151 related articles for article (PubMed ID: 21778299)
1. Effect of order of draw of blood samples during phlebotomy on routine biochemistry results.
Sulaiman RA; Cornes MP; Whitehead SJ; Othonos N; Ford C; Gama R
J Clin Pathol; 2011 Nov; 64(11):1019-20. PubMed ID: 21778299
[TBL] [Abstract][Full Text] [Related]
2. Spurious hyperkalaemia due to EDTA contamination: common and not always easy to identify.
Cornes MP; Ford C; Gama R
Ann Clin Biochem; 2008 Nov; 45(Pt 6):601-3. PubMed ID: 18768536
[TBL] [Abstract][Full Text] [Related]
3. Incorrect order of draw of blood samples does not cause potassium EDTA sample contamination.
Cornes MR; Sulaiman RA; Whitehead SJ; Othonos N; Ford C; Gama R
Br J Biomed Sci; 2012; 69(3):136-8. PubMed ID: 23057163
[No Abstract] [Full Text] [Related]
4. kEDTA Sample Contamination: A Reappraisal.
Chadwick K; Whitehead SJ; Ford C; Gama R
J Appl Lab Med; 2019 May; 3(6):925-935. PubMed ID: 31639684
[TBL] [Abstract][Full Text] [Related]
5. Order of draw of blood samples affect potassium results without K-EDTA contamination during routine workflow.
Ercan Ş; Ramadan B; Gerenli O
Biochem Med (Zagreb); 2021 Jun; 31(2):020704. PubMed ID: 33927554
[TBL] [Abstract][Full Text] [Related]
6. The order of draw: myth or science?
Salvagno G; Lima-Oliveira G; Brocco G; Danese E; Guidi GC; Lippi G
Clin Chem Lab Med; 2013 Dec; 51(12):2281-5. PubMed ID: 23846149
[TBL] [Abstract][Full Text] [Related]
7. Combined false hyperkalemia and hypocalcemia due to specimen contamination during routine phlebotomy.
Naguib MT; Evans N
South Med J; 2002 Oct; 95(10):1218-20. PubMed ID: 12425515
[TBL] [Abstract][Full Text] [Related]
8. Effects of contamination of blood specimens with liquid potassium-EDTA anticoagulant.
Davidson DF
Ann Clin Biochem; 2002 May; 39(Pt 3):273-80. PubMed ID: 12038602
[TBL] [Abstract][Full Text] [Related]
9. EDTA contamination of serum samples: common but not necessarily significant.
Hawkins RC
Ann Clin Biochem; 2011 Sep; 48(Pt 5):478. PubMed ID: 21719510
[No Abstract] [Full Text] [Related]
10. Effect of automated feedback laboratory comments promoting good phlebotomy practice on the frequency of ethylenediaminetetraacetic acid (EDTA) contamination of serum samples.
Kalaria T; Ford C; Gama R
Ann Clin Biochem; 2023 Jan; 60(1):63-67. PubMed ID: 36200920
[TBL] [Abstract][Full Text] [Related]
11. Relevance of EDTA carryover during blood collection.
Cadamuro J; Felder TK; Oberkofler H; Mrazek C; Wiedemann H; Haschke-Becher E
Clin Chem Lab Med; 2015 Jul; 53(8):1271-8. PubMed ID: 25720083
[TBL] [Abstract][Full Text] [Related]
12. Managing ethylenediaminetetraacetic acid (EDTA) interference in EDTA contaminated samples - selectivity in reporting analytes.
Kalaria T; Ford C; Gama R
Ann Clin Biochem; 2023 Mar; 60(2):92-99. PubMed ID: 36348502
[TBL] [Abstract][Full Text] [Related]
13. Influence of separator gel in Sarstedt S-Monovette® serum tubes on various therapeutic drugs, hormones, and proteins.
Schouwers S; Brandt I; Willemse J; Van Regenmortel N; Uyttenbroeck W; Wauters A; Neels H
Clin Chim Acta; 2012 Jan; 413(1-2):100-4. PubMed ID: 21945632
[TBL] [Abstract][Full Text] [Related]
14. Multi-centre observational study of spurious hyperkalaemia due to EDTA contamination.
Cornes MP; Davidson F; Darwin L; Gay C; Redpath M; Waldron JL; Ford C; Gama R
Clin Lab; 2010; 56(11-12):597-9. PubMed ID: 21141447
[TBL] [Abstract][Full Text] [Related]
15. Serum ethylenediaminetetraacetic acid concentrations in routine samples submitted for biochemical analysis.
White G
Ann Clin Biochem; 2010 Sep; 47(Pt 5):485-6. PubMed ID: 20595407
[TBL] [Abstract][Full Text] [Related]
16. Preanalytical potassium EDTA sample contamination: open versus closed phlebotomy systems.
Asif U; Whitehead SJ; Ford C; Gama R
Ann Clin Biochem; 2019 Nov; 56(6):711-714. PubMed ID: 31500437
[No Abstract] [Full Text] [Related]
17. [Concentration of various bioelements in the serum of otosclerosis patients].
Martini A; Vespasiani F
Ann Otolaryngol Chir Cervicofac; 1985; 102(1):69-71. PubMed ID: 4004018
[TBL] [Abstract][Full Text] [Related]
18. Order of draw practices in venous blood sampling at clinical biochemistry departments in the Danish health care system.
Jacobsen KK; Brandt I; Christensen AV; Rimsø BA; Krøier CJ; Sørensen M; Smith J; Jensen KOF; Larsen JM
Clin Biochem; 2018 Jun; 56():113-116. PubMed ID: 29684368
[TBL] [Abstract][Full Text] [Related]
19. Effects of vigorous mixing of blood vacuum tubes on laboratory test results.
Lima-Oliveira G; Lippi G; Salvagno GL; Montagnana M; Gelati M; Volanski W; Boritiza KC; Picheth G; Guidi GC
Clin Biochem; 2013 Feb; 46(3):250-4. PubMed ID: 23146916
[TBL] [Abstract][Full Text] [Related]
20. Should we measure serum or plasma lead concentrations?
Rezende VB; Amaral JH; Gerlach RF; Barbosa F; Tanus-Santos JE
J Trace Elem Med Biol; 2010 Jul; 24(3):147-51. PubMed ID: 20569924
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]