These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
239 related articles for article (PubMed ID: 21720851)
1. A CCD-based fluorescence imaging system for real-time loop-mediated isothermal amplification-based rapid and sensitive detection of waterborne pathogens on microchips. Ahmad F; Seyrig G; Tourlousse DM; Stedtfeld RD; Tiedje JM; Hashsham SA Biomed Microdevices; 2011 Oct; 13(5):929-37. PubMed ID: 21720851 [TBL] [Abstract][Full Text] [Related]
2. A polymer microfluidic chip for quantitative detection of multiple water- and foodborne pathogens using real-time fluorogenic loop-mediated isothermal amplification. Tourlousse DM; Ahmad F; Stedtfeld RD; Seyrig G; Tiedje JM; Hashsham SA Biomed Microdevices; 2012 Aug; 14(4):769-78. PubMed ID: 22566273 [TBL] [Abstract][Full Text] [Related]
3. Most probable number - loop mediated isothermal amplification (MPN-LAMP) for quantifying waterborne pathogens in <25min. Ahmad F; Stedtfeld RD; Waseem H; Williams MR; Cupples AM; Tiedje JM; Hashsham SA J Microbiol Methods; 2017 Jan; 132():27-33. PubMed ID: 27856278 [TBL] [Abstract][Full Text] [Related]
4. An integrated microfluidic loop-mediated-isothermal-amplification system for rapid sample pre-treatment and detection of viruses. Wang CH; Lien KY; Wang TY; Chen TY; Lee GB Biosens Bioelectron; 2011 Jan; 26(5):2045-52. PubMed ID: 20869865 [TBL] [Abstract][Full Text] [Related]
5. Selection of fluorescent DNA dyes for real-time LAMP with portable and simple optics. Seyrig G; Stedtfeld RD; Tourlousse DM; Ahmad F; Towery K; Cupples AM; Tiedje JM; Hashsham SA J Microbiol Methods; 2015 Dec; 119():223-7. PubMed ID: 26554941 [TBL] [Abstract][Full Text] [Related]
6. Quantitative detection of Vibrio vulnificus in raw oysters by real-time loop-mediated isothermal amplification. Han F; Ge B Int J Food Microbiol; 2010 Aug; 142(1-2):60-6. PubMed ID: 20584557 [TBL] [Abstract][Full Text] [Related]
7. The development of DNA-based quartz crystal microbalance integrated with isothermal DNA amplification system for human papillomavirus type 58 detection. Prakrankamanant P; Leelayuwat C; Promptmas C; Limpaiboon T; Wanram S; Prasongdee P; Pientong C; Daduang J; Jearanaikoon P Biosens Bioelectron; 2013 Feb; 40(1):252-7. PubMed ID: 22959017 [TBL] [Abstract][Full Text] [Related]
8. Technique for quantitative detection of specific DNA sequences using alternately binding quenching probe competitive assay combined with loop-mediated isothermal amplification. Tani H; Teramura T; Adachi K; Tsuneda S; Kurata S; Nakamura K; Kanagawa T; Noda N Anal Chem; 2007 Aug; 79(15):5608-13. PubMed ID: 17579496 [TBL] [Abstract][Full Text] [Related]
9. Microchamber array based DNA quantification and specific sequence detection from a single copy via PCR in nanoliter volumes. Matsubara Y; Kerman K; Kobayashi M; Yamamura S; Morita Y; Tamiya E Biosens Bioelectron; 2005 Feb; 20(8):1482-90. PubMed ID: 15626601 [TBL] [Abstract][Full Text] [Related]
10. Development and evaluation of reverse transcription-loop-mediated isothermal amplification assay for rapid and real-time detection of Japanese encephalitis virus. Parida MM; Santhosh SR; Dash PK; Tripathi NK; Saxena P; Ambuj S; Sahni AK; Lakshmana Rao PV; Morita K J Clin Microbiol; 2006 Nov; 44(11):4172-8. PubMed ID: 17005741 [TBL] [Abstract][Full Text] [Related]
11. Application of a loop-mediated isothermal amplification method for the detection of pathogenic Leptospira. Lin X; Chen Y; Lu Y; Yan J; Yan J Diagn Microbiol Infect Dis; 2009 Mar; 63(3):237-42. PubMed ID: 19070450 [TBL] [Abstract][Full Text] [Related]
12. A real-time microfluidic multiplex electrochemical loop-mediated isothermal amplification chip for differentiating bacteria. Luo J; Fang X; Ye D; Li H; Chen H; Zhang S; Kong J Biosens Bioelectron; 2014 Oct; 60():84-91. PubMed ID: 24787122 [TBL] [Abstract][Full Text] [Related]
13. Development and clinical validation of a loop-mediated isothermal amplification method for the rapid detection of Neisseria meningitidis. McKenna JP; Fairley DJ; Shields MD; Cosby SL; Wyatt DE; McCaughey C; Coyle PV Diagn Microbiol Infect Dis; 2011 Feb; 69(2):137-44. PubMed ID: 21251556 [TBL] [Abstract][Full Text] [Related]
14. Rapid detection of the cariogenic pathogens Streptococcus mutans and Streptococcus sobrinus using loop-mediated isothermal amplification. Nagashima S; Yoshida A; Ansai T; Watari H; Notomi T; Maki K; Takehara T Oral Microbiol Immunol; 2007 Dec; 22(6):361-8. PubMed ID: 17949337 [TBL] [Abstract][Full Text] [Related]
15. Sensitive quantification of Escherichia coli O157:H7, Salmonella enterica , and Campylobacter jejuni by combining stopped polymerase chain reaction with chemiluminescence flow-through DNA microarray analysis. Donhauser SC; Niessner R; Seidel M Anal Chem; 2011 Apr; 83(8):3153-60. PubMed ID: 21417213 [TBL] [Abstract][Full Text] [Related]
16. Development and evaluation of real-time loop-mediated isothermal amplification for hepatitis B virus DNA quantification: a new tool for HBV management. Cai T; Lou G; Yang J; Xu D; Meng Z J Clin Virol; 2008 Apr; 41(4):270-6. PubMed ID: 18296109 [TBL] [Abstract][Full Text] [Related]
17. Detection of periodontal pathogen Porphyromonas gingivalis by loop-mediated isothermal amplification method. Maeda H; Kokeguchi S; Fujimoto C; Tanimoto I; Yoshizumi W; Nishimura F; Takashiba S FEMS Immunol Med Microbiol; 2005 Feb; 43(2):233-9. PubMed ID: 15681153 [TBL] [Abstract][Full Text] [Related]
18. Loop-mediated isothermal amplification integrated on microfluidic chips for point-of-care quantitative detection of pathogens. Fang X; Liu Y; Kong J; Jiang X Anal Chem; 2010 Apr; 82(7):3002-6. PubMed ID: 20218572 [TBL] [Abstract][Full Text] [Related]
19. Evaluation of loop-mediated isothermal amplification for detection of Toxoplasma gondii in water samples and comparative findings by polymerase chain reaction and immunofluorescence test (IFT). Sotiriadou I; Karanis P Diagn Microbiol Infect Dis; 2008 Dec; 62(4):357-65. PubMed ID: 18715739 [TBL] [Abstract][Full Text] [Related]
20. [Establishment and application of loop-mediated isothermal amplification method for rapid detection]. Zhu SR; Wang ZG; Zhang Z; Lu YY; Mei LL; Zhan L Zhonghua Liu Xing Bing Xue Za Zhi; 2009 May; 30(5):481-5. PubMed ID: 19799145 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]