173 related articles for article (PubMed ID: 21729285)
21. The case of an explanted 16-year-old mitral Carpentier-Edwards pericardial bioprosthesis.
Murayama H; Watanabe T; Yano T; Kida N; Hatano Y; Ohara K; Kobayashi A
J Artif Organs; 2006; 9(4):259-62. PubMed ID: 17171405
[TBL] [Abstract][Full Text] [Related]
22. The Carpentier-Edwards Perimount Magna mitral valve bioprosthesis: intermediate-term efficacy and durability.
Loor G; Schuster A; Cruz V; Rafael A; Stewart WJ; Diaz J; McCurry K
J Cardiothorac Surg; 2016 Jan; 11():20. PubMed ID: 26818795
[TBL] [Abstract][Full Text] [Related]
23. The Carpentier-Edwards standard porcine bioprosthesis. A first-generation tissue valve with excellent long-term clinical performance.
Jamieson WR; Allen P; Miyagishima RT; Gerein AN; Munro AI; Burr LH; Tyers GF
J Thorac Cardiovasc Surg; 1990 Mar; 99(3):543-61. PubMed ID: 2308373
[TBL] [Abstract][Full Text] [Related]
24. A 25-year experience with Carpentier-Edwards Perimount in the mitral position.
Ayegnon KG; Aupart M; Bourguignon T; Mirza A; May MA; Marchand M
Asian Cardiovasc Thorac Ann; 2011 Feb; 19(1):14-9. PubMed ID: 21357312
[TBL] [Abstract][Full Text] [Related]
25. Comparison of reoperation findings of the Carpentier-Edwards (standard) bioprosthesis and the St Jude bioimplant (formerly Liotta) in the mitral position.
Yamak B; Ozsöyler ; Ulus AT; Kiziltepe U; Katircioğlu SF; Taşdemir O
Cardiovasc Surg; 1999 Dec; 7(7):730-4. PubMed ID: 10639048
[TBL] [Abstract][Full Text] [Related]
26. Trans-catheter valve-in-valve implantation: in vitro hydrodynamic performance of the SAPIEN+cloth trans-catheter heart valve in the Carpentier-Edwards Perimount valves.
Walther T; Dehdashtian MM; Khanna R; Young E; Goldbrunner PJ; Lee W
Eur J Cardiothorac Surg; 2011 Nov; 40(5):1120-6. PubMed ID: 21466959
[TBL] [Abstract][Full Text] [Related]
27. Carpentier-Edwards supraannular porcine bioprosthesis evaluation over 15 years.
Jamieson WR; Ling H; Burr LH; Fradet GJ; Miyagishima RT; Janusz MT; Lichtenstein SV
Ann Thorac Surg; 1998 Dec; 66(6 Suppl):S49-52. PubMed ID: 9930416
[TBL] [Abstract][Full Text] [Related]
28. Postoperative Migration of an Edwards-SAPIEN XT Mitral Valve-in-Valve Treated With Direct Vision Implantation During Beating-Heart Bypass.
Mick SL; Roselli EE; Kapadia S; Tuzcu EM; Krishnaswamy A; Svensson LG
Ann Thorac Surg; 2016 Mar; 101(3):1182-5. PubMed ID: 26897205
[TBL] [Abstract][Full Text] [Related]
29. Commissural fusion as etiology of bioprosthetic mitral stenosis in a patient with rheumatic heart disease.
Vallabhaneni S; Matka M; Olenchock S; Sarnoski C; Longo S; Shirani J
Echocardiography; 2020 Apr; 37(4):637-640. PubMed ID: 32181512
[TBL] [Abstract][Full Text] [Related]
30. Persistent mitral stenosis after mitral valve replacement with a Carpentier-Edwards bioprosthesis.
Lundy EF; Vazales BE; Bonchek LL; Burlingame MW
J Thorac Cardiovasc Surg; 1990 Jun; 99(6):1114. PubMed ID: 2359331
[No Abstract] [Full Text] [Related]
31. Very long-term outcomes of the Carpentier-Edwards Perimount valve in aortic position.
Bourguignon T; Bouquiaux-Stablo AL; Candolfi P; Mirza A; Loardi C; May MA; El-Khoury R; Marchand M; Aupart M
Ann Thorac Surg; 2015 Mar; 99(3):831-7. PubMed ID: 25583467
[TBL] [Abstract][Full Text] [Related]
32. Excellent durability of a Starr-Edwards mitral caged-ball-valve prosthesis over 34 years.
Mariscalco G; Cozzi GP; Gherli R; Sala A
J Card Surg; 2011 Jan; 26(1):72. PubMed ID: 21073526
[No Abstract] [Full Text] [Related]
33. Aortic and mitral valve replacement with the Carpentier-Edwards pericardial bioprosthesis: 10-year results.
Murakami T; Eishi K; Nakano S; Kobayashi J; Sasako Y; Isobe F; Kosakai Y; Kito Y; Kawashima Y
J Heart Valve Dis; 1996 Jan; 5(1):45-9. PubMed ID: 8834725
[TBL] [Abstract][Full Text] [Related]
34. Twelve-year experience with Carpentier-Edwards PERIMOUNT pericardial valve in the mitral position: a multicenter study.
Marchand M; Aupart M; Norton R; Goldsmith IR; Pelletier C; Pellerin M; Dubiel T; Daenen W; Casselman F; Holden M; David TE; Ryba EA
J Heart Valve Dis; 1998 May; 7(3):292-8. PubMed ID: 9651842
[TBL] [Abstract][Full Text] [Related]
35. Immediate structural valve deterioration of 27-mm Carpentier-Edwards aortic pericardial bioprosthesis.
Fleisher AG; Lafaro RJ; Moggio RA
Ann Thorac Surg; 2004 Apr; 77(4):1443-5. PubMed ID: 15063289
[TBL] [Abstract][Full Text] [Related]
36. [A case report: Carpentier-Edwards porcine bioprosthesis malfunction due to the stent dehiscence at 17 years after the implantation in the mitral position].
Hayashi K; Nakano H; Sakamoto T; Okamura H
Kyobu Geka; 2000 Jan; 53(1):79-82. PubMed ID: 10639799
[TBL] [Abstract][Full Text] [Related]
37. The Carpentier-Edwards pericardial bioprosthesis: clinical experience with 600 patients.
Pelletier LC; Carrier M; Leclerc Y; Dyrda I
Ann Thorac Surg; 1995 Aug; 60(2 Suppl):S297-302. PubMed ID: 7646176
[TBL] [Abstract][Full Text] [Related]
38. Missing leaflet: a rare cause of structural deterioration of a bovine pericardial aortic bioprosthesis-report of a case.
Nakamura Y; Fujiwara Y; Shiraya S; Saiki M; Harada S; Kishimoto Y; Onohara T; Otsuki Y; Nishimura M
Surg Today; 2014 Sep; 44(9):1757-9. PubMed ID: 23700244
[TBL] [Abstract][Full Text] [Related]
39. Acute thrombosis of bioprosthetic mitral valve.
Kwon JT; Jung TE; Lee DH
J Cardiothorac Surg; 2013 Aug; 8():185. PubMed ID: 23981275
[TBL] [Abstract][Full Text] [Related]
40. Patient-prosthesis mismatch in patients undergoing bioprosthetic aortic valve implantation increases risk of reoperation for structural valve deterioration.
Urso S; Calderón P; Sadaba R; Mahillo I; Tuñón J; Aldamiz G; Fraile J
J Card Surg; 2014 Jul; 29(4):439-44. PubMed ID: 24773571
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]