100 related articles for article (PubMed ID: 21701031)
1. Assessment of MRI issues for a 3-T "immune" programmable CSF shunt valve.
Shellock FG; Bedwinek A; Oliver-Allen M; Wilson SF
AJR Am J Roentgenol; 2011 Jul; 197(1):202-7. PubMed ID: 21701031
[TBL] [Abstract][Full Text] [Related]
2. Magnetically programmable shunt valve: MRI at 3-Tesla.
Shellock FG; Wilson SF; Mauge CP
Magn Reson Imaging; 2007 Sep; 25(7):1116-21. PubMed ID: 17707175
[TBL] [Abstract][Full Text] [Related]
3. Assessment of MRI issues for the Argus II retinal prosthesis.
Weiland JD; Faraji B; Greenberg RJ; Humayun MS; Shellock FG
Magn Reson Imaging; 2012 Apr; 30(3):382-9. PubMed ID: 22260934
[TBL] [Abstract][Full Text] [Related]
4. Adjustable cerebrospinal fluid shunt valves in 3.0-Tesla MRI: a phantom study using explanted devices.
Akbar M; Aschoff A; Georgi JC; Nennig E; Heiland S; Abel R; Stippich C
Rofo; 2010 Jul; 182(7):594-602. PubMed ID: 20563954
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of MRI issues at 3-Tesla for a hospital identification (ID) wristband.
Oliver-Allen M; Valencerina S; Shellock FG
Magn Reson Imaging; 2012 Feb; 30(2):299-303. PubMed ID: 22055849
[TBL] [Abstract][Full Text] [Related]
6. Evaluation of MRI issues for an access port with a radiofrequency identification (RFID) tag.
Titterington B; Shellock FG
Magn Reson Imaging; 2013 Oct; 31(8):1439-44. PubMed ID: 23684963
[TBL] [Abstract][Full Text] [Related]
7. MRI safety of a programmable shunt assistant at 3 and 7 Tesla.
Mirzayan MJ; Klinge PM; Samii M; Goetz F; Krauss JK
Br J Neurosurg; 2012 Jun; 26(3):397-400. PubMed ID: 22348282
[TBL] [Abstract][Full Text] [Related]
8. Programmable CSF shunt valve: in vitro assessment of MR imaging safety at 3T.
Shellock FG; Habibi R; Knebel J
AJNR Am J Neuroradiol; 2006 Mar; 27(3):661-5. PubMed ID: 16552013
[TBL] [Abstract][Full Text] [Related]
9. Transcutaneous pressure-adjustable valves and magnetic resonance imaging: an ex vivo examination of the Codman-Medos programmable valve and the Sophy adjustable pressure valve.
Ortler M; Kostron H; Felber S
Neurosurgery; 1997 May; 40(5):1050-7; discussion 1057-8. PubMed ID: 9149264
[TBL] [Abstract][Full Text] [Related]
10. [Effect of magnetic fields from home-use magnetic induction therapy apparatuses on adjustable cerebrospinal fluid shunt valves].
Nakashima K; Oishi A; Itokawa H; Fujimoto M
No Shinkei Geka; 2010 Aug; 38(8):725-9. PubMed ID: 20697146
[TBL] [Abstract][Full Text] [Related]
11. Evaluation of MRI issues for a new neurological implant, the Sensor Reservoir.
Shellock FG; Knebel J; Prat AD
Magn Reson Imaging; 2013 Sep; 31(7):1245-50. PubMed ID: 23602731
[TBL] [Abstract][Full Text] [Related]
12. In vitro assessment of MRI issues at 3-Tesla for a breast tissue expander with a remote port.
Linnemeyer H; Shellock FG; Ahn CY
Magn Reson Imaging; 2014 Apr; 32(3):297-302. PubMed ID: 24418326
[TBL] [Abstract][Full Text] [Related]
13. Assessment of MRI issues for a new cerebral spinal fluid shunt, gravitational valve (GV).
Moghtader D; Crawack HJ; Miethke C; Dörlemann Z; Shellock FG
Magn Reson Imaging; 2017 Dec; 44():8-14. PubMed ID: 28735732
[TBL] [Abstract][Full Text] [Related]
14. [Magnetic resonance imaging of the brain in patients with cardiac pacemakers. Experimental and clinical investigations at 1.5 Tesla].
Schmiedel A; Hackenbroch M; Yang A; Nähle CP; Skowasch D; Meyer C; Schimpf R; Schild H; Sommer T
Rofo; 2005 May; 177(5):731-44. PubMed ID: 15871088
[TBL] [Abstract][Full Text] [Related]
15. Cervical external immobilization devices: evaluation of magnetic resonance imaging issues at 3.0 Tesla.
Diaz FL; Tweardy L; Shellock FG
Spine (Phila Pa 1976); 2010 Feb; 35(4):411-5. PubMed ID: 20110847
[TBL] [Abstract][Full Text] [Related]
16. Reliability of a new adjustable shunt device without the need for readjustment following 3-Tesla MRI.
Lüdemann W; Rosahl SK; Kaminsky J; Samii M
Childs Nerv Syst; 2005 Mar; 21(3):227-9. PubMed ID: 15657786
[TBL] [Abstract][Full Text] [Related]
17. Programmable Shunt Assistant tested in Cambridge shunt evaluation laboratory.
Czosnyka M; Czosnyka Z; Pickard JD
Acta Neurochir Suppl; 2012; 113():71-6. PubMed ID: 22116427
[TBL] [Abstract][Full Text] [Related]
18. Programmable shunts and headphones: Are they safe together?
Spader HS; Ratanaprasatporn L; Morrison JF; Grossberg JA; Cosgrove GR
J Neurosurg Pediatr; 2015 Oct; 16(4):402-5. PubMed ID: 26149436
[TBL] [Abstract][Full Text] [Related]
19. Effect of amusement park rides on programmable shunt valve settings.
Strahle J; Collins K; Stetler WR; Smith BW; Garton T; Garton C; Garton HJ; Maher CO
Pediatr Neurosurg; 2013; 49(1):21-3. PubMed ID: 24192584
[TBL] [Abstract][Full Text] [Related]
20. Thermal injuries associated with MRI.
Dempsey MF; Condon B
Clin Radiol; 2001 Jun; 56(6):457-65. PubMed ID: 11428795
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]