204 related articles for article (PubMed ID: 21780056)
21. Three-dimensional gadolinium-enhanced magnetic resonance angiography used as a "one-stop shop'' imaging procedure for venous thromboembolism: a pilot study.
Obernosterer A; Aschauer M; Portugaller H; Köppel H; Lipp RW
Angiology; 2005; 56(4):423-30. PubMed ID: 16079927
[TBL] [Abstract][Full Text] [Related]
22. Comparison of gadofosveset-enhanced three-dimensional magnetic resonance angiography with digital subtraction angiography for lower-extremity peripheral arterial occlusive disease.
Grijalba FU; Esandi MC
Acta Radiol; 2010 Apr; 51(3):284-9. PubMed ID: 20105092
[TBL] [Abstract][Full Text] [Related]
23. [MR venography in deep venous thromboses of the leg and pelvis. A comparison of 2D single layer images and 3D MIP reconstructions with phlebography].
Siewert B; Kaiser WA; Layer G; Träber F; Kania U; Hartlapp J
Rofo; 1992 Jun; 156(6):549-54. PubMed ID: 1617174
[TBL] [Abstract][Full Text] [Related]
24. [Real-time sonography in deep thrombosis of the pelvic and leg veins. A prospective comparison to phlebography].
Herzog P; Anastasiu M; Wollbrink W; Herrmann W; Holtermüller KH
Med Klin (Munich); 1991 Mar; 86(3):132-7. PubMed ID: 2034176
[TBL] [Abstract][Full Text] [Related]
25. Black-blood thrombus imaging (BTI): a contrast-free cardiovascular magnetic resonance approach for the diagnosis of non-acute deep vein thrombosis.
Xie G; Chen H; He X; Liang J; Deng W; He Z; Ye Y; Yang Q; Bi X; Liu X; Li D; Fan Z
J Cardiovasc Magn Reson; 2017 Jan; 19(1):4. PubMed ID: 28095878
[TBL] [Abstract][Full Text] [Related]
26. Detecting iliac vein thrombosis with current protocols of lower extremity venous duplex ultrasound.
Jain AK; Soult MC; Resnick SA; Desai K; Astleford P; Eskandari MK; Rodriguez HE
J Vasc Surg Venous Lymphat Disord; 2018 Nov; 6(6):724-729. PubMed ID: 30336900
[TBL] [Abstract][Full Text] [Related]
27. Retrospective assessment of the utility of an iron-based agent for contrast-enhanced magnetic resonance venography in patients with endstage renal diseases.
Bashir MR; Mody R; Neville A; Javan R; Seaman D; Kim CY; Gupta RT; Jaffe TA
J Magn Reson Imaging; 2014 Jul; 40(1):113-8. PubMed ID: 24130008
[TBL] [Abstract][Full Text] [Related]
28. [Acute thrombosis of pelvic and leg veins in agenesis of the renal segment of the inferior vena cava].
Körber T; Petzsch M; Placke J; Ismer B; Schulze C
Z Kardiol; 2001 Jan; 90(1):52-7. PubMed ID: 11220087
[TBL] [Abstract][Full Text] [Related]
29. High-resolution three‑dimensional contrast‑enhanced magnetic resonance venography in children: comparison of gadofosveset trisodium with ferumoxytol.
Shahrouki P; Khan SN; Yoshida T; Iskander PJ; Ghahremani S; Finn JP
Pediatr Radiol; 2022 Mar; 52(3):501-512. PubMed ID: 34936018
[TBL] [Abstract][Full Text] [Related]
30. Comprehensive MRA of the lower limbs including high-resolution extended-phase infra-inguinal imaging with gadobenate dimeglumine: initial experience with inter-individual comparison to the blood-pool contrast agent gadofosveset trisodium.
