These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

637 related articles for article (PubMed ID: 21723703)

  • 1. Comparison of radiographic alignment of imageless computer-assisted surgery vs conventional instrumentation in primary total knee arthroplasty.
    Barrett WP; Mason JB; Moskal JT; Dalury DF; Oliashirazi A; Fisher DA
    J Arthroplasty; 2011 Dec; 26(8):1273-1284.e1. PubMed ID: 21723703
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Plain radiograph fails to reflect the alignment and advantages of navigation in total knee arthroplasty.
    Choi WC; Lee S; An JH; Kim D; Seong SC; Lee MC
    J Arthroplasty; 2011 Aug; 26(5):756-64. PubMed ID: 20875940
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accelerometer-Based and Computer-Assisted Navigation in Total Knee Arthroplasty: A Reduction in Mechanical Axis Outliers Does Not Lead to Improvement in Functional Outcomes or Quality of Life When Compared to Conventional Total Knee Arthroplasty.
    Goh GS; Liow MHL; Tay DK; Lo NN; Yeo SJ; Tan MH
    J Arthroplasty; 2018 Feb; 33(2):379-385. PubMed ID: 29054725
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Randomized trial of computer-assisted knee arthroplasty: impact on clinical and radiographic outcomes.
    Hiscox CM; Bohm ER; Turgeon TR; Hedden DR; Burnell CD
    J Arthroplasty; 2011 Dec; 26(8):1259-64. PubMed ID: 21592721
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Computer navigation for total knee arthroplasty achieves better postoperative alignment compared to conventional and patient-specific instrumentation in a low-volume setting.
    Suero EM; Lueke U; Stuebig T; Hawi N; Krettek C; Liodakis E
    Orthop Traumatol Surg Res; 2018 Nov; 104(7):971-975. PubMed ID: 29704634
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Radiographic analysis of a hand-held surgical navigation system for tibial resection in total knee arthroplasty.
    Nam D; Jerabek SA; Haughom B; Cross MB; Reinhardt KR; Mayman DJ
    J Arthroplasty; 2011 Dec; 26(8):1527-33. PubMed ID: 21397455
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Margin of error in alignment: a study undertaken when converting from conventional to computer-assisted total knee arthroplasty.
    Maniar RN; Johorey AC; Pujary CT; Yadava AN
    J Arthroplasty; 2011 Jan; 26(1):82-7. PubMed ID: 20171044
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Three-dimensional component alignment and functional outcome in computer-navigated total knee arthroplasty: a prospective, randomized study comparing two navigation systems.
    Harvie P; Sloan K; Beaver RJ
    J Arthroplasty; 2011 Dec; 26(8):1285-90. PubMed ID: 21316913
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Total knee arthroplasty in patients with Ranawat type-II valgus arthritic knee with a marked coronal femoral bowing deformity: comparison between computer-assisted surgery and intra-articular resection.
    Huang TW; Chuang PY; Lee CY; Lin SJ; Huang KC; Shen SH; Tsai YH; Lee MS; Hsu RW
    J Orthop Surg Res; 2016 Aug; 11(1):88. PubMed ID: 27488841
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Differences in component and limb alignment between computer-assisted and conventional surgery total knee arthroplasty.
    Huang TW; Peng KT; Huang KC; Lee MS; Hsu RW
    Knee Surg Sports Traumatol Arthrosc; 2014 Dec; 22(12):2954-61. PubMed ID: 25331655
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Differences in measurement of lower limb alignment among different registration methods of navigation and radiographs in TKA using the OrthoPilot system.
    Seo SS; Seo JH; Sohn MW; Kim YJ
    Orthopedics; 2012 Oct; 35(10 Suppl):50-5. PubMed ID: 23026253
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Does accurate anatomical alignment result in better function and quality of life? Comparing conventional and computer-assisted total knee arthroplasty.
    Choong PF; Dowsey MM; Stoney JD
    J Arthroplasty; 2009 Jun; 24(4):560-9. PubMed ID: 18534397
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Favourable alignment outcomes with MRI-based patient-specific instruments in total knee arthroplasty.
    Schotanus MGM; Thijs E; Heijmans M; Vos R; Kort NP
    Knee Surg Sports Traumatol Arthrosc; 2018 Sep; 26(9):2659-2668. PubMed ID: 28698929
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Total knee arthroplasty with patient-specific instruments improves function and restores limb alignment in patients with extra-articular deformity.
    Thienpont E; Paternostre F; Pietsch M; Hafez M; Howell S
    Knee; 2013 Dec; 20(6):407-11. PubMed ID: 23899651
    [TBL] [Abstract][Full Text] [Related]  

  • 15. 2017 Chitranjan S. Ranawat Award: Does Computer Navigation in Knee Arthroplasty Improve Functional Outcomes in Young Patients? A Randomized Study.
    Kim YH; Park JW; Kim JS
    Clin Orthop Relat Res; 2018 Jan; 476(1):6-15. PubMed ID: 29389753
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Functional outcome and alignment in computer-assisted and conventionally operated total knee replacements: a multicentre parallel-group randomised controlled trial.
    Gøthesen O; Espehaug B; Havelin LI; Petursson G; Hallan G; Strøm E; Dyrhovden G; Furnes O
    Bone Joint J; 2014 May; 96-B(5):609-18. PubMed ID: 24788494
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Total Knee Arthroplasty in Patients With Extra-Articular Deformity: Restoration of Mechanical Alignment Using Accelerometer-Based Navigation System.
    Matassi F; Cozzi Lepri A; Innocenti M; Zanna L; Civinini R; Innocenti M
    J Arthroplasty; 2019 Apr; 34(4):676-681. PubMed ID: 30685259
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Computer navigated versus conventional total knee arthroplasty.
    Tolk JJ; Koot HW; Janssen RP
    J Knee Surg; 2012 Sep; 25(4):347-52. PubMed ID: 23150163
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Tibial component alignment after total knee arthroplasty with intramedullary instrumentation: a prospective analysis.
    Talmo CT; Cooper AJ; Wuerz T; Lang JE; Bono JV
    J Arthroplasty; 2010 Dec; 25(8):1209-15. PubMed ID: 19879723
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Radiographic results of an accelerometer-based, handheld surgical navigation system for the tibial resection in total knee arthroplasty.
    Nam D; Cross M; Deshmane P; Jerabek S; Kang M; Mayman DJ
    Orthopedics; 2011 Oct; 34(10):e615-21. PubMed ID: 21956055
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 32.