BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 21776782)

  • 1. Measurements of multidetector CT surface dose distributions using a film dosimeter and chest phantom.
    Tominaga M; Kawataa Y; Niki N; Moriyama N; Yamada K; Ueno J; Nishitani H
    Med Phys; 2011 May; 38(5):2467-78. PubMed ID: 21776782
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of surface dose and image quality using the half-scan mode in chest computed tomography-guided interventional radiology: a phantom study.
    Hasegawa H; Sato J; Kobayashi I
    Radiol Phys Technol; 2018 Jun; 11(2):138-148. PubMed ID: 29488072
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dosimetric characterization of a body-conforming radiochromic sheet.
    Wang YF; Dona O; Liu K; Adamovics J; Wuu CS
    J Appl Clin Med Phys; 2020 Mar; 21(3):167-177. PubMed ID: 32100948
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Characterization and implementation of OSL dosimeters for use in evaluating the efficacy of organ-based tube current modulation for CT scans of the face and orbits.
    Marsh RM; Silosky M
    Med Phys; 2015 Apr; 42(4):1730-8. PubMed ID: 25832062
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Utilizing a simple CT dosimetry phantom for the comprehension of the operational characteristics of CT AEC systems.
    Tsalafoutas IA; Varsamidis A; Thalassinou S; Efstathopoulos EP
    Med Phys; 2013 Nov; 40(11):111918. PubMed ID: 24320451
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Performance Evaluation of a Multichannel All-In-One Phantom Dosimeter for Dose Measurement of Diagnostic X-ray Beam.
    Jeon H; Yoo WJ; Shin SH; Kwon G; Kim M; Kim HJ; Song YB; Jang KW; Youn WS; Lee B
    Sensors (Basel); 2015 Nov; 15(11):28490-501. PubMed ID: 26569252
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of an X-Ray Dose Profile Derived from an Optically Stimulated Luminescent Dosimeter during Computed Tomographic Fluoroscopy.
    Hasegawa H; Sato M; Tanaka H
    PLoS One; 2015; 10(7):e0132154. PubMed ID: 26151914
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms.
    DeMarco JJ; Cagnon CH; Cody DD; Stevens DM; McCollough CH; O'Daniel J; McNitt-Gray MF
    Phys Med Biol; 2005 Sep; 50(17):3989-4004. PubMed ID: 16177525
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development and characterization of a three-dimensional radiochromic film stack dosimeter for megavoltage photon beam dosimetry.
    McCaw TJ; Micka JA; DeWerd LA
    Med Phys; 2014 May; 41(5):052104. PubMed ID: 24784393
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Report on the 89th Scientific Assembly and Annual Meeting of the Radiological Society of North America--analysis of radiation dose by a change of a scan parameter of multi-slice computed tomography by a film method].
    Akagi N; Ohkawa Y; Kadohisa S; Nakagiri Y; Hiraki Y
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2004 Dec; 60(12):1664-5. PubMed ID: 15614213
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reference dosimetry during diagnostic CT examination using XR-QA radiochromic film model.
    Boivin J; Tomic N; Fadlallah B; Deblois F; Devic S
    Med Phys; 2011 Sep; 38(9):5119-29. PubMed ID: 21978057
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Application of Gafchromic film in the study of dosimetry methods in CT phantoms.
    Martin CJ; Gentle DJ; Sookpeng S; Loveland J
    J Radiol Prot; 2011 Dec; 31(4):389-409. PubMed ID: 22089894
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dose reduction by automatic exposure control in multidetector computed tomography: comparison between measurement and calculation.
    Lechel U; Becker C; Langenfeld-Jäger G; Brix G
    Eur Radiol; 2009 Apr; 19(4):1027-34. PubMed ID: 18987864
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Radiation dose reduction to the breast in thoracic CT: comparison of bismuth shielding, organ-based tube current modulation, and use of a globally decreased tube current.
    Wang J; Duan X; Christner JA; Leng S; Yu L; McCollough CH
    Med Phys; 2011 Nov; 38(11):6084-92. PubMed ID: 22047373
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Upper limits of the photon fluence rate on CT detectors: Case study on a commercial scanner.
    Persson M; Bujila R; Nowik P; Andersson H; Kull L; Andersson J; Bornefalk H; Danielsson M
    Med Phys; 2016 Jul; 43(7):4398. PubMed ID: 27370155
    [TBL] [Abstract][Full Text] [Related]  

  • 16. 3D automatic exposure control for 64-detector row CT: radiation dose reduction in chest phantom study.
    Matsumoto K; Ohno Y; Koyama H; Kono A; Inokawa H; Onishi Y; Nogami M; Takenaka D; Araki T; Sugimura K
    Eur J Radiol; 2011 Mar; 77(3):522-7. PubMed ID: 19836179
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Novel methods of measuring single scan dose profiles and cumulative dose in CT.
    Nakonechny KD; Fallone BG; Rathee S
    Med Phys; 2005 Jan; 32(1):98-109. PubMed ID: 15719960
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dose reduction during CT fluoroscopy: phantom study of angular beam modulation.
    Hohl C; Suess C; Wildberger JE; Honnef D; Das M; Mühlenbruch G; Schaller A; Günther RW; Mahnken AH
    Radiology; 2008 Feb; 246(2):519-25. PubMed ID: 18227544
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Initial evaluation of commercial optical CT-based 3D gel dosimeter.
    Islam KT; Dempsey JF; Ranade MK; Maryanski MJ; Low DA
    Med Phys; 2003 Aug; 30(8):2159-68. PubMed ID: 12945982
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Technical Note: Phantom study to evaluate the dose and image quality effects of a computed tomography organ-based tube current modulation technique.
    Gandhi D; Crotty DJ; Stevens GM; Schmidt TG
    Med Phys; 2015 Nov; 42(11):6572-8. PubMed ID: 26520748
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.