These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

298 related articles for article (PubMed ID: 21777888)

  • 1. Angiographic geometric changes of the lumen arterial wall after bioresorbable vascular scaffolds and metallic platform stents at 1-year follow-up.
    Gomez-Lara J; Brugaletta S; Farooq V; van Geuns RJ; De Bruyne B; Windecker S; McClean D; Thuesen L; Dudek D; Koolen J; Whitbourn R; Smits PC; Chevalier B; Morel MA; Dorange C; Veldhof S; Rapoza R; Garcia-Garcia HM; Ormiston JA; Serruys PW
    JACC Cardiovasc Interv; 2011 Jul; 4(7):789-99. PubMed ID: 21777888
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A comparison of the conformability of everolimus-eluting bioresorbable vascular scaffolds to metal platform coronary stents.
    Gomez-Lara J; Garcia-Garcia HM; Onuma Y; Garg S; Regar E; De Bruyne B; Windecker S; McClean D; Thuesen L; Dudek D; Koolen J; Whitbourn R; Smits PC; Chevalier B; Dorange C; Veldhof S; Morel MA; de Vries T; Ormiston JA; Serruys PW
    JACC Cardiovasc Interv; 2010 Nov; 3(11):1190-8. PubMed ID: 21087756
    [TBL] [Abstract][Full Text] [Related]  

  • 3. 1-year clinical outcomes of diabetic patients treated with everolimus-eluting bioresorbable vascular scaffolds: a pooled analysis of the ABSORB and the SPIRIT trials.
    Muramatsu T; Onuma Y; van Geuns RJ; Chevalier B; Patel TM; Seth A; Diletti R; García-García HM; Dorange CC; Veldhof S; Cheong WF; Ozaki Y; Whitbourn R; Bartorelli A; Stone GW; Abizaid A; Serruys PW; ; ; ; ; ;
    JACC Cardiovasc Interv; 2014 May; 7(5):482-93. PubMed ID: 24746650
    [TBL] [Abstract][Full Text] [Related]  

  • 4. ABSORB II randomized controlled trial: a clinical evaluation to compare the safety, efficacy, and performance of the Absorb everolimus-eluting bioresorbable vascular scaffold system against the XIENCE everolimus-eluting coronary stent system in the treatment of subjects with ischemic heart disease caused by de novo native coronary artery lesions: rationale and study design.
    Diletti R; Serruys PW; Farooq V; Sudhir K; Dorange C; Miquel-Hebert K; Veldhof S; Rapoza R; Onuma Y; Garcia-Garcia HM; Chevalier B
    Am Heart J; 2012 Nov; 164(5):654-63. PubMed ID: 23137495
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Incidence and short-term clinical outcomes of small side branch occlusion after implantation of an everolimus-eluting bioresorbable vascular scaffold: an interim report of 435 patients in the ABSORB-EXTEND single-arm trial in comparison with an everolimus-eluting metallic stent in the SPIRIT first and II trials.
    Muramatsu T; Onuma Y; García-García HM; Farooq V; Bourantas CV; Morel MA; Li X; Veldhof S; Bartorelli A; Whitbourn R; Abizaid A; Serruys PW;
    JACC Cardiovasc Interv; 2013 Mar; 6(3):247-57. PubMed ID: 23517836
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Incidence and imaging outcomes of acute scaffold disruption and late structural discontinuity after implantation of the absorb Everolimus-Eluting fully bioresorbable vascular scaffold: optical coherence tomography assessment in the ABSORB cohort B Trial (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions).
    Onuma Y; Serruys PW; Muramatsu T; Nakatani S; van Geuns RJ; de Bruyne B; Dudek D; Christiansen E; Smits PC; Chevalier B; McClean D; Koolen J; Windecker S; Whitbourn R; Meredith I; Garcia-Garcia HM; Veldhof S; Rapoza R; Ormiston JA
    JACC Cardiovasc Interv; 2014 Dec; 7(12):1400-11. PubMed ID: 25523532
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of in vivo acute stent recoil between the bioresorbable everolimus-eluting coronary scaffolds (revision 1.0 and 1.1) and the metallic everolimus-eluting stent.
