These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

204 related articles for article (PubMed ID: 21730933)

  • 1. Modification of endotracheal intubation using AirwayScope™ videolaryngoscope for straight reinforced tubes.
    Minonishi T; Kinoshita H; Hirayama M; Hatakeyama N; Matsuda N
    Minerva Anestesiol; 2011 Aug; 77(8):850-1. PubMed ID: 21730933
    [No Abstract]   [Full Text] [Related]  

  • 2. Tracheal intubation with the AirwayScope videolaryngoscope using straight vs curved reinforced tubes.
    Minonishi T; Kinoshita H; Tange K; Hatakeyama N; Matsuda N; Azma T; Hatano Y
    Can J Anaesth; 2010 Jan; 57(1):92-3. PubMed ID: 19866244
    [No Abstract]   [Full Text] [Related]  

  • 3. Tracheal intubation with a camera embedded in the tube tip (Vivasight(™) ).
    Huitink JM; Koopman EM; Bouwman RA; Craenen A; Verwoert M; Krage R; Visser IE; Erwteman M; van Groeningen D; Tijink R; Schauer A
    Anaesthesia; 2013 Jan; 68(1):74-8. PubMed ID: 23121322
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comments on tracheal intubation using the mobile C-MAC videolaryngoscope or direct laryngoscopy in patients with a simulated difficult airway.
    Xue FS; Yuan YJ; Wang Q; Xiong J; Liao C
    Minerva Anestesiol; 2010 Dec; 76(12):1098-9; author reply 1100. PubMed ID: 21102397
    [No Abstract]   [Full Text] [Related]  

  • 5. Intubation of the morbidly obese patient: GlideScope(®) vs. Fastrach™.
    Ydemann M; Rovsing L; Lindekaer AL; Olsen KS
    Acta Anaesthesiol Scand; 2012 Jul; 56(6):755-61. PubMed ID: 22524487
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Performance of indirect and direct laryngoscopy for endotracheal intubation in suspected difficult airways.
    Meng FM; Zhang JQ; Chang EQ; Xue FS
    Minerva Anestesiol; 2013 Apr; 79(4):445-6. PubMed ID: 23174926
    [No Abstract]   [Full Text] [Related]  

  • 7. Simulation based training of airway management with Macintosh blade and Glidescope video laryngoscope.
    Latif RK; Akca O
    Minerva Anestesiol; 2011 Jan; 77(1):1-3. PubMed ID: 21273961
    [No Abstract]   [Full Text] [Related]  

  • 8. The changing scope of difficult airway management.
    Wanderer JP; Ehrenfeld JM; Sandberg WS; Epstein RH
    Can J Anaesth; 2013 Oct; 60(10):1022-4. PubMed ID: 23897492
    [No Abstract]   [Full Text] [Related]  

  • 9. Answer to "performance of indirect and direct laryngoscopy for endotracheal intubation in suspected difficult airways".
    Serocki G; Cavus E
    Minerva Anestesiol; 2013 Apr; 79(4):447-8. PubMed ID: 23370126
    [No Abstract]   [Full Text] [Related]  

  • 10. A double-curved tube for McGrath® MAC videolaryngoscope-guided tracheal intubation.
    Tsunoda N; Asai T
    Br J Anaesth; 2022 Jan; 128(1):e14-e16. PubMed ID: 34742541
    [No Abstract]   [Full Text] [Related]  

  • 11. [Airwaymanagement: video-assisted airway management].
    Cavus E; Bein B; Dörges V
    Anasthesiol Intensivmed Notfallmed Schmerzther; 2011 Sep; 46(9):588-96. PubMed ID: 21894592
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Difficult tracheal tube passage and subglottic airway injury during intubation with the GlideScope
    Su K; Gao X; Xue FS; Ding GN; Zhang Y; Tian M
    Anaesthesia; 2017 Apr; 72(4):504-511. PubMed ID: 27995626
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Combination of videolaryngoscope and tracheal tube introducer for difficult infant airway management.
    Ohchi F; Komasawa N; Imagawa K; Minami T
    J Clin Anesth; 2016 Sep; 33():498-9. PubMed ID: 26493718
    [No Abstract]   [Full Text] [Related]  

  • 14. Tracheal intubation with a camera embedded in the tube tip.
    Curtis R
    Anaesthesia; 2013 Apr; 68(4):428. PubMed ID: 23488846
    [No Abstract]   [Full Text] [Related]  

  • 15. A reply.
    Huitink JM
    Anaesthesia; 2013 Apr; 68(4):429. PubMed ID: 23488848
    [No Abstract]   [Full Text] [Related]  

  • 16. Postoperative laryngeal morbidity and intubating conditions using the McGRATH™ MAC videolaryngoscope with or without neuromuscular blockade: a randomised, double-blind, non-inferiority trial.
    Nakanishi T; Yoshimura M; Sakamoto S; Toriumi T
    Anaesthesia; 2018 Aug; 73(8):990-996. PubMed ID: 29727011
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new twist in the pediatric difficult airway.
    Lillie EM; Harding L; Thomas M
    Paediatr Anaesth; 2015 Apr; 25(4):428-30. PubMed ID: 25267583
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of standard polyvinyl chloride tracheal tubes and straight reinforced tracheal tubes for tracheal intubation through different sizes of the Airtraq laryngoscope in anesthetized and paralyzed patients: a randomized prospective study.
    Dimitriou VK; Zogogiannis ID; Douma AK; Pentilas ND; Liotiri DG; Wachtel MS; Karakitsos D
    Anesthesiology; 2009 Dec; 111(6):1265-70. PubMed ID: 19934870
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Clinical relevance of issues concerning direct and indirect laryngoscopy.
    Caldiroli D; Cortellazzi P
    Minerva Anestesiol; 2013 Jun; 79(6):702. PubMed ID: 23370128
    [No Abstract]   [Full Text] [Related]  

  • 20. Use of the new Airtraq "Airtraq AVANT" in clinical settings.
    Ueshima H; Kitamura A
    J Clin Anesth; 2015 Aug; 27(5):441-2. PubMed ID: 25817338
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 11.