These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

322 related articles for article (PubMed ID: 21736862)

  • 1. Inlay-retained zirconia fixed dental prostheses: modified designs for a completely adhesive approach.
    Monaco C; Cardelli P; Ozcan M
    J Can Dent Assoc; 2011; 77():b86. PubMed ID: 21736862
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Inlay-retained zirconia fixed dental prosthesis: clinical and laboratory procedures.
    Monaco C; Cardelli P; Bolognesi M; Scotti R; Ozcan M
    Eur J Esthet Dent; 2012; 7(1):48-60. PubMed ID: 22319764
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fracture strength of prefabricated all-ceramic posterior inlay-retained fixed dental prostheses.
    Mehl C; Ludwig K; Steiner M; Kern M
    Dent Mater; 2010 Jan; 26(1):67-75. PubMed ID: 19836829
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Inlay-retained cantilever fixed dental prostheses to substitute a single premolar: impact of zirconia framework design after dynamic loading.
    Shahin R; Tannous F; Kern M
    Eur J Oral Sci; 2014 Aug; 122(4):310-6. PubMed ID: 24910293
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Zirconia ceramic inlay-retained fixed dental prostheses - first clinical results with a new design.
    Abou Tara M; Eschbach S; Wolfart S; Kern M
    J Dent; 2011 Mar; 39(3):208-11. PubMed ID: 21185905
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Load-bearing capacity of all-ceramic posterior inlay-retained fixed dental prostheses.
    Puschmann D; Wolfart S; Ludwig K; Kern M
    Eur J Oral Sci; 2009 Jun; 117(3):312-8. PubMed ID: 19583761
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fracture behaviour of zirconia ceramic cantilever fixed dental prostheses in vitro.
    Gabbert O; Ohlmann B; Schmitter M; Gilde H; Ruef T; Rammelsberg P
    Acta Odontol Scand; 2008 Aug; 66(4):200-6. PubMed ID: 18622828
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Veneered zirconia inlay-retained fixed dental prostheses: 10-Year results from a prospective clinical study.
    Rathmann F; Bömicke W; Rammelsberg P; Ohlmann B
    J Dent; 2017 Sep; 64():68-72. PubMed ID: 28647157
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Marginal adaptation of 1 fiber-reinforced composite and 2 all-ceramic inlay fixed partial denture systems.
    Monaco C; Krejci I; Bortolotto T; Perakis N; Ferrari M; Scotti R
    Int J Prosthodont; 2006; 19(4):373-82. PubMed ID: 16900821
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Metal-free inlay-retained fixed partial dentures.
    Edelhoff D; Spiekermann H; Yildirim M
    Quintessence Int; 2001 Apr; 32(4):269-81. PubMed ID: 12066646
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Five-year clinical outcome of posterior zirconia ceramic inlay-retained FDPs with a modified design.
    Chaar MS; Kern M
    J Dent; 2015 Dec; 43(12):1411-5. PubMed ID: 26561926
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fracture force of tooth-tooth- and implant-tooth-supported all-ceramic fixed partial dentures using titanium vs. customised zirconia implant abutments.
    Kolbeck C; Behr M; Rosentritt M; Handel G
    Clin Oral Implants Res; 2008 Oct; 19(10):1049-53. PubMed ID: 18707604
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of gingival ceramic veneer thickness on the fracture strength of zirconia-based fixed dental prostheses.
    Gabbert O; Ohlmann B; Schmitter M; Farhan D; Becker F; Rammelsberg P
    Am J Dent; 2010 Jun; 23(3):147-51. PubMed ID: 20718211
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Conservative and esthetic cast gold fixed partial dentures-inlay, onlay, and partial veneer retainers, custom composite pontics, and stress breakers: part II: utilization of additional retentive features and fabrication of custom pontic facings.
    Stevenson RG; Refela JA
    J Esthet Restor Dent; 2009; 21(6):375-84. PubMed ID: 20002923
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Passivity of fit of CAD/CAM and copy-milled frameworks, veneered frameworks, and anatomically contoured, zirconia ceramic, implant-supported fixed prostheses.
    Karl M; Graef F; Wichmann M; Krafft T
    J Prosthet Dent; 2012 Apr; 107(4):232-8. PubMed ID: 22475466
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The influence of support properties and complexity on fracture strength and fracture mode of all-ceramic fixed dental prostheses.
    Mahmood DJ; Linderoth EH; Vult Von Steyern P
    Acta Odontol Scand; 2011 Jul; 69(4):229-37. PubMed ID: 21231816
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Novel ceria-stabilized tetragonal zirconia/alumina nanocomposite as framework material for posterior fixed dental prostheses: preliminary results of a prospective case series at 1 year of function.
    Philipp A; Fischer J; Hämmerle CH; Sailer I
    Quintessence Int; 2010 Apr; 41(4):313-9. PubMed ID: 20305866
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A prospective evaluation of zirconia posterior fixed dental prostheses: three-year clinical results.
    Peláez J; Cogolludo PG; Serrano B; Lozano JF; Suárez MJ
    J Prosthet Dent; 2012 Jun; 107(6):373-9. PubMed ID: 22633593
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The all-ceramic, inlay supported fixed partial denture. Part 2. Fixed partial denture design: a finite element analysis.
    Thompson MC; Field CJ; Swain MV
    Aust Dent J; 2011 Sep; 56(3):302-11. PubMed ID: 21884147
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A prospective study of implant-supported full-arch yttria-stabilized tetragonal zirconia polycrystal mandibular fixed dental prostheses: three-year results.
    Larsson C; Vult von Steyern P; Nilner K
    Int J Prosthodont; 2010; 23(4):364-9. PubMed ID: 20617228
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.