354 related articles for article (PubMed ID: 21783122)
1. The role of heat treatment on microstructure and mechanical properties of Ti-13Zr-13Nb alloy for biomedical load bearing applications.
Majumdar P; Singh SB; Chakraborty M
J Mech Behav Biomed Mater; 2011 Oct; 4(7):1132-44. PubMed ID: 21783122
[TBL] [Abstract][Full Text] [Related]
2. Effects of heat treatment on evolution of microstructure of boron free and boron containing biomedical Ti-13Zr-13Nb alloys.
Majumdar P
Micron; 2012 Aug; 43(8):876-86. PubMed ID: 22459252
[TBL] [Abstract][Full Text] [Related]
3. Influence of in situ TiB reinforcements and role of heat treatment on mechanical properties and biocompatibility of β Ti-alloys.
Majumdar P; Singh SB; Dhara S; Chakraborty M
J Mech Behav Biomed Mater; 2012 Jun; 10():1-12. PubMed ID: 22520414
[TBL] [Abstract][Full Text] [Related]
4. Improved pre-osteoblast response and mechanical compatibility of ultrafine-grained Ti-13Nb-13Zr alloy.
Park CH; Lee CS; Kim YJ; Jang JH; Suh JY; Park JW
Clin Oral Implants Res; 2011 Jul; 22(7):735-742. PubMed ID: 21121961
[TBL] [Abstract][Full Text] [Related]
5. Development of a low elastic modulus and antibacterial Ti-13Nb-13Zr-5Cu titanium alloy by microstructure controlling.
Shi A; Cai D; Hu J; Zhao X; Qin G; Han Y; Zhang E
Mater Sci Eng C Mater Biol Appl; 2021 Jul; 126():112116. PubMed ID: 34082933
[TBL] [Abstract][Full Text] [Related]
6. Corrosion behaviour of heat treated boron free and boron containing Ti-13Zr-13Nb (wt%) alloy in simulated body fluid.
Majumdar P; Singh SB; Chatterjee UK; Chakraborty M
J Mater Sci Mater Med; 2011 Apr; 22(4):797-807. PubMed ID: 21442191
[TBL] [Abstract][Full Text] [Related]
7. Precipitation hardening and microstructure evolution of the Ti-7Nb-10Mo alloy during aging.
Yi R; Liu H; Yi D; Wan W; Wang B; Jiang Y; Yang Q; Wang D; Gao Q; Xu Y; Tang Q
Mater Sci Eng C Mater Biol Appl; 2016 Jun; 63():577-86. PubMed ID: 27040253
[TBL] [Abstract][Full Text] [Related]
8. Nanostructured Ti-13Nb-13Zr alloy for implant application-material scientific, technological, and biological aspects.
Klinge L; Kluy L; Spiegel C; Siemers C; Groche P; Coraça-Huber D
Front Bioeng Biotechnol; 2023; 11():1255947. PubMed ID: 37691899
[TBL] [Abstract][Full Text] [Related]
9. Influence of thermomechanical processing on biomechanical compatibility and electrochemical behavior of new near beta alloy, Ti-20.6Nb-13.6Zr-0.5V.
Mohammed MT; Khan ZA; Manivasagam G; Siddiquee AN
Int J Nanomedicine; 2015; 10 Suppl 1(Suppl 1):223-35. PubMed ID: 26491324
[TBL] [Abstract][Full Text] [Related]
10. Development of a new β Ti alloy with low modulus and favorable plasticity for implant material.
Liang SX; Feng XJ; Yin LX; Liu XY; Ma MZ; Liu RP
Mater Sci Eng C Mater Biol Appl; 2016 Apr; 61():338-43. PubMed ID: 26838858
[TBL] [Abstract][Full Text] [Related]
11. Effects of thermomechanical process on the microstructure and mechanical properties of a fully martensitic titanium-based biomedical alloy.
Elmay W; Prima F; Gloriant T; Bolle B; Zhong Y; Patoor E; Laheurte P
J Mech Behav Biomed Mater; 2013 Feb; 18():47-56. PubMed ID: 23246554
[TBL] [Abstract][Full Text] [Related]
12. Microstructure and mechanical properties of Ti-Zr-Cr biomedical alloys.
Wang P; Feng Y; Liu F; Wu L; Guan S
Mater Sci Eng C Mater Biol Appl; 2015 Jun; 51():148-52. PubMed ID: 25842119
[TBL] [Abstract][Full Text] [Related]
13. Microstructure evolution, mechanical properties, and enhanced bioactivity of Ti-13Nb-13Zr based calcium pyrophosphate composites for biomedical applications.
Hu H; Zhang L; He Z; Jiang Y; Tan J
Mater Sci Eng C Mater Biol Appl; 2019 May; 98():279-287. PubMed ID: 30813028
[TBL] [Abstract][Full Text] [Related]
14. Maximisation of the ratio of microhardness to the Young's modulus of Ti-12Mo-13Nb alloy through microstructure changes.
Gabriel SB; de Almeida LH; Nunes CA; Dille J; Soares GA
Mater Sci Eng C Mater Biol Appl; 2013 Aug; 33(6):3319-24. PubMed ID: 23706216
[TBL] [Abstract][Full Text] [Related]
15. Microstructure, elastic deformation behavior and mechanical properties of biomedical β-type titanium alloy thin-tube used for stents.
Tian Y; Yu Z; Ong CY; Kent D; Wang G
J Mech Behav Biomed Mater; 2015 May; 45():132-41. PubMed ID: 25706668
[TBL] [Abstract][Full Text] [Related]
16. Mechanical response and microstructural evolution of Ti-13Zr-13Nb biomedical alloy under high strain rate load.
Chen TH; Lin SY
Technol Health Care; 2015; 24 Suppl 1():S171-7. PubMed ID: 26409553
[TBL] [Abstract][Full Text] [Related]
17. Ti-Mo alloys employed as biomaterials: effects of composition and aging heat treatment on microstructure and mechanical behavior.
Cardoso FF; Ferrandini PL; Lopes ESN; Cremasco A; Caram R
J Mech Behav Biomed Mater; 2014 Apr; 32():31-38. PubMed ID: 24394773
[TBL] [Abstract][Full Text] [Related]
18. New surface-hardened, low-modulus, corrosion-resistant Ti-13Nb-13Zr alloy for total hip arthroplasty.
Davidson JA; Mishra AK; Kovacs P; Poggie RA
Biomed Mater Eng; 1994; 4(3):231-43. PubMed ID: 7950871
[TBL] [Abstract][Full Text] [Related]
19. Influence of Si addition on the microstructure and mechanical properties of Ti-35Nb alloy for applications in orthopedic implants.
Tavares AM; Ramos WS; de Blas JC; Lopes ES; Caram R; Batista WW; Souza SA
J Mech Behav Biomed Mater; 2015 Nov; 51():74-87. PubMed ID: 26218870
[TBL] [Abstract][Full Text] [Related]
20. Tribological and corrosion behaviors of warm-and hot-rolled Ti-13Nb-13Zr alloys in simulated body fluid conditions.
Lee T; Mathew E; Rajaraman S; Manivasagam G; Singh AK; Lee CS
Int J Nanomedicine; 2015; 10 Suppl 1(Suppl 1):207-12. PubMed ID: 26491322
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]