Christie A; Chandramohan S; Roditi G
Clin Radiol; 2013 Feb; 68(2):125-30. PubMed ID: 22884130
[TBL] [Abstract][Full Text] [Related]
31. Deep-vein thrombosis in high-energy skeletal trauma despite thromboprophylaxis.
Stannard JP; Singhania AK; Lopez-Ben RR; Anderson ER; Farris RC; Volgas DA; McGwin GR; Alonso JE
J Bone Joint Surg Br; 2005 Jul; 87(7):965-8. PubMed ID: 15972912
[TBL] [Abstract][Full Text] [Related]
32. MR venography with true fast imaging with steady-state precession for suspected lower-limb deep vein thrombosis.
Cantwell CP; Cradock A; Bruzzi J; Fitzpatrick P; Eustace S; Murray JG
J Vasc Interv Radiol; 2006 Nov; 17(11 Pt 1):1763-9. PubMed ID: 17142706
[TBL] [Abstract][Full Text] [Related]
33. Deep vein thrombosis using noncontrast-enhanced MR venography with electrocardiographically gated three-dimensional half-Fourier FSE: preliminary experience.
Ono A; Murase K; Taniguchi T; Shibutani O; Takata S; Kobashi Y; Miyazaki M
Magn Reson Med; 2009 Apr; 61(4):907-17. PubMed ID: 19195017
[TBL] [Abstract][Full Text] [Related]
34. Unenhanced flow-independent MR venography by using signal targeting alternative radiofrequency and flow-independent relaxation enhancement.
Edelman RR; Koktzoglou I
Radiology; 2009 Jan; 250(1):236-45. PubMed ID: 19092096
[TBL] [Abstract][Full Text] [Related]
35. A novel scoring system for lower-extremity venous pathology analysed using magnetic resonance venography and duplex ultrasound.
Arnoldussen CW; Toonder I; Wittens CH
Phlebology; 2012 Mar; 27 Suppl 1():163-70. PubMed ID: 22312085
[TBL] [Abstract][Full Text] [Related]
36. Contrast-enhanced US in the assessment of the ilio-caval axis in deep venous thrombosis.
Ricci P; Intrieri F; Cantisani V; Drudi FM; Fasoli F; Arduini F; Pagliara E; Benedetti Valentini F; Passariello R
Radiol Med; 2004; 107(5-6):506-14. PubMed ID: 15195013
[TBL] [Abstract][Full Text] [Related]
37. Gadofosveset-enhanced MR imaging for the preoperative evaluation of potential living kidney donors: correlation with intraoperative findings.
Kuhlemann J; Blondin D; Grotemeyer D; Zgoura P; Reichelt D; Heinen W; Scherer A; Lanzman RS
Rofo; 2010 Nov; 182(11):1001-9. PubMed ID: 20922646
[TBL] [Abstract][Full Text] [Related]
38. MR venography using an intravascular contrast agent: results from a multicenter phase 2 study of dosage.
Larsson EM; Sundén P; Olsson CG; Debatin J; Duerinckx AJ; Baum R; Hahn D; Ebner F
AJR Am J Roentgenol; 2003 Jan; 180(1):227-32. PubMed ID: 12490510
[TBL] [Abstract][Full Text] [Related]
39. Aortoiliac occlusive disease in patients with known or suspected peripheral vascular disease: safety and efficacy of gadofosveset-enhanced MR angiography--multicenter comparative phase III study.
Rapp JH; Wolff SD; Quinn SF; Soto JA; Meranze SG; Muluk S; Blebea J; Johnson SP; Rofsky NM; Duerinckx A; Foster GS; Kent KC; Moneta G; Middlebrook MR; Narra VR; Toombs BD; Pollak J; Yucel EK; Shamsi K; Weisskoff RM
Radiology; 2005 Jul; 236(1):71-8. PubMed ID: 15987963
[TBL] [Abstract][Full Text] [Related]
40. Deep venous thrombosis: diagnostic value of non-contrast-enhanced MR venography using electrocardiography-triggered three-dimensional half-Fourier FSE.
Ono A; Murase K; Taniguchi T; Shibutani O; Takata S; Kobashi Y; Hashiguchi Y; Miyazaki M
Magn Reson Med; 2010 Jul; 64(1):88-97. PubMed ID: 20572137
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]