These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

99 related articles for article (PubMed ID: 21776534)

  • 1. A microchip-based model wound with multiple types of cells.
    Xie Y; Zhang W; Wang L; Sun K; Sun Y; Jiang X
    Lab Chip; 2011 Sep; 11(17):2819-22. PubMed ID: 21776534
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development of a renal microchip for in vitro distal tubule models.
    Baudoin R; Griscom L; Monge M; Legallais C; Leclerc E
    Biotechnol Prog; 2007; 23(5):1245-53. PubMed ID: 17725364
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development of a microchip-based bioassay system using cultured cells.
    Goto M; Sato K; Murakami A; Tokeshi M; Kitamori T
    Anal Chem; 2005 Apr; 77(7):2125-31. PubMed ID: 15801746
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A multicellular spheroid array to realize spheroid formation, culture, and viability assay on a chip.
    Torisawa YS; Takagi A; Nashimoto Y; Yasukawa T; Shiku H; Matsue T
    Biomaterials; 2007 Jan; 28(3):559-66. PubMed ID: 16989897
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Self-adhesive microculture system for extended live cell imaging.
    Skommer J; McGuinness D; Wlodkowic D
    Biotech Histochem; 2011 Jun; 86(3):174-80. PubMed ID: 20109101
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An automatic and quantitative on-chip cell migration assay using self-assembled monolayers combined with real-time cellular impedance sensing.
    Wang L; Zhu J; Deng C; Xing WL; Cheng J
    Lab Chip; 2008 Jun; 8(6):872-8. PubMed ID: 18497905
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Glucagon-like peptide 2 improves intestinal wound healing through induction of epithelial cell migration in vitro-evidence for a TGF--beta-mediated effect.
    Bulut K; Meier JJ; Ansorge N; Felderbauer P; Schmitz F; Hoffmann P; Schmidt WE; Gallwitz B
    Regul Pept; 2004 Sep; 121(1-3):137-43. PubMed ID: 15256284
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Integration of a pump and an electrical sensor into a membrane-based PDMS microbioreactor for cell culture and drug testing.
    Ostrovidov S; Sakai Y; Fujii T
    Biomed Microdevices; 2011 Oct; 13(5):847-64. PubMed ID: 21728068
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Multiple rows of cells behind an epithelial wound edge extend cryptic lamellipodia to collectively drive cell-sheet movement.
    Farooqui R; Fenteany G
    J Cell Sci; 2005 Jan; 118(Pt 1):51-63. PubMed ID: 15585576
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Multi-scale modeling of a wound-healing cell migration assay.
    Cai AQ; Landman KA; Hughes BD
    J Theor Biol; 2007 Apr; 245(3):576-94. PubMed ID: 17188306
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Microfabricated multilayer parylene-C stencils for the generation of patterned dynamic co-cultures.
    Jinno S; Moeller HC; Chen CL; Rajalingam B; Chung BG; Dokmeci MR; Khademhosseini A
    J Biomed Mater Res A; 2008 Jul; 86(1):278-88. PubMed ID: 18442109
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biosensing and monitoring of cell populations using the hydrogel bacterial microchip.
    Fesenko DO; Nasedkina TV; Prokopenko DV; Mirzabekov AD
    Biosens Bioelectron; 2005 Mar; 20(9):1860-5. PubMed ID: 15681206
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A three-dimensional flow control concept for single-cell experiments on a microchip. 1. Cell selection, cell retention, cell culture, cell balancing, and cell scanning.
    Peng XY; Li PC
    Anal Chem; 2004 Sep; 76(18):5273-81. PubMed ID: 15362883
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Toward point-of-care microchip profiling of proteins.
    Osiri JK; Shadpour H
    Bioanalysis; 2010 Oct; 2(10):1745-54. PubMed ID: 21083326
    [TBL] [Abstract][Full Text] [Related]  

  • 15. JNK MAPK signaling contributes in vivo to injury-induced corneal epithelial migration.
    Okada Y; Saika S; Shirai K; Yamanaka O; Kitano A; Wang Z; Yang H; Reinach P
    Ophthalmic Res; 2009; 42(4):185-92. PubMed ID: 19672126
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Micro-well arrays for 3D shape control and high resolution analysis of single cells.
    Ochsner M; Dusseiller MR; Grandin HM; Luna-Morris S; Textor M; Vogel V; Smith ML
    Lab Chip; 2007 Aug; 7(8):1074-7. PubMed ID: 17653351
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Using a co-culture microsystem for cell migration under fluid shear stress.
    Yeh CH; Tsai SH; Wu LW; Lin YC
    Lab Chip; 2011 Aug; 11(15):2583-90. PubMed ID: 21695290
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Intestinal epithelial wound healing assay in an epithelial-mesenchymal co-culture system.
    Seltana A; Basora N; Beaulieu JF
    Wound Repair Regen; 2010; 18(1):114-22. PubMed ID: 20082684
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Cells on chips.
    El-Ali J; Sorger PK; Jensen KF
    Nature; 2006 Jul; 442(7101):403-11. PubMed ID: 16871208
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Traction force microscopy on-chip: shear deformation of fibroblast cells.
    Das T; Maiti TK; Chakraborty S
    Lab Chip; 2008 Aug; 8(8):1308-18. PubMed ID: 18651073
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.