    Onuma Y; Serruys PW; Gomez J; de Bruyne B; Dudek D; Thuesen L; Smits P; Chevalier B; McClean D; Koolen J; Windecker S; Whitbourn R; Meredith I; Garcia-Garcia H; Ormiston JA;
    Catheter Cardiovasc Interv; 2011 Jul; 78(1):3-12. PubMed ID: 21413120
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Head-to-head comparison of the neointimal response between metallic and bioresorbable everolimus-eluting scaffolds using optical coherence tomography.
    Gomez-Lara J; Brugaletta S; Farooq V; Onuma Y; Diletti R; Windecker S; Thuesen L; McClean D; Koolen J; Whitbourn R; Dudek D; Smits PC; Chevalier B; Regar E; Veldhof S; Rapoza R; Ormiston JA; Garcia-Garcia HM; Serruys PW
    JACC Cardiovasc Interv; 2011 Dec; 4(12):1271-80. PubMed ID: 22192368
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of lesion length and vessel size on clinical outcomes after percutaneous coronary intervention with everolimus- versus paclitaxel-eluting stents pooled analysis from the SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice) Randomized Trials.
    Claessen BE; Smits PC; Kereiakes DJ; Parise H; Fahy M; Kedhi E; Serruys PW; Lansky AJ; Cristea E; Sudhir K; Sood P; Simonton CA; Stone GW
    JACC Cardiovasc Interv; 2011 Nov; 4(11):1209-15. PubMed ID: 22115661
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of the second generation of a bioresorbable everolimus-eluting vascular scaffold for the treatment of de novo coronary artery stenosis: 12-month clinical and imaging outcomes.
    Serruys PW; Onuma Y; Dudek D; Smits PC; Koolen J; Chevalier B; de Bruyne B; Thuesen L; McClean D; van Geuns RJ; Windecker S; Whitbourn R; Meredith I; Dorange C; Veldhof S; Hebert KM; Sudhir K; Garcia-Garcia HM; Ormiston JA
    J Am Coll Cardiol; 2011 Oct; 58(15):1578-88. PubMed ID: 21958884
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Bioresorbable Vascular Scaffolds Versus Metallic Stents in Patients With Coronary Artery Disease: ABSORB China Trial.
    Gao R; Yang Y; Han Y; Huo Y; Chen J; Yu B; Su X; Li L; Kuo HC; Ying SW; Cheong WF; Zhang Y; Su X; Xu B; Popma JJ; Stone GW;
    J Am Coll Cardiol; 2015 Dec; 66(21):2298-2309. PubMed ID: 26471805
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Conformability in everolimus-eluting bioresorbable scaffolds compared with metal platform coronary stents in long lesions.
    Fam JM; Ishibashi Y; Felix C; Zhang BC; Diletti R; van Mieghem N; Regar E; van Domburg R; Onuma Y; van Geuns RJ
    Int J Cardiovasc Imaging; 2017 Dec; 33(12):1863-1871. PubMed ID: 28685314
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of the second generation of a bioresorbable everolimus drug-eluting vascular scaffold for treatment of de novo coronary artery stenosis: six-month clinical and imaging outcomes.
    Serruys PW; Onuma Y; Ormiston JA; de Bruyne B; Regar E; Dudek D; Thuesen L; Smits PC; Chevalier B; McClean D; Koolen J; Windecker S; Whitbourn R; Meredith I; Dorange C; Veldhof S; Miquel-Hebert K; Rapoza R; García-García HM
    Circulation; 2010 Nov; 122(22):2301-12. PubMed ID: 21098436
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Clinical follow-up 3 years after everolimus- and paclitaxel-eluting stents: a pooled analysis from the SPIRIT II (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions) and SPIRIT III (A Clinical Evaluation of the Investigational Device XIENCE V Everolimus Eluting Coronary Stent System [EECSS] in the Treatment of Subjects With De Novo Native Coronary Artery Lesions) randomized trials.
