  • 1. Adverse events due to suspected nickel hypersensitivity in patients with essure micro-inserts.
    Zurawin RK; Zurawin JL
    J Minim Invasive Gynecol; 2011; 18(4):475-82. PubMed ID: 21777837
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of Nickel Allergic Reactions to the Essure Micro Insert: Theoretical Risk or Daily Practice?
    Siemons S; Vleugels M; van Eijndhoven H
    J Minim Invasive Gynecol; 2017 Jan; 24(1):140-144. PubMed ID: 27621196
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Analysis of adverse events with Essure hysteroscopic sterilization reported to the Manufacturer and User Facility Device Experience database.
    Al-Safi ZA; Shavell VI; Hobson DT; Berman JM; Diamond MP
    J Minim Invasive Gynecol; 2013; 20(6):825-9. PubMed ID: 24183273
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Are Adverse Events Attributed to Essure Associated With Nickel Sensitization?
    Raison-Peyron N; Du-Thanh A; Compan C; Perrochia H; Francini S; Duflos C; Crochet P
    Dermatitis; 2020; 31(2):122-127. PubMed ID: 32168143
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Interatrial shunt closure devices in patients with nickel allergy.
    Reddy BT; Patel JB; Powell DL; Michaels AD
    Catheter Cardiovasc Interv; 2009 Oct; 74(4):647-51. PubMed ID: 19777603
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Copper allergy revisited.
    Wöhrl S; Hemmer W; Focke M; Götz M; Jarisch R
    J Am Acad Dermatol; 2001 Dec; 45(6):863-70. PubMed ID: 11712031
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Providing Re-Essure-ance to the Nickel-Allergic Patient Considering Hysteroscopic Sterilization.
    Lane A; Tyson A; Thurston E
    J Minim Invasive Gynecol; 2016 Jan; 23(1):126-9. PubMed ID: 26260300
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Patch Testing for Metal Allergy With Manufacturer-Supplied Materials Before Nuss Bar Insertion.
    Heitmiller K; French A; Alaish SM; Goldner R; Gaspari AA
    Dermatitis; 2015; 26(6):271-5. PubMed ID: 26551606
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Nickel-related hypersensitivity reactions following endovascular interventions: A review of current evidence.
    Tjen VH; Yang PZ
    Sci Prog; 2023; 106(4):368504231200626. PubMed ID: 37872684
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Allergic skin disease: investigation of both immediate- and delayed-type hypersensitivity is essential.
    Usmani N; Wilkinson SM
    Clin Exp Allergy; 2007 Oct; 37(10):1541-6. PubMed ID: 17883733
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Techniques for removal of the Essure hysteroscopic tubal occlusion device.
    Lannon BM; Lee SY
    Fertil Steril; 2007 Aug; 88(2):497.e13-4. PubMed ID: 17397840
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ultrasound: an effective method for localization of the echogenic Essure sterilization micro-insert: correlation with radiologic evaluations.
    Kerin JF; Levy BS
    J Minim Invasive Gynecol; 2005; 12(1):50-4. PubMed ID: 15904599
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Micro analysis of metals in dental restorations as part of a diagnostic approach in metal allergies.
    Muris J; Feilzer AJ
    Neuro Endocrinol Lett; 2006 Dec; 27 Suppl 1():49-52. PubMed ID: 16804513
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Nickel allergy and the amplatzer septal occluder.
    Singh HR; Turner DR; Forbes TJ
    J Invasive Cardiol; 2004 Nov; 16(11):681-2. PubMed ID: 15550748
    [No Abstract]   [Full Text] [Related]  

  • 15. Nickel allergy induced systemic reaction to an intracardiac amplatzer device.
    Prestipino F; Pragliola C; Lusini M; Chello M
    J Card Surg; 2014 May; 29(3):349-50. PubMed ID: 24762035
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical expression of nickel contact dermatitis primed by diagnostic patch test.
    Theler B; Bucher C; French LE; Ballmer Weber B; Hofbauer GF
    Dermatology; 2009; 219(1):73-6. PubMed ID: 19349696
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hypersensitivity reactions to metallic implants - diagnostic algorithm and suggested patch test series for clinical use.
    Schalock PC; Menné T; Johansen JD; Taylor JS; Maibach HI; Lidén C; Bruze M; Thyssen JP
    Contact Dermatitis; 2012 Jan; 66(1):4-19. PubMed ID: 21957996
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Validity of MELISA for metal sensitivity testing.
    Valentine-Thon E; Schiwara HW
    Neuro Endocrinol Lett; 2003; 24(1-2):57-64. PubMed ID: 12743534
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Adverse patient reactions during orthodontic treatment with fixed appliances.
    Kerosuo HM; Dahl JE
    Am J Orthod Dentofacial Orthop; 2007 Dec; 132(6):789-95. PubMed ID: 18068598
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Delayed systemic allergic dermatitis following Essure insert: A case report.
    Baltus T; Brown J; Mahmoud I
    Case Rep Womens Health; 2018 Oct; 20():e00075. PubMed ID: 30225200
    [TBL] [Abstract][Full Text] [Related]  