These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 21785984)

  • 1. Titanium release in serum of patients with different bone fixation implants and its interaction with serum biomolecules at physiological levels.
    Nuevo-Ordóñez Y; Montes-Bayón M; Blanco-González E; Paz-Aparicio J; Raimundez JD; Tejerina JM; Peña MA; Sanz-Medel A
    Anal Bioanal Chem; 2011 Nov; 401(9):2747-54. PubMed ID: 21785984
    [TBL] [Abstract][Full Text] [Related]  

  • 2. HPLC-ICPMS and stable isotope-labeled approaches to assess quantitatively Ti(IV) uptake by transferrin in human blood serum.
    Sarmiento-González A; Ruiz Encinar J; Cantarero-Roldán AM; Marchante-Gayón JM; Sanz-Medel A
    Anal Chem; 2008 Nov; 80(22):8702-11. PubMed ID: 18847283
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A novel method for speciation of Pt in human serum incubated with cisplatin, oxaliplatin and carboplatin by conjoint liquid chromatography on monolithic disks with UV and ICP-MS detection.
    Martinčič A; Cemazar M; Sersa G; Kovač V; Milačič R; Ščančar J
    Talanta; 2013 Nov; 116():141-8. PubMed ID: 24148385
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accurate determination of ultra-trace levels of Ti in blood serum using ICP-MS/MS.
    Balcaen L; Bolea-Fernandez E; Resano M; Vanhaecke F
    Anal Chim Acta; 2014 Jan; 809():1-8. PubMed ID: 24418127
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of the biological effect of Ti generated debris from metal implants: ions and nanoparticles.
    Soto-Alvaredo J; Blanco E; Bettmer J; Hevia D; Sainz RM; López Cháves C; Sánchez C; Llopis J; Sanz-Medel A; Montes-Bayón M
    Metallomics; 2014 Sep; 6(9):1702-8. PubMed ID: 25001216
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Analysis of soluble or titanium dioxide derived titanium levels in human whole blood: consensus from an inter-laboratory comparison.
    Koller D; Bramhall P; Devoy J; Goenaga-Infante H; Harrington CF; Leese E; Morton J; Nuñez S; Rogers J; Sampson B; Powell JJ
    Analyst; 2018 Nov; 143(22):5520-5529. PubMed ID: 30295302
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Titanium preferential binding sites in human serum transferrin at physiological concentrations.
    Nuevo-Ordoñez Y; Montes-Bayón M; Blanco González E; Sanz-Medel A
    Metallomics; 2011 Dec; 3(12):1297-303. PubMed ID: 22041858
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Convective interaction media monolithic chromatography with ICPMS and ultraperformance liquid chromatography-electrospray ionization MS detection: a powerful tool for speciation of aluminum in human serum at normal concentration levels.
    Murko S; Milacic R; Kralj B; Scancar J
    Anal Chem; 2009 Jun; 81(12):4929-36. PubMed ID: 19435331
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Protein quantitation using Ru-NHS ester tagging and isotope dilution high-pressure liquid chromatography-inductively coupled plasma mass spectrometry determination.
    Liu R; Lv Y; Hou X; Yang L; Mester Z
    Anal Chem; 2012 Mar; 84(6):2769-75. PubMed ID: 22324291
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Simultaneous determination of 19 triazine pesticides and degradation products in processed cereal samples from Chinese total diet study by isotope dilution-high performance liquid chromatography-linear ion trap mass spectrometry.
    Li P; Yang X; Miao H; Zhao Y; Liu W; Wu Y
    Anal Chim Acta; 2013 Jun; 781():63-71. PubMed ID: 23684466
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Measurement of titanium in hip-replacement patients by inductively coupled plasma optical emission spectroscopy.
    Harrington CF; McKibbin C; Rahanu M; Langton D; Taylor A
    Ann Clin Biochem; 2017 May; 54(3):362-369. PubMed ID: 27422134
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Anion-exchange high performance liquid chromatography hyphenated to inductively coupled plasma-isotope dilution-time-of-flight mass spectrometry for speciation analysis of metal complexes with metallothionein isoforms in gibel carp (Carassius auratus gibelio) exposed to environmental metal pollution.
    Infante HG; Van Campenhout K; Blust R; Adams FC
    J Chromatogr A; 2006 Jul; 1121(2):184-90. PubMed ID: 16678190
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Mercury speciation analysis in seafood by species-specific isotope dilution: method validation and occurrence data.
    Clémens S; Monperrus M; Donard OF; Amouroux D; Guérin T
    Anal Bioanal Chem; 2011 Nov; 401(9):2699-711. PubMed ID: 21533797
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Speciation of trace elements in human serum by micro anion exchange chromatography coupled with inductively coupled plasma mass spectrometry.
    Malavolta M; Piacenza F; Basso A; Giacconi R; Costarelli L; Pierpaoli S; Mocchegiani E
    Anal Biochem; 2012 Feb; 421(1):16-25. PubMed ID: 22155148
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A novel quantification strategy of transferrin and albumin in human serum by species-unspecific isotope dilution laser ablation inductively coupled plasma mass spectrometry (ICP-MS).
    Feng L; Zhang D; Wang J; Shen D; Li H
    Anal Chim Acta; 2015 Jul; 884():19-25. PubMed ID: 26073803
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Systematic studies on the determination of Hg-labelled proteins using laser ablation-ICPMS and isotope dilution analysis.
    Kutscher DJ; Fricker MB; Hattendorf B; Bettmer J; Günther D
    Anal Bioanal Chem; 2011 Nov; 401(9):2691-8. PubMed ID: 21773737
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The role of citrate, lactate and transferrin in determining titanium release from surgical devices into human serum.
    Curtin JP; Wang M; Cheng T; Jin L; Sun H
    J Biol Inorg Chem; 2018 May; 23(3):471-480. PubMed ID: 29623422
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Speciation of Al in human serum by convective-interaction media fast-monolithic chromatography with inductively coupled plasma mass spectrometric detection.
    Murko S; Milacic R; Scancar J
    J Inorg Biochem; 2007 Sep; 101(9):1234-41. PubMed ID: 17640734
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Accurate determination of human serum transferrin isoforms: Exploring metal-specific isotope dilution analysis as a quantitative proteomic tool.
    Busto ME; Montes-Bayón M; Sanz-Medel A
    Anal Chem; 2006 Dec; 78(24):8218-26. PubMed ID: 17165810
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Determination of the titanium content of human transferrin by inductively-coupled plasma-atomic-emission spectroscopy.
    Cardona A; Meléndez E
    Anal Bioanal Chem; 2006 Nov; 386(6):1689-93. PubMed ID: 17019577
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.