These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
306 related articles for article (PubMed ID: 21796492)
1. High-intensity focused ultrasound (HIFU)-assisted hepatic resection in an animal model. Gandini A; Melodelima D; Schenone F; N'Djin AW; Chapelon JY; Rivoire M Ann Surg Oncol; 2012 Jul; 19 Suppl 3():S447-54. PubMed ID: 21796492 [TBL] [Abstract][Full Text] [Related]
2. Assisted hepatic resection using a toroidal HIFU device: an in vivo comparative study in pig. N'Djin WA; Melodelima D; Schenone F; Rivoire M; Chapelon JY Med Phys; 2011 Apr; 38(4):1769-78. PubMed ID: 21626911 [TBL] [Abstract][Full Text] [Related]
3. Efficacy of high-intensity focused ultrasound-assisted hepatic resection (HIFU-AR) on blood loss reduction in patients with liver metastases requiring hepatectomy: study protocol for a randomized controlled trial. Dupré A; Pérol D; Blanc E; Peyrat P; Basso V; Chen Y; Vincenot J; Kocot A; Melodelima D; Rivoire M Trials; 2017 Feb; 18(1):57. PubMed ID: 28166812 [TBL] [Abstract][Full Text] [Related]
4. The vessel sealing system (LigaSure) in hepatic resection: a randomized controlled trial. Ikeda M; Hasegawa K; Sano K; Imamura H; Beck Y; Sugawara Y; Kokudo N; Makuuchi M Ann Surg; 2009 Aug; 250(2):199-203. PubMed ID: 19638927 [TBL] [Abstract][Full Text] [Related]
5. Liver resection using a soft-coagulation system without the Pringle maneuver. Okamoto K; Koyama I; Toshimitsu Y; Aikawa M; Okada K; Ueno Y; Miyazawa M Hepatogastroenterology; 2012 May; 59(115):875-7. PubMed ID: 22024227 [TBL] [Abstract][Full Text] [Related]
6. Evaluation of total hepatic vascular exclusion and pringle maneuver in liver resection. Kimura F; Miyazaki M; Suwa T; Sugiura T; Shinoda T; Itoh H; Nakagawa K; Ambiru S; Shimizu H; Yoshitome H Hepatogastroenterology; 2002; 49(43):225-30. PubMed ID: 11941961 [TBL] [Abstract][Full Text] [Related]
7. Usefulness of LigaSure for liver resection: analysis by randomized clinical trial. Saiura A; Yamamoto J; Koga R; Sakamoto Y; Kokudo N; Seki M; Yamaguchi T; Yamaguchi T; Muto T; Makuuchi M Am J Surg; 2006 Jul; 192(1):41-5. PubMed ID: 16769273 [TBL] [Abstract][Full Text] [Related]
8. Usefulness of the combination procedure of crash clamping and vessel sealing for hepatic resection. Nanashima A; Tobinaga S; Abo T; Nonaka T; Sawai T; Nagayasu T J Surg Oncol; 2010 Aug; 102(2):179-83. PubMed ID: 20648591 [TBL] [Abstract][Full Text] [Related]
9. A new single-instrument technique for parenchyma division and hemostasis in liver resection: a clinical feasibility study. Burdío F; Grande L; Berjano E; Martinez-Serrano M; Poves I; Burdío JM; Navarro A; Güemes A Am J Surg; 2010 Dec; 200(6):e75-80. PubMed ID: 20864082 [TBL] [Abstract][Full Text] [Related]
10. In-line radiofrequency ablation to minimize blood loss in hepatic parenchymal transection. Haghighi KS; Wang F; King J; Daniel S; Morris DL Am J Surg; 2005 Jul; 190(1):43-7. PubMed ID: 15972170 [TBL] [Abstract][Full Text] [Related]
11. Radiofrequency assisted liver resection: analysis of 604 consecutive cases. Pai M; Frampton AE; Mikhail S; Resende V; Kornasiewicz O; Spalding DR; Jiao LR; Habib NA Eur J Surg Oncol; 2012 Mar; 38(3):274-80. PubMed ID: 22209064 [TBL] [Abstract][Full Text] [Related]
12. Selective and unselective clamping in cirrhotic liver. Takayama T; Makuuchi M; Inoue K; Sakamoto Y; Kubota K; Harihara Y Hepatogastroenterology; 1998; 45(20):376-80. PubMed ID: 9638410 [TBL] [Abstract][Full Text] [Related]
13. A radiofrequency-assisted device for bloodless rapid transection of the liver: a comparative study in a pig liver model. Burdío F; Navarro A; Berjano E; Sousa R; Burdío JM; Güemes A; Subiró J; Gonzalez A; Cruz I; Castiella T; Tejero E; Lozano R; Grande L; de Gregorio MA Eur J Surg Oncol; 2008 May; 34(5):599-605. PubMed ID: 17614248 [TBL] [Abstract][Full Text] [Related]
14. Methods of vascular control technique during liver resection: a comprehensive review. Lau WY; Lai EC; Lau SH Hepatobiliary Pancreat Dis Int; 2010 Oct; 9(5):473-81. PubMed ID: 20943455 [TBL] [Abstract][Full Text] [Related]
15. Randomized clinical trial of liver resection with and without hepatic pedicle clamping. Capussotti L; Muratore A; Ferrero A; Massucco P; Ribero D; Polastri R Br J Surg; 2006 Jun; 93(6):685-9. PubMed ID: 16703653 [TBL] [Abstract][Full Text] [Related]
16. Tissue preserving hepatectomy by a vessel sealing device. Tepetes K; Christodoulidis G; Spyridakis EM; Chatzitheofilou C J Surg Oncol; 2008 Feb; 97(2):165-8. PubMed ID: 17786962 [TBL] [Abstract][Full Text] [Related]
17. Usefulness of vessel-sealing devices combined with crush clamping method for hepatectomy: a retrospective cohort study. Nanashima A; Abo T; Arai J; Takagi K; Matsumoto H; Takeshita H; Tsuchiya T; Nagayasu T Int J Surg; 2013; 11(9):891-7. PubMed ID: 23954369 [TBL] [Abstract][Full Text] [Related]
18. Extraparenchymal control of hepatic veins during mesohepatectomy. Giuliante F; Nuzzo G; Ardito F; Vellone M; De Cosmo G; Giovannini I J Am Coll Surg; 2008 Mar; 206(3):496-502. PubMed ID: 18308221 [TBL] [Abstract][Full Text] [Related]
20. Precoagulation minimizes blood loss during standardized hepatic resection in an experimental model. Fioole B; van der Bilt JD; Elias SG; de Hoog J; Borel Rinkes IH Br J Surg; 2005 Nov; 92(11):1409-16. PubMed ID: 16231280 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]