These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

358 related articles for article (PubMed ID: 21726718)

  • 1. Comparative study of 2-hydroxy propyl beta cyclodextrin and calixarene as ionophores in potentiometric ion-selective electrodes for neostigmine bromide.
    El-Kosasy AM; Nebsen M; Abd El-Rahman MK; Salem MY; El-Bardicy MG
    Talanta; 2011 Aug; 85(2):913-8. PubMed ID: 21726718
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Ion-Selective Electrodes for the Potentiometric Determination of Pramoxine HCl Using Different Ionophores.
    Ramadan NK; Merey HA
    Acta Chim Slov; 2012 Dec; 59(4):870-8. PubMed ID: 24061370
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Novel potentiometric application for the determination of pantoprazole sodium and itopride hydrochloride in their pure and combined dosage form.
    Ragab MT; Abd El-Rahman MK; Ramadan NK; El-Ragehy NA; El-Zeany BA
    Talanta; 2015 Jun; 138():28-35. PubMed ID: 25863367
    [TBL] [Abstract][Full Text] [Related]  

  • 4. New ionophores for vitamin B1 and vitamin B6 potentiometric sensors for multivitaminic control.
    Pires AR; Araújo AN; Montenegro MC; Chocholous P; Solich P
    J Pharm Biomed Anal; 2008 Mar; 46(4):683-91. PubMed ID: 18207686
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Modified carbon paste sensor for the potentiometric determination of neostigmine bromide in pharmaceutical formulations, human plasma and urine.
    Khorshid AF; Issa YM
    Biosens Bioelectron; 2014 Jan; 51():143-9. PubMed ID: 23948245
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Microsized graphite sensors for potentiometric determination of cyclobenzaprine hydrochloride in pure powder, tablets, and plasma.
    Ramadan NK; Zaazaa HE; Merey HA
    J AOAC Int; 2011; 94(6):1807-14. PubMed ID: 22320088
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Membrane electrodes for the determination of pyridostigmine bromide.
    El-Kosasy AM; Salem MY; El-Bardicy MG; Abd El-Rahman MK
    J AOAC Int; 2009; 92(6):1631-8. PubMed ID: 20166579
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Enhancing the Sustainability of Eco-Friendly Potentiometric Ion-Selective Electrodes for Stability-Indicating Measurement of Ethamsylate: Application in Bulk and Pharmaceutical Formulations.
    Monir HH; Mohamed HA; Badawy AM; Nebsen M; Nessim CK
    J AOAC Int; 2024 Jul; 107(4):549-557. PubMed ID: 38627224
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determination of pyridoxine hydrochloride in pharmaceutical preparations by calixarene based potentiometric sensor.
    Vaze VD; Srivastava AK
    J Pharm Biomed Anal; 2008 May; 47(1):177-82. PubMed ID: 18243627
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cyclodextrin-based potentiometric sensors for midazolam and diazepam.
    Amorim CG; Araújo AN; Montenegro MC; Silva VL
    J Pharm Biomed Anal; 2008 Dec; 48(4):1064-9. PubMed ID: 18835673
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Miniaturized ionophore-based potentiometric sensors for the flow-injection determination of metformin in pharmaceutical formulations and biological fluids.
    Khaled E; Kamel MS; Hassan HN; Abd El-Alim SH; Aboul-Enein HY
    Analyst; 2012 Dec; 137(23):5680-7. PubMed ID: 23050261
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Selective potentiometric determination of zolpidem hemitartrate in tablets and biological fluids by using polymeric membrane electrodes.
    Kelani KM
    J AOAC Int; 2004; 87(6):1309-18. PubMed ID: 15675441
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ion selective phosphotungestate and beta-cyclodextrin based membrane electrodes for stability-indicating determination of midodrine hydrochloride.
    Elzanfaly ES; Zaazaa HE; Merey HA
    Acta Chim Slov; 2013; 60(2):256-62. PubMed ID: 23878928
    [TBL] [Abstract][Full Text] [Related]  

  • 14. New potentiometric sensors based on selective recognition sites for determination of ephedrine in some pharmaceuticals and biological fluids.
    Hassan SS; Kamel AH; Abd El-Naby H
    Talanta; 2013 Jan; 103():330-6. PubMed ID: 23200395
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of a pH sensing membrane electrode based on a new calix[4]arene derivative.
    Kormalı Ertürün HE; Demirel Özel A; Sayın S; Yılmaz M; Kılıç E
    Talanta; 2015 Jan; 132():669-75. PubMed ID: 25476362
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ionophore-Based Polymeric Sensors for Potentiometric Assay of the Anticancer Drug Gemcitabine in Pharmaceutical Formulation: A Comparative Study.
    Mostafa GAE; El-Tohamy MF; Ali EA; Al-Salahi R; Attwa MW; AlRabiah H
    Molecules; 2023 Nov; 28(22):. PubMed ID: 38005274
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Sulfadiazine-selective determination in aquaculture environment: selective potentiometric transduction by neutral or charged ionophores.
    Almeida SA; Heitor AM; Montenegro MC; Sales MG
    Talanta; 2011 Sep; 85(3):1508-16. PubMed ID: 21807216
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparative study of β-cyclodextrin, γ-cyclodextrin and 4-
    Alrabiah H; Aljohar HI; Bakheit AH; Homoda AM; Mostafa GA
    Drug Des Devel Ther; 2019; 13():2283-2293. PubMed ID: 31371922
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Analytical Eco-Scale for Assessing the Greenness of a Developed Potentiometric Method for Lomefloxacin Hydrochloride Determination in its Different Dosage Forms, Plasma, and Dissolution Medium.
    Boltia SA; Soudi AT; Elzanfaly ES; Zaazaa HE
    J AOAC Int; 2019 May; 102(3):794-800. PubMed ID: 30446018
    [No Abstract]   [Full Text] [Related]  

  • 20. Membrane electrodes for the determination of glutathione.
    El-Kosasy AM; Shehata MA; Hassan NY; Fayed AS; El-Zeany BA
    Talanta; 2005 Apr; 66(3):746-54. PubMed ID: 18970048
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.