubMed ID: 22814561
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Influence of off-axis loading of an anterior maxillary implant: a 3-dimensional finite element analysis.
    Hsu ML; Chen FC; Kao HC; Cheng CK
    Int J Oral Maxillofac Implants; 2007; 22(2):301-9. PubMed ID: 17465356
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Loading of a single implant in simulated bone.
    Rungsiyakull P; Rungsiyakull C; Appleyard R; Li Q; Swain M; Klineberg I
    Int J Prosthodont; 2011; 24(2):140-3. PubMed ID: 21479281
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Three-dimensional finite-element analysis of functional stresses in different bone locations produced by implants placed in the maxillary posterior region of the sinus floor.
    Koca OL; Eskitascioglu G; Usumez A
    J Prosthet Dent; 2005 Jan; 93(1):38-44. PubMed ID: 15623996
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Stress and strain analysis of the bone-implant interface: a comparison of fiber-reinforced composite and titanium implants utilizing 3-dimensional finite element study.
    Shinya A; Ballo AM; Lassila LV; Shinya A; Närhi TO; Vallittu PK
    J Oral Implantol; 2011 Mar; 37 Spec No():133-40. PubMed ID: 20545537
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical interactions in tooth-implant-supported fixed partial dentures with variations in the number of splinted teeth and connector type: a finite element analysis.
    Lin CL; Wang JC; Chang WJ
    Clin Oral Implants Res; 2008 Jan; 19(1):107-17. PubMed ID: 17944965
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Three-dimensional finite element analysis of the effect of 1-piece superstructure on mandibular flexure.
    Naini RB; Nokar S
    Implant Dent; 2009 Oct; 18(5):428-37. PubMed ID: 22129961
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of splinted prosthesis supported a wide implant or two implants: a three-dimensional finite element analysis.
    Huang HL; Huang JS; Ko CC; Hsu JT; Chang CH; Chen MY
    Clin Oral Implants Res; 2005 Aug; 16(4):466-72. PubMed ID: 16117772
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Influence of bone and dental implant parameters on stress distribution in the mandible: a finite element study.
    Guan H; van Staden R; Loo YC; Johnson N; Ivanovski S; Meredith N
    Int J Oral Maxillofac Implants; 2009; 24(5):866-76. PubMed ID: 19865627
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.