    Caixeta A; Lansky AJ; Serruys PW; Hermiller JB; Ruygrok P; Onuma Y; Gordon P; Yaqub M; Miquel-Hebert K; Veldhof S; Sood P; Su X; Jonnavithula L; Sudhir K; Stone GW;
    JACC Cardiovasc Interv; 2010 Dec; 3(12):1220-8. PubMed ID: 21232715
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Risk of target lesion failure in relationship to vessel angiographic geometry and stent conformability using the second generation of drug-eluting stents.
    Gomez-Lara J; Heo JH; Brugaletta S; Garg S; Garcia-Garcia HM; van Geuns RJ; Silber S; Windecker S; Serruys PW
    Am Heart J; 2011 Dec; 162(6):1069-1079.e2. PubMed ID: 22137081
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of everolimus-eluting and paclitaxel-eluting coronary stents in patients undergoing multilesion and multivessel intervention: the SPIRIT III (A Clinical Evaluation of the Investigational Device XIENCE V Everolimus Eluting Coronary Stent System [EECSS] in the Treatment of Subjects With De Novo Native Coronary Artery Lesions) and SPIRIT IV (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Subjects With De Novo Native Coronary Artery Lesions) randomized trials.
    Kereiakes DJ; Sudhir K; Hermiller JB; Gordon PC; Ferguson J; Yaqub M; Sood P; Su X; Yakubov S; Lansky AJ; Stone GW
    JACC Cardiovasc Interv; 2010 Dec; 3(12):1229-39. PubMed ID: 21232716
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intraindividual Comparison of Everolimus-Eluting Bioresorbable Vascular Scaffolds Versus Drug-Eluting Metallic Stents.
    Cassese S; Hoppmann P; Kufner S; Byrne RA; Wiebe J; Colleran R; Giacoppo D; Harada Y; Laugwitz KL; Schunkert H; Fusaro M; Kastrati A
    Circ Cardiovasc Interv; 2016 Aug; 9(8):. PubMed ID: 27512088
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of acute gain and late lumen loss after PCI with bioresorbable vascular scaffolds versus everolimus-eluting stents: an exploratory observational study prior to a randomised trial.
    Zhang YJ; Bourantas CV; Muramatsu T; Iqbal J; Farooq V; Diletti R; Campos CA; Onuma Y; Garcia-Garcia HM; Serruys PW
    EuroIntervention; 2014 Oct; 10(6):672-80. PubMed ID: 24472767
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of a fully bioresorbable vascular scaffold in patients with coronary artery disease: design of and rationale for the ABSORB III randomized trial.
    Kereiakes DJ; Ellis SG; Popma JJ; Fitzgerald PJ; Samady H; Jones-McMeans J; Zhang Z; Cheong WF; Su X; Ben-Yehuda O; Stone GW
    Am Heart J; 2015 Oct; 170(4):641-651.e3. PubMed ID: 26386787
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Clinical and intravascular imaging outcomes at 1 and 2 years after implantation of absorb everolimus eluting bioresorbable vascular scaffolds in small vessels. Late lumen enlargement: does bioresorption matter with small vessel size? Insight from the ABSORB cohort B trial.
    Diletti R; Farooq V; Girasis C; Bourantas C; Onuma Y; Heo JH; Gogas BD; van Geuns RJ; Regar E; de Bruyne B; Dudek D; Thuesen L; Chevalier B; McClean D; Windecker S; Whitbourn RJ; Smits P; Koolen J; Meredith I; Li X; Miquel-Hebert K; Veldhof S; Garcia-Garcia HM; Ormiston JA; Serruys PW
    Heart; 2013 Jan; 99(2):98-105. PubMed ID: 23118346
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.