86 related articles for article (PubMed ID: 21784646)
1. Retrieval analysis of modular total knee replacements: factors influencing backside surface damage.
Brandt JM; MacDonald SJ; Bourne RB; Medley JB
Knee; 2012 Aug; 19(4):306-15. PubMed ID: 21784646
[TBL] [Abstract][Full Text] [Related]
2. Second-generation locking mechanisms and ethylene oxide sterilization reduce tibial insert backside damage in total knee arthroplasty.
Azzam MG; Roy ME; Whiteside LA
J Arthroplasty; 2011 Jun; 26(4):523-30. PubMed ID: 20541356
[TBL] [Abstract][Full Text] [Related]
3. Backside damage corresponding to articular damage in retrieved tibial polyethylene inserts.
Harman MK; Banks SA; Hodge WA
Clin Orthop Relat Res; 2007 May; 458():137-44. PubMed ID: 17242615
[TBL] [Abstract][Full Text] [Related]
4. Current Total Knee Designs: Does Baseplate Roughness or Locking Mechanism Design Affect Polyethylene Backside Wear?
Sisko ZW; Teeter MG; Lanting BA; Howard JL; McCalden RW; Naudie DD; MacDonald SJ; Vasarhelyi EM
Clin Orthop Relat Res; 2017 Dec; 475(12):2970-2980. PubMed ID: 28905208
[TBL] [Abstract][Full Text] [Related]
5. Polished trays reduce backside wear independent of post location in posterior-stabilized TKAs.
Abdel MP; Gesell MW; Hoedt CW; Meyers KN; Wright TM; Haas SB
Clin Orthop Relat Res; 2014 Aug; 472(8):2477-82. PubMed ID: 24733449
[TBL] [Abstract][Full Text] [Related]
6. Post damage in contemporary posterior-stabilized tibial inserts: influence of implant design and clinical relevance.
; Medel FJ; Kurtz SM; Sharkey PF; Austin MS; Klein GR; Cohen AR; Patel H; Goldberg VM; Kraay MJ; Rimnac CM
J Arthroplasty; 2011 Jun; 26(4):606-14. PubMed ID: 21575793
[TBL] [Abstract][Full Text] [Related]
7. Peripheral snap-fit locking mechanisms and smooth surface finish of tibial trays reduce backside wear in fixed-bearing total knee arthroplasty.
Łapaj Ł; Mróz A; Kokoszka P; Markuszewski J; Wendland J; Helak-Łapaj C; Kruczyński J
Acta Orthop; 2017 Feb; 88(1):62-69. PubMed ID: 27781667
[TBL] [Abstract][Full Text] [Related]
8. Backside wear of polyethylene tibial inserts: mechanism and magnitude of material loss.
Conditt MA; Thompson MT; Usrey MM; Ismaily SK; Noble PC
J Bone Joint Surg Am; 2005 Feb; 87(2):326-31. PubMed ID: 15687155
[TBL] [Abstract][Full Text] [Related]
9. Tibial interface wear in retrieved total knee components and correlations with modular insert motion.
Rao AR; Engh GA; Collier MB; Lounici S
J Bone Joint Surg Am; 2002 Oct; 84(10):1849-55. PubMed ID: 12377918
[TBL] [Abstract][Full Text] [Related]
10. Assessment of backside wear from the analysis of 55 retrieved tibial inserts.
Li S; Scuderi G; Furman BD; Bhattacharyya S; Schmieg JJ; Insall JN
Clin Orthop Relat Res; 2002 Nov; (404):75-82. PubMed ID: 12439241
[TBL] [Abstract][Full Text] [Related]
11. Polyethylene damage on the nonarticular surface of modular total knee prostheses.
Cuckler JM; Lemons J; Tamarapalli JR; Beck P
Clin Orthop Relat Res; 2003 May; (410):248-53. PubMed ID: 12771836
[TBL] [Abstract][Full Text] [Related]
12. Tibial tray debonding from the cement mantle is associated with deformation of the backside of polyethylene tibial inserts.
Bhalekar RM; Nargol ME; Shyam N; Nargol AVF; Wells SR; Collier R; Pabbruwe M; Joyce TJ; Langton DJ
Bone Joint J; 2021 Dec; 103-B(12):1791-1801. PubMed ID: 34474593
[TBL] [Abstract][Full Text] [Related]
13. Analysis of wear in retrieved mobile and fixed bearing knee inserts.
Engh GA; Zimmerman RL; Parks NL; Engh CA
J Arthroplasty; 2009 Sep; 24(6 Suppl):28-32. PubMed ID: 19427754
[TBL] [Abstract][Full Text] [Related]
14. The influence of sterilization method on articular surface damage of retrieved cruciate-retaining tibial inserts.
Greulich MT; Roy ME; Whiteside LA
J Arthroplasty; 2012 Jun; 27(6):1085-93. PubMed ID: 22177798
[TBL] [Abstract][Full Text] [Related]
15. In vivo deterioration of tibial baseplate locking mechanisms in contemporary modular total knee components.
Engh GA; Lounici S; Rao AR; Collier MB
J Bone Joint Surg Am; 2001 Nov; 83(11):1660-5. PubMed ID: 11701788
[TBL] [Abstract][Full Text] [Related]
16. Minimal backside surface changes observed in retrieved acetabular liners.
Akbari A; Roy ME; Whiteside LA; Katerberg BJ; Schnettgoecke DJ
J Arthroplasty; 2011 Aug; 26(5):686-92. PubMed ID: 20875939
[TBL] [Abstract][Full Text] [Related]
17. Surface damage on open box posterior-stabilized polyethylene tibial inserts.
Silva M; Kabbash CA; Tiberi JV; Park SH; Reilly DT; Mahoney OM; Schmalzried TP
Clin Orthop Relat Res; 2003 Nov; (416):135-44. PubMed ID: 14646752
[TBL] [Abstract][Full Text] [Related]
18. Material and surface factors influencing backside fretting wear in total knee replacement tibial components.
Billi F; Sangiorgio SN; Aust S; Ebramzadeh E
J Biomech; 2010 May; 43(7):1310-5. PubMed ID: 20172525
[TBL] [Abstract][Full Text] [Related]
19. Knee wear measured in retrievals: a polished tray reduces insert wear.
Berry DJ; Currier JH; Mayor MB; Collier JP
Clin Orthop Relat Res; 2012 Jul; 470(7):1860-8. PubMed ID: 22314963
[TBL] [Abstract][Full Text] [Related]
20. Backside wear of modular ultra-high molecular weight polyethylene tibial inserts.
Conditt MA; Ismaily SK; Alexander JW; Noble PC
J Bone Joint Surg Am; 2004 May; 86(5):1031-7. PubMed ID: 15118049
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]