These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

227 related articles for article (PubMed ID: 21745431)

  • 1. Bismuth iodoform paraffin paste: a review.
    Crossland GJ; Bath AP
    J Laryngol Otol; 2011 Sep; 125(9):891-5. PubMed ID: 21745431
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Bismuth iodoform paraffin paste hypersensitivity reactions in mastoid cavities following isolation of mucosal lining: a series of 587 patients.
    Coulson CJ; Pothier DD; Lai P; Rutka JA
    J Laryngol Otol; 2012 Mar; 126(3):240-3. PubMed ID: 22234088
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bismuth iodoform paraffin paste: a review.
    Ladak A; Agrawal S
    J Laryngol Otol; 2013 May; 127(5):531. PubMed ID: 23534610
    [No Abstract]   [Full Text] [Related]  

  • 4. Bismuth iodoform paraffin paste: a review.
    Macdonald K; Farboud A; Jardine A
    J Laryngol Otol; 2012 Nov; 126(11):1192. PubMed ID: 22975071
    [No Abstract]   [Full Text] [Related]  

  • 5. Technical tutorial: How to pack a nose with bismuth iodoform paraffin paste gauze safely and effectively.
    Amen F; Pace-Balzan A
    Emerg Med J; 2009 Jan; 26(1):52. PubMed ID: 19104102
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dangers of bismuth iodoform paraffin paste.
    Farrell RW
    Lancet; 1994 Dec; 344(8937):1637-8. PubMed ID: 7984011
    [No Abstract]   [Full Text] [Related]  

  • 7. Re: The need to include BIPP reactions in routine consent: we should not be patching together patch tests for bismuth iodoform paraffin paste allergy.
    George A; Martinez Del Pero M; Moumoulidis L; Donnelly N; Jani P
    Clin Otolaryngol; 2008 Apr; 33(2):162-3. PubMed ID: 18429889
    [No Abstract]   [Full Text] [Related]  

  • 8. Should we still be using bismuth iodoform paraffin paste-impregnated gauze as an ear canal dressing following ear surgery?
    Ashraf N; Capper R
    Clin Otolaryngol; 2013 Aug; 38(4):357-60. PubMed ID: 23957551
    [No Abstract]   [Full Text] [Related]  

  • 9. Neurotoxicity Secondary to Bismuth Iodoform Paraffin Paste Packing in an Orbital Exenteration Cavity.
    Chen Y; Psaltis A; Curragh D; Selva D
    Ophthalmic Plast Reconstr Surg; 2018; 34(2):179-180. PubMed ID: 29517596
    [No Abstract]   [Full Text] [Related]  

  • 10. Bipp: a case of toxicity?
    Jones JA
    Oral Surg Oral Med Oral Pathol; 1990 Jun; 69(6):668-71. PubMed ID: 2356077
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Nasal packing for epistaxis: two methods compared.
    Saab M; Randall PE
    Eur J Emerg Med; 1997 Mar; 4(1):44. PubMed ID: 9152696
    [No Abstract]   [Full Text] [Related]  

  • 12. Severe iatrogenic bismuth poisoning with bismuth iodoform paraffin paste treated with DMPS chelation.
    Ovaska H; Wood DM; House I; Dargan PI; Jones AL; Murray S
    Clin Toxicol (Phila); 2008 Nov; 46(9):855-7. PubMed ID: 19003595
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A prospective randomized controlled trial comparing the use of merocel nasal tampons and BIPP in the control of acute epistaxis.
    Corbridge RJ; Djazaeri B; Hellier WP; Hadley J
    Clin Otolaryngol Allied Sci; 1995 Aug; 20(4):305-7. PubMed ID: 8548959
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Hypersensitive allergic reactions to bismuth-iodoform-paraffin paste following ear surgery.
    Lim PV; Hughes RG; Oates J
    J Laryngol Otol; 1998 Apr; 112(4):335-7. PubMed ID: 9659493
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Commonly used topical oral wound dressing materials in dental and surgical practice--a literature review.
    Freedman M; Stassen LF
    J Ir Dent Assoc; 2013; 59(4):190-5. PubMed ID: 24156211
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Avoidance of BIPP allergy hypersensitivity reactions following ear surgery.
    Bennett AM; Bartle J; Yung MW
    Clin Otolaryngol; 2008 Feb; 33(1):32-4. PubMed ID: 18302551
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Bismuth toxicity in patients treated with bismuth iodoform paraffin packs.
    Atwal A; Cousin GC
    Br J Oral Maxillofac Surg; 2016 Jan; 54(1):111-2. PubMed ID: 26608687
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Extradural application of bismuth iodoform paraffin paste causing relapsing bismuth encephalopathy: a case report with CT and MRI studies.
    Sharma RR; Cast IP; Redfern RM; O'Brien C
    J Neurol Neurosurg Psychiatry; 1994 Aug; 57(8):990-3. PubMed ID: 8057127
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dangers of bismuth iodoform paraffin paste.
    Roy PM; Harry P; Cailleux A; Allain P
    Lancet; 1994 Dec; 344(8938):1708. PubMed ID: 7864988
    [No Abstract]   [Full Text] [Related]  

  • 20. The need to include BIPP reactions in routine consent.
    Flook EP; Uddin FJ; Johnston MN
    Clin Otolaryngol; 2006 Apr; 31(2):165-6. PubMed ID: 16620344
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 12.