201 related articles for article (PubMed ID: 21771934)
1. High kilovoltage digital exposure techniques and patient dosimetry.
Fauber TL; Cohen TF; Dempsey MC
Radiol Technol; 2011; 82(6):501-10. PubMed ID: 21771934
[TBL] [Abstract][Full Text] [Related]
2. Dual-energy cardiac imaging: an image quality and dose comparison for a flat-panel detector and x-ray image intensifier.
Ducote JL; Xu T; Molloi S
Phys Med Biol; 2007 Jan; 52(1):183-96. PubMed ID: 17183135
[TBL] [Abstract][Full Text] [Related]
3. Evaluation of two objective methods to optimize kVp and personnel exposure using a digital indirect flat panel detector and simulated veterinary patients.
Copple C; Robertson ID; Thrall DE; Samei E
Vet Radiol Ultrasound; 2013; 54(1):9-16. PubMed ID: 23293957
[TBL] [Abstract][Full Text] [Related]
4. Experimental investigation of the dose and image quality characteristics of a digital mammography imaging system.
Huda W; Sajewicz AM; Ogden KM; Dance DR
Med Phys; 2003 Mar; 30(3):442-8. PubMed ID: 12674245
[TBL] [Abstract][Full Text] [Related]
5. Optimization of chest radiographic imaging parameters: a comparison of image quality and entrance skin dose for digital chest radiography systems.
Sun Z; Lin C; Tyan Y; Ng KH
Clin Imaging; 2012; 36(4):279-86. PubMed ID: 22726965
[TBL] [Abstract][Full Text] [Related]
6. Chest radiography with a digital flat-panel detector: experimental receiver operating characteristic analysis.
Metz S; Damoser P; Hollweck R; Roggel R; Engelke C; Woertler K; Renger B; Rummeny EJ; Link TM
Radiology; 2005 Mar; 234(3):776-84. PubMed ID: 15734933
[TBL] [Abstract][Full Text] [Related]
7. Patient dosimetry and image quality in digital radiology from online audit of the X-ray system.
Vano E; Fernandez JM; Ten JI; Gonzalez L; Guibelalde E; Prieto C
Radiat Prot Dosimetry; 2005; 117(1-3):199-203. PubMed ID: 16461529
[TBL] [Abstract][Full Text] [Related]
8. Exposure variability and image quality in computed radiography.
Fauber TL
Radiol Technol; 2009; 80(3):209-15. PubMed ID: 19153197
[TBL] [Abstract][Full Text] [Related]
9. Copper Filtration and kVp: Effect on Entrance Skin Exposure.
Barba J; Culp M
Radiol Technol; 2015; 86(6):603-9. PubMed ID: 26199432
[TBL] [Abstract][Full Text] [Related]
10. Effect of radiographic techniques (kVp and mAs) on image quality and patient doses in digital subtraction angiography.
Gkanatsios NA; Huda W; Peters KR
Med Phys; 2002 Aug; 29(8):1643-50. PubMed ID: 12201409
[TBL] [Abstract][Full Text] [Related]
11. Flat-panel-detector chest radiography: effect of tube voltage on image quality.
Uffmann M; Neitzel U; Prokop M; Kabalan N; Weber M; Herold CJ; Schaefer-Prokop C
Radiology; 2005 May; 235(2):642-50. PubMed ID: 15858104
[TBL] [Abstract][Full Text] [Related]
12. [Reduction of patient exposure by the use of digital luminescence radiography].
Seifert H; Chapot C
J Radiol; 1999 Nov; 80(11):1555-60. PubMed ID: 10592912
[TBL] [Abstract][Full Text] [Related]
13. A factorial experiment on image quality and radiation dose.
Norrman E; Persliden J
Radiat Prot Dosimetry; 2005; 114(1-3):246-52. PubMed ID: 15933116
[TBL] [Abstract][Full Text] [Related]
14. Effects of radiographic techniques on the low-contrast detail detectability performance of digital radiography systems.
Alsleem H; U P; Mong KS; Davidson R
Radiol Technol; 2014; 85(6):614-22. PubMed ID: 25002641
[TBL] [Abstract][Full Text] [Related]
15. Reducing the radiation dose during excretory urography: flat-panel silicon x-ray detector versus computed radiography.
Zähringer M; Hesselmann V; Schulte O; Kamm KF; Braun W; Haupt G; Krug B; Lackner K
AJR Am J Roentgenol; 2003 Oct; 181(4):931-7. PubMed ID: 14500204
[TBL] [Abstract][Full Text] [Related]
16. Radiation dose reduction in direct digital panoramic radiography.
Gavala S; Donta C; Tsiklakis K; Boziari A; Kamenopoulou V; Stamatakis HC
Eur J Radiol; 2009 Jul; 71(1):42-8. PubMed ID: 18448296
[TBL] [Abstract][Full Text] [Related]
17. A reduction in radiographic exposure and image quality in film screen postero-anterior chest radiography.
Egbe NO; Egong EA; Ekpo EU; Inah GB
Niger J Med; 2012; 21(1):21-4. PubMed ID: 23301442
[TBL] [Abstract][Full Text] [Related]
18. Effect of dose metrics and radiation risk models when optimizing CT x-ray tube voltage.
Huda W; Ogden KM; Khorasani MR
Phys Med Biol; 2008 Sep; 53(17):4719-32. PubMed ID: 18695298
[TBL] [Abstract][Full Text] [Related]
19. Digital radiography of scoliosis with a scanning method: initial evaluation.
Geijer H; Beckman K; Jonsson B; Andersson T; Persliden J
Radiology; 2001 Feb; 218(2):402-10. PubMed ID: 11161153
[TBL] [Abstract][Full Text] [Related]
20. Analysis of image quality in digital chest imaging.
De Hauwere A; Bacher K; Smeets P; Verstraete K; Thierens H
Radiat Prot Dosimetry; 2005; 117(1-3):174-7. PubMed ID: 16461499
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]