BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

227 related articles for article (PubMed ID: 21793166)

  • 1. Correlates on MSCT of paravalvular aortic regurgitation after transcatheter aortic valve implantation using the Medtronic CoreValve prosthesis.
    Schultz CJ; Tzikas A; Moelker A; Rossi A; Nuis RJ; Geleijnse MM; van Mieghem N; Krestin GP; de Feyter P; Serruys PW; de Jaegere PP
    Catheter Cardiovasc Interv; 2011 Sep; 78(3):446-55. PubMed ID: 21793166
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Aortic annulus dimensions and leaflet calcification from contrast MSCT predict the need for balloon post-dilatation after TAVI with the Medtronic CoreValve prosthesis.
    Schultz C; Rossi A; van Mieghem N; van der Boon R; Papadopoulou SL; van Domburg R; Moelker A; Mollet N; Krestin G; van Geuns RJ; Nieman K; de Feyter P; Serruys PW; de Jaegere P
    EuroIntervention; 2011 Sep; 7(5):564-72. PubMed ID: 21930460
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Prosthesis-Specific Predictors of Paravalvular Regurgitation after Transcatheter Aortic Valve Replacement: Impact of Calcification and Sizing on Balloon-Expandable versus Self-Expandable Transcatheter Heart Valves.
    Stähli BE; Nguyen-Kim TD; Gebhard C; Erhart L; Frauenfelder T; Tanner FC; Falk V; Landmesser U; Nietlispach F; Lüscher TF; Maier W; Binder RK
    J Heart Valve Dis; 2015 Jan; 24(1):10-21. PubMed ID: 26182615
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Preparatory balloon aortic valvuloplasty during transcatheter aortic valve implantation for improved valve sizing.
    Patsalis PC; Al-Rashid F; Neumann T; Plicht B; Hildebrandt HA; Wendt D; Thielmann M; Jakob HG; Heusch G; Erbel R; Kahlert P
    JACC Cardiovasc Interv; 2013 Sep; 6(9):965-71. PubMed ID: 24050862
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Predictors of moderate-to-severe paravalvular aortic regurgitation immediately after CoreValve implantation and the impact of postdilatation.
    Takagi K; Latib A; Al-Lamee R; Mussardo M; Montorfano M; Maisano F; Godino C; Chieffo A; Alfieri O; Colombo A
    Catheter Cardiovasc Interv; 2011 Sep; 78(3):432-43. PubMed ID: 21793168
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Prediction of paravalvular leakage after transcatheter aortic valve implantation.
    Di Martino LF; Vletter WB; Ren B; Schultz C; Van Mieghem NM; Soliman OI; Di Biase M; de Jaegere PP; Geleijnse ML
    Int J Cardiovasc Imaging; 2015 Oct; 31(7):1461-8. PubMed ID: 26187523
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determinants of aortic regurgitation after transcatheter aortic valve implantation. An observational study using multi-slice computed tomography-guided sizing.
    Rahhab Z; El Faquir N; Rodríguez-Olivares R; Ren C; van Mieghem N; Geleijnse ML; Schultz C; van Domburg R; de Jaegere PP
    J Cardiovasc Surg (Torino); 2017 Aug; 58(4):598-605. PubMed ID: 28128540
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Intraoperative 2D and 3D transoesophageal echocardiographic predictors of aortic regurgitation after transcatheter aortic valve implantation.
    Gripari P; Ewe SH; Fusini L; Muratori M; Ng AC; Cefalù C; Delgado V; Schalij MJ; Bax JJ; Marsan NA; Tamborini G; Pepi M
    Heart; 2012 Aug; 98(16):1229-36. PubMed ID: 22826560
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Assessment of the aortic annulus by multislice computed tomography, contrast aortography, and trans-thoracic echocardiography in patients referred for transcatheter aortic valve implantation.
    Tzikas A; Schultz CJ; Piazza N; Moelker A; Van Mieghem NM; Nuis RJ; van Geuns RJ; Geleijnse ML; Serruys PW; de Jaegere PP
    Catheter Cardiovasc Interv; 2011 May; 77(6):868-75. PubMed ID: 20824762
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Incidence and severity of paravalvular aortic regurgitation with multidetector computed tomography nominal area oversizing or undersizing after transcatheter heart valve replacement with the Sapien 3: a comparison with the Sapien XT.
