BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

100 related articles for article (PubMed ID: 21701031)

  • 1. Assessment of MRI issues for a 3-T "immune" programmable CSF shunt valve.
    Shellock FG; Bedwinek A; Oliver-Allen M; Wilson SF
    AJR Am J Roentgenol; 2011 Jul; 197(1):202-7. PubMed ID: 21701031
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Magnetically programmable shunt valve: MRI at 3-Tesla.
    Shellock FG; Wilson SF; Mauge CP
    Magn Reson Imaging; 2007 Sep; 25(7):1116-21. PubMed ID: 17707175
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Assessment of MRI issues for the Argus II retinal prosthesis.
    Weiland JD; Faraji B; Greenberg RJ; Humayun MS; Shellock FG
    Magn Reson Imaging; 2012 Apr; 30(3):382-9. PubMed ID: 22260934
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Adjustable cerebrospinal fluid shunt valves in 3.0-Tesla MRI: a phantom study using explanted devices.
    Akbar M; Aschoff A; Georgi JC; Nennig E; Heiland S; Abel R; Stippich C
    Rofo; 2010 Jul; 182(7):594-602. PubMed ID: 20563954
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of MRI issues at 3-Tesla for a hospital identification (ID) wristband.
    Oliver-Allen M; Valencerina S; Shellock FG
    Magn Reson Imaging; 2012 Feb; 30(2):299-303. PubMed ID: 22055849
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of MRI issues for an access port with a radiofrequency identification (RFID) tag.
    Titterington B; Shellock FG
    Magn Reson Imaging; 2013 Oct; 31(8):1439-44. PubMed ID: 23684963
    [TBL] [Abstract][Full Text] [Related]  

  • 7. MRI safety of a programmable shunt assistant at 3 and 7 Tesla.
    Mirzayan MJ; Klinge PM; Samii M; Goetz F; Krauss JK
    Br J Neurosurg; 2012 Jun; 26(3):397-400. PubMed ID: 22348282
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Programmable CSF shunt valve: in vitro assessment of MR imaging safety at 3T.
    Shellock FG; Habibi R; Knebel J
    AJNR Am J Neuroradiol; 2006 Mar; 27(3):661-5. PubMed ID: 16552013
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transcutaneous pressure-adjustable valves and magnetic resonance imaging: an ex vivo examination of the Codman-Medos programmable valve and the Sophy adjustable pressure valve.
    Ortler M; Kostron H; Felber S
    Neurosurgery; 1997 May; 40(5):1050-7; discussion 1057-8. PubMed ID: 9149264
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Effect of magnetic fields from home-use magnetic induction therapy apparatuses on adjustable cerebrospinal fluid shunt valves].
    Nakashima K; Oishi A; Itokawa H; Fujimoto M
    No Shinkei Geka; 2010 Aug; 38(8):725-9. PubMed ID: 20697146
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of MRI issues for a new neurological implant, the Sensor Reservoir.
    Shellock FG; Knebel J; Prat AD
    Magn Reson Imaging; 2013 Sep; 31(7):1245-50. PubMed ID: 23602731
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In vitro assessment of MRI issues at 3-Tesla for a breast tissue expander with a remote port.
    Linnemeyer H; Shellock FG; Ahn CY
    Magn Reson Imaging; 2014 Apr; 32(3):297-302. PubMed ID: 24418326
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Assessment of MRI issues for a new cerebral spinal fluid shunt, gravitational valve (GV).
    Moghtader D; Crawack HJ; Miethke C; Dörlemann Z; Shellock FG
    Magn Reson Imaging; 2017 Dec; 44():8-14. PubMed ID: 28735732
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Magnetic resonance imaging of the brain in patients with cardiac pacemakers. Experimental and clinical investigations at 1.5 Tesla].
    Schmiedel A; Hackenbroch M; Yang A; Nähle CP; Skowasch D; Meyer C; Schimpf R; Schild H; Sommer T
    Rofo; 2005 May; 177(5):731-44. PubMed ID: 15871088
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Cervical external immobilization devices: evaluation of magnetic resonance imaging issues at 3.0 Tesla.
    Diaz FL; Tweardy L; Shellock FG
    Spine (Phila Pa 1976); 2010 Feb; 35(4):411-5. PubMed ID: 20110847
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reliability of a new adjustable shunt device without the need for readjustment following 3-Tesla MRI.
    Lüdemann W; Rosahl SK; Kaminsky J; Samii M
    Childs Nerv Syst; 2005 Mar; 21(3):227-9. PubMed ID: 15657786
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Programmable Shunt Assistant tested in Cambridge shunt evaluation laboratory.
    Czosnyka M; Czosnyka Z; Pickard JD
    Acta Neurochir Suppl; 2012; 113():71-6. PubMed ID: 22116427
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Programmable shunts and headphones: Are they safe together?
    Spader HS; Ratanaprasatporn L; Morrison JF; Grossberg JA; Cosgrove GR
    J Neurosurg Pediatr; 2015 Oct; 16(4):402-5. PubMed ID: 26149436
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of amusement park rides on programmable shunt valve settings.
    Strahle J; Collins K; Stetler WR; Smith BW; Garton T; Garton C; Garton HJ; Maher CO
    Pediatr Neurosurg; 2013; 49(1):21-3. PubMed ID: 24192584
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Thermal injuries associated with MRI.
    Dempsey MF; Condon B
    Clin Radiol; 2001 Jun; 56(6):457-65. PubMed ID: 11428795
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.