BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 21763057)

  • 1. Comparison of six different intubation aids for use while wearing CBRN-PPE: a manikin study.
    Castle N; Pillay Y; Spencer N
    Resuscitation; 2011 Dec; 82(12):1548-52. PubMed ID: 21763057
    [TBL] [Abstract][Full Text] [Related]  

  • 2. What is the optimal position of an intubator wearing CBRN-PPE when intubating on the floor: a manikin study.
    Castle N; Pillay Y; Spencer N
    Resuscitation; 2011 May; 82(5):588-92. PubMed ID: 21330043
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Insertion of six different supraglottic airway devices whilst wearing chemical, biological, radiation, nuclear-personal protective equipment: a manikin study.
    Castle N; Pillay Y; Spencer N
    Anaesthesia; 2011 Nov; 66(11):983-8. PubMed ID: 21883122
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Utility of the Pentax-AWS in performing tracheal intubation while wearing chemical, biological, radiation and nuclear personal protective equipment: a randomised crossover trial using a manikin.
    Shin DH; Choi PC; Na JU; Cho JH; Han SK
    Emerg Med J; 2013 Jul; 30(7):527-31. PubMed ID: 23765764
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A comparison of the I-gel supraglottic airway as a conduit for tracheal intubation with the intubating laryngeal mask airway: a manikin study.
    Michalek P; Donaldson W; Graham C; Hinds JD
    Resuscitation; 2010 Jan; 81(1):74-7. PubMed ID: 19926388
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Impact of chemical, biological, radiation, and nuclear personal protective equipment on the performance of low- and high-dexterity airway and vascular access skills.
    Castle N; Owen R; Hann M; Clark S; Reeves D; Gurney I
    Resuscitation; 2009 Nov; 80(11):1290-5. PubMed ID: 19709794
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Does wearing CBRN-PPE adversely affect the ability for clinicians to accurately, safely, and speedily draw up drugs?
    Castle N; Bowen J; Spencer N
    Clin Toxicol (Phila); 2010 Jul; 48(6):522-7. PubMed ID: 20550425
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A comparison of a fiberoptic stylet and a bougie as adjuncts to direct laryngoscopy in a manikin-simulated difficult airway.
    Kovacs G; Law JA; McCrossin C; Vu M; Leblanc D; Gao J
    Ann Emerg Med; 2007 Dec; 50(6):676-85. PubMed ID: 17681639
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of Miller and Airtraq laryngoscopes for orotracheal intubation by physicians wearing CBRN protective equipment during infant resuscitation: a randomized crossover simulation study.
    Claret PG; Asencio R; Rogier D; Roger C; Fournier P; Tran TA; Sebbane M; Bobbia X; Emmanuel de La Coussaye J
    Scand J Trauma Resusc Emerg Med; 2016 Mar; 24():35. PubMed ID: 27004945
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Tracheal intubation through the intubating laryngeal mask airway training on manikin: comparison of single use and reusable devices from the same manufacturer].
    Haardt V; Lenfant F; Cailliod R; Freysz M
    Ann Fr Anesth Reanim; 2008 Apr; 27(4):297-301. PubMed ID: 18375094
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Performance and skill retention of intubation by paramedics using seven different airway devices--a manikin study.
    Ruetzler K; Roessler B; Potura L; Priemayr A; Robak O; Schuster E; Frass M
    Resuscitation; 2011 May; 82(5):593-7. PubMed ID: 21353364
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Laryngoscopic versus intubating LMA guided tracheal intubation by novice users--a manikin study.
    Timmermann A; Russo SG; Crozier TA; Nickel EA; Kazmaier S; Eich C; Graf BM
    Resuscitation; 2007 Jun; 73(3):412-6. PubMed ID: 17343972
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of malleable stylet and reusable and disposable bougies by paramedics in a simulated difficult intubation.
    Gregory P; Woollard M; Lighton D; Munro G; Jenkinson E; Newcombe RG; O'Meara P; Hamilton L
    Anaesthesia; 2012 Apr; 67(4):371-6. PubMed ID: 22288931
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Does position of the patient adversely affect successful intubation whilst wearing CBRN-PPE?
    Castle N; Owen R; Clarke S; Hann M; Reeves D; Gurney I
    Resuscitation; 2010 Sep; 81(9):1166-71. PubMed ID: 20598428
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison between intubation through ILMA and Airtraq, in different non-conventional patient positions: a manikin study.
    Grosomanidis V; Amaniti E; Pourzitaki Ch; Fyntanidou V; Mouratidis K; Vasilakos D
    Emerg Med J; 2012 Jan; 29(1):32-6. PubMed ID: 21183521
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of a single-use intubating videoscope (Ambu aScope ™) in three airway training manikins for oral intubation, nasal intubation and intubation via three supraglottic airway devices.
    Scutt S; Clark N; Cook TM; Smith C; Christmas T; Coppel L; Crewdson K
    Anaesthesia; 2011 Apr; 66(4):293-9. PubMed ID: 21401543
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Bag-mask ventilation and direct laryngoscopy versus intubating laryngeal mask airway: a manikin study of hands-on times during cardiopulmonary resuscitation.
    Russo SG; Stradtmann C; Crozier TA; Ringer C; Helms HJ; Quintel M; Wiese CH
    Eur J Emerg Med; 2014 Jun; 21(3):189-94. PubMed ID: 23502213
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Assessment of the speed and ease of insertion of three supraglottic airway devices by paramedics: a manikin study.
    Castle N; Owen R; Hann M; Naidoo R; Reeves D
    Emerg Med J; 2010 Nov; 27(11):860-3. PubMed ID: 20515910
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A comparison of direct and indirect laryngoscopes and the ILMA in novice users: a manikin study.
    Maharaj CH; McDonnell JG; Harte BH; Laffey JG
    Anaesthesia; 2007 Nov; 62(11):1161-6. PubMed ID: 17924898
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Paramedic tracheal intubation using the intubating laryngeal mask airway.
    McCall MJ; Reeves M; Skinner M; Ginifer C; Myles P; Dalwood N
    Prehosp Emerg Care; 2008; 12(1):30-4. PubMed ID: 18189174
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.