    Yang TH; Webb JG; Blanke P; Dvir D; Hansson NC; Nørgaard BL; Thompson CR; Thomas M; Wendler O; Vahanian A; Himbert D; Kodali SK; Hahn RT; Thourani VH; Schymik G; Precious B; Berger A; Wood DA; Pibarot P; Rodés-Cabau J; Jaber WA; Leon MB; Walther T; Leipsic J
    JACC Cardiovasc Interv; 2015 Mar; 8(3):462-471. PubMed ID: 25790764
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Optimal prosthesis sizing in transcatheter aortic valve implantation by exclusive use of three-dimensional transoesophageal echocardiography.
    Kretzschmar D; Lauten A; Goebel B; Doenst T; Poerner TC; Ferrari M; Figulla HR; Hamadanchi A
    Clin Physiol Funct Imaging; 2016 Mar; 36(2):99-105. PubMed ID: 25316588
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Assessment of Post-Procedural Aortic Regurgitation After TAVR: An Intraprocedural TEE Study.
    Mihara H; Shibayama K; Jilaihawi H; Itabashi Y; Berdejo J; Utsunomiya H; Siegel RJ; Makkar RR; Shiota T
    JACC Cardiovasc Imaging; 2015 Sep; 8(9):993-1003. PubMed ID: 26319501
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Three-dimensional multidetector computed tomography versus conventional 2-dimensional transesophageal echocardiography for annular sizing in transcatheter aortic valve replacement: Influence on postprocedural paravalvular aortic regurgitation.
    Hansson NC; Thuesen L; Hjortdal VE; Leipsic J; Andersen HR; Poulsen SH; Webb JG; Christiansen EH; Rasmussen LE; Krusell LR; Terp K; Klaaborg KE; Tang M; Lassen JF; Bøtker HE; Nørgaard BL
    Catheter Cardiovasc Interv; 2013 Nov; 82(6):977-86. PubMed ID: 23703899
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Determinants of significant paravalvular regurgitation after transcatheter aortic valve: implantation impact of device and annulus discongruence.
    Détaint D; Lepage L; Himbert D; Brochet E; Messika-Zeitoun D; Iung B; Vahanian A
    JACC Cardiovasc Interv; 2009 Sep; 2(9):821-7. PubMed ID: 19778769
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Impact of aortic regurgitation after transcatheter aortic valve implantation: results from the REVIVAL trial.
    Yared K; Garcia-Camarero T; Fernandez-Friera L; Llano M; Durst R; Reddy AA; O'Neill WW; Picard MH
    JACC Cardiovasc Imaging; 2012 May; 5(5):469-77. PubMed ID: 22595154
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Transcarotid aortic valve-in-valve implantation for degenerated stentless aortic root conduits with severe regurgitation: a case series.
    Huber C; Praz F; O'Sullivan CJ; Langhammer B; Gloekler S; Stortecky S; von Allmen RS; Meier B; Carrel T; Englberger L; Windecker S; Wenaweser P
    Interact Cardiovasc Thorac Surg; 2015 Jun; 20(6):694-700. PubMed ID: 25776924
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Impact of three-dimensional transesophageal echocardiography on prosthesis sizing for transcatheter aortic valve implantation.
    Husser O; Rauch S; Endemann DH; Resch M; Nunez J; Bodi V; Hilker M; Schmid C; Riegger GA; Luchner A; Hengstenberg C
    Catheter Cardiovasc Interv; 2012 Nov; 80(6):956-63. PubMed ID: 22419651
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Relationship of aortic annular eccentricity and paravalvular regurgitation post transcatheter aortic valve implantation with CoreValve.
    Wong DT; Bertaso AG; Liew GY; Thomson VS; Cunnington MS; Richardson JD; Gooley R; Lockwood S; Meredith IT; Worthley MI; Worthley SG
    J Invasive Cardiol; 2013 Apr; 25(4):190-5. PubMed ID: 23549493
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The extent of aortic annulus calcification is a predictor of postprocedural eccentricity and paravalvular regurgitation: a pre- and postinterventional cardiac computed tomography angiography study.
    Bekeredjian R; Bodingbauer D; Hofmann NP; Greiner S; Schuetz M; Geis NA; Kauczor HU; Bryant M; Chorianopoulos E; Pleger ST; Mereles D; Katus HA; Korosoglou G
    J Invasive Cardiol; 2015 Mar; 27(3):172-80. PubMed ID: 25740972
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Prosthesis-patient mismatch after transcatheter aortic valve implantation: impact of 2D-transthoracic echocardiography versus 3D-transesophageal echocardiography.
    da Silva C; Sahlen A; Winter R; Bäck M; Rück A; Settergren M; Manouras A; Shahgaldi K
    Int J Cardiovasc Imaging; 2014 Dec; 30(8):1549-57. PubMed ID: 25102782
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.