These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

259 related articles for article (PubMed ID: 21733461)

  • 1. The fate of syndesmotic screws.
    Stuart K; Panchbhavi VK
    Foot Ankle Int; 2011 May; 32(5):S519-25. PubMed ID: 21733461
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fate of the syndesmotic screw--Search for a prudent solution.
    Kaftandziev I; Spasov M; Trpeski S; Zafirova-Ivanovska B; Bakota B
    Injury; 2015 Nov; 46 Suppl 6():S125-9. PubMed ID: 26582218
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Fate of the Fixed Syndesmosis Over Time.
    Gennis E; Koenig S; Rodericks D; Otlans P; Tornetta P
    Foot Ankle Int; 2015 Oct; 36(10):1202-8. PubMed ID: 26041545
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The radiographic fate of the syndesmosis after trans-syndesmotic screw removal in displaced ankle fractures.
    Jordan TH; Talarico RH; Schuberth JM
    J Foot Ankle Surg; 2011; 50(4):407-12. PubMed ID: 21596590
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Technical aspects of the syndesmotic screw and their effect on functional outcome following acute distal tibiofibular syndesmosis injury.
    Schepers T; van der Linden H; van Lieshout EM; Niesten DD; van der Elst M
    Injury; 2014 Apr; 45(4):775-9. PubMed ID: 24139172
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Functional and radiographic results of patients with syndesmotic screw fixation: implications for screw removal.
    Manjoo A; Sanders DW; Tieszer C; MacLeod MD
    J Orthop Trauma; 2010 Jan; 24(1):2-6. PubMed ID: 20035170
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Compression screw fixation of the syndesmosis.
    Darwish HH; Glisson RR; DeOrio JK
    Foot Ankle Int; 2012 Oct; 33(10):893-9. PubMed ID: 23050715
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Syndesmotic Fixation Utilizing a Novel Screw: A Retrospective Case Series Reporting Early Clinical and Radiographic Outcomes.
    Stenquist D; Velasco BT; Cronin PK; Briceño J; Miller CP; Riedel MD; Kwon JY
    Foot Ankle Spec; 2020 Oct; 13(5):397-403. PubMed ID: 31353946
    [No Abstract]   [Full Text] [Related]  

  • 9. Arthroscopically measured syndesmotic stability after screw vs. suture button fixation in a cadaveric model.
    Lubberts B; Vopat BG; Wolf JC; Longo UG; DiGiovanni CW; Guss D
    Injury; 2017 Nov; 48(11):2433-2437. PubMed ID: 28899558
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A prospective randomised study comparing TightRope and syndesmotic screw fixation for accuracy and maintenance of syndesmotic reduction assessed with bilateral computed tomography.
    Kortekangas T; Savola O; Flinkkilä T; Lepojärvi S; Nortunen S; Ohtonen P; Katisko J; Pakarinen H
    Injury; 2015; 46(6):1119-26. PubMed ID: 25769201
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Syndesmosis fixation: a comparison of three and four cortices of screw fixation without hardware removal.
    Moore JA; Shank JR; Morgan SJ; Smith WR
    Foot Ankle Int; 2006 Aug; 27(8):567-72. PubMed ID: 16919207
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of suture button fixation and syndesmotic screw fixation in the treatment of distal tibiofibular syndesmosis injury: A systematic review and meta-analysis.
    Xie L; Xie H; Wang J; Chen C; Zhang C; Chen H; Zheng W
    Int J Surg; 2018 Dec; 60():120-131. PubMed ID: 30439535
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Removal of Hardware After Syndesmotic Screw Fixation: A Systematic Literature Review.
    Walley KC; Hofmann KJ; Velasco BT; Kwon JY
    Foot Ankle Spec; 2017 Jun; 10(3):252-257. PubMed ID: 28027655
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Is the standard retention of syndesmotic positioning screws after ankle fracture fixation safe and feasible? A retrospective cohort study in 140 consecutive patients at a North American trauma centre].
    Weckbach S; Hahnhaussen J; Losacco JT; Gebhard F; Stahel PF
    Z Orthop Unfall; 2014 Dec; 152(6):554-7. PubMed ID: 25531514
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of Reduction Accuracy of Suture-Button and Screw Fixation Techniques for Syndesmotic Injuries.
    Kocadal O; Yucel M; Pepe M; Aksahin E; Aktekin CN
    Foot Ankle Int; 2016 Dec; 37(12):1317-1325. PubMed ID: 27535086
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A systematic review of suture-button versus syndesmotic screw in the treatment of distal tibiofibular syndesmosis injury.
    Zhang P; Liang Y; He J; Fang Y; Chen P; Wang J
    BMC Musculoskelet Disord; 2017 Jul; 18(1):286. PubMed ID: 28676078
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Overtightening of the syndesmosis revisited and the effect of syndesmotic malreduction on ankle dorsiflexion.
    Gonzalez T; Egan J; Ghorbanhoseini M; Blais M; Lechtig A; Velasco B; Nazarian A; Kwon JY
    Injury; 2017 Jun; 48(6):1253-1257. PubMed ID: 28390687
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Functional outcomes following syndesmotic fixation: A comparison of screws retained in situ versus routine removal - Is it really necessary?
    Tucker A; Street J; Kealey D; McDonald S; Stevenson M
    Injury; 2013 Dec; 44(12):1880-4. PubMed ID: 24021584
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Screw fixation of the syndesmosis: a cadaver model comparing stainless steel and titanium screws and three and four cortical fixation.
    Beumer A; Campo MM; Niesing R; Day J; Kleinrensink GJ; Swierstra BA
    Injury; 2005 Jan; 36(1):60-4. PubMed ID: 15589915
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Injuries to the ankle syndesmosis.
    Van Heest TJ; Lafferty PM
    J Bone Joint Surg Am; 2014 Apr; 96(7):603-13. PubMed ID: 24695928
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.