BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 21737167)

  • 1. Postal dosimetry audit test for small photon beams.
    Espinosa Mdel M; Núñez L; Muñiz JL; Lagares JI; Embid M; Gómez-Ros JM
    Radiother Oncol; 2012 Jan; 102(1):135-41. PubMed ID: 21737167
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A methodology for TLD postal dosimetry audit of high-energy radiotherapy photon beams in non-reference conditions.
    Izewska J; Georg D; Bera P; Thwaites D; Arib M; Saravi M; Sergieva K; Li K; Yip FG; Mahant AK; Bulski W
    Radiother Oncol; 2007 Jul; 84(1):67-74. PubMed ID: 17628209
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Photon beam audits for radiation therapy clinics: a pilot mailed dosemeter study in Turkey.
    Yegingil Z; DeWerd LA; Davis SD; Hammer C; Kunugi K
    Radiat Prot Dosimetry; 2012 Jan; 148(2):249-57. PubMed ID: 21362695
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [The EQUAL-ESTRO external quality control laboratory in France].
    Roué A; Van Dam J; Dutreix A; Svensson H
    Cancer Radiother; 2004 Nov; 8 Suppl 1():S44-9. PubMed ID: 15679246
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development of a TLD mailed system for remote dosimetry audit for (192)Ir HDR and PDR sources.
    Roué A; Venselaar JL; Ferreira IH; Bridier A; Van Dam J
    Radiother Oncol; 2007 Apr; 83(1):86-93. PubMed ID: 17368842
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Remote auditing of radiotherapy facilities using optically stimulated luminescence dosimeters.
    Lye J; Dunn L; Kenny J; Lehmann J; Kron T; Oliver C; Butler D; Alves A; Johnston P; Franich R; Williams I
    Med Phys; 2014 Mar; 41(3):032102. PubMed ID: 24593737
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Feasibility study of glass dosimeter postal dosimetry audit of high-energy radiotherapy photon beams.
    Mizuno H; Kanai T; Kusano Y; Ko S; Ono M; Fukumura A; Abe K; Nishizawa K; Shimbo M; Sakata S; Ishikura S; Ikeda H
    Radiother Oncol; 2008 Feb; 86(2):258-63. PubMed ID: 18023489
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The use of a multipurpose phantom for mailed dosimetry checks of therapeutic photon beams: 'OPERA' (operational phantom for external radiotherapy audit).
    Swinnen A; Verstraete J; Huyskens D
    Radiother Oncol; 2002 Sep; 64(3):317-26. PubMed ID: 12242120
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Commissioning stereotactic radiosurgery beams using both experimental and theoretical methods.
    Ding GX; Duggan DM; Coffey CW
    Phys Med Biol; 2006 May; 51(10):2549-66. PubMed ID: 16675869
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Experimental verification of a commercial Monte Carlo-based dose calculation module for high-energy photon beams.
    Künzler T; Fotina I; Stock M; Georg D
    Phys Med Biol; 2009 Dec; 54(24):7363-77. PubMed ID: 19934489
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of doses calculated by the Monte Carlo method and measured by LiF TLD in the buildup region for a 60Co photon beam.
    Budanec M; Knezević Z; Bokulić T; Mrcela I; Vrtar M; Vekić B; Kusić Z
    Appl Radiat Isot; 2008 Dec; 66(12):1925-9. PubMed ID: 18541436
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Monte Carlo simulation of MOSFET detectors for high-energy photon beams using the PENELOPE code.
    Panettieri V; Duch MA; Jornet N; Ginjaume M; Carrasco P; Badal A; Ortega X; Ribas M
    Phys Med Biol; 2007 Jan; 52(1):303-16. PubMed ID: 17183143
    [TBL] [Abstract][Full Text] [Related]  

  • 13. AAA and PBC calculation accuracy in the surface build-up region in tangential beam treatments. Phantom and breast case study with the Monte Carlo code PENELOPE.
    Panettieri V; Barsoum P; Westermark M; Brualla L; Lax I
    Radiother Oncol; 2009 Oct; 93(1):94-101. PubMed ID: 19541380
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Monte Carlo simulation of correction factors for IAEA TLD holders.
    Hultqvist M; Fernández-Varea JM; Izewska J
    Phys Med Biol; 2010 Mar; 55(6):N161-6. PubMed ID: 20197601
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Thermoluminescent dosimeters (TLD) quality assurance network in the Czech Republic.
    Kroutilķková D; Novotný J; Judas L
    Radiother Oncol; 2003 Feb; 66(2):235-44. PubMed ID: 12648796
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Feasibility study of entrance in vivo dose measurements with mailed thermoluminescence detectors.
    Swinnen A; Verstraete J; Huyskens DP
    Radiother Oncol; 2004 Oct; 73(1):89-96. PubMed ID: 15465151
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Superficial dose distribution in breast for tangential radiation treatment, Monte Carlo evaluation of Eclipse algorithms in case of phantom and patient geometries.
    Chakarova R; Gustafsson M; Bäck A; Drugge N; Palm Å; Lindberg A; Berglund M
    Radiother Oncol; 2012 Jan; 102(1):102-7. PubMed ID: 21741719
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A thermoluminescent dosimetry postal dose inter-comparison of radiation therapy centres in Malaysia.
    Rassiah P; Ng KH; DeWerd LA; Kunugi K
    Australas Phys Eng Sci Med; 2004 Mar; 27(1):25-9. PubMed ID: 15156705
    [TBL] [Abstract][Full Text] [Related]  

  • 19. EPR dosimetry of radiotherapy photon beams in inhomogeneous media using alanine films.
    Osterås BH; Hole EO; Olsen DR; Malinen E
    Phys Med Biol; 2006 Dec; 51(24):6315-28. PubMed ID: 17148820
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dosimetry quality audit of high energy photon beams in greek radiotherapy centers.
    Hourdakis CJ; Boziari A
    Radiother Oncol; 2008 Apr; 87(1):132-41. PubMed ID: 18343514
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.