These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 21802240)

  • 1. Knitted nitinol represents a new generation of constrictive external vein graft meshes.
    Zilla P; Moodley L; Wolf MF; Bezuidenhout D; Sirry MS; Rafiee N; Lichtenberg W; Black M; Franz T
    J Vasc Surg; 2011 Nov; 54(5):1439-50. PubMed ID: 21802240
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Utilization of shape memory in external vein-graft meshes allows extreme diameter constriction for suppressing intimal hyperplasia: a non-human primate study.
    Zilla P; Wolf M; Rafiee N; Moodley L; Bezuidenhout D; Black M; Human P; Franz T
    J Vasc Surg; 2009 Jun; 49(6):1532-42. PubMed ID: 19497517
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Protective constriction of coronary vein grafts with knitted nitinol.
    Moodley L; Franz T; Human P; Wolf MF; Bezuidenhout D; Scherman J; Zilla P
    Eur J Cardiothorac Surg; 2013 Jul; 44(1):64-71. PubMed ID: 23295444
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Constrictive external nitinol meshes inhibit vein graft intimal hyperplasia in nonhuman primates.
    Zilla P; Human P; Wolf M; Lichtenberg W; Rafiee N; Bezuidenhout D; Samodien N; Schmidt C; Franz T
    J Thorac Cardiovasc Surg; 2008 Sep; 136(3):717-25. PubMed ID: 18805277
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Remodeling leads to distinctly more intimal hyperplasia in coronary than in infrainguinal vein grafts.
    Zilla P; Moodley L; Scherman J; Krynauw H; Kortsmit J; Human P; Wolf MF; Franz T
    J Vasc Surg; 2012 Jun; 55(6):1734-41. PubMed ID: 22386141
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A novel biodegradable external mesh stent improved long-term patency of vein grafts by inhibiting intimal-medial hyperplasia in an experimental canine model.
    Sato A; Kawamoto S; Watanabe M; Suzuki Y; Takahashi G; Masaki N; Kumagai K; Saijo Y; Tabayashi K; Saiki Y
    Gen Thorac Cardiovasc Surg; 2016 Jan; 64(1):1-9. PubMed ID: 26419247
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A new design concept for knitted external vein-graft support mesh.
    Singh C; Wang X
    J Mech Behav Biomed Mater; 2015 Aug; 48():125-133. PubMed ID: 25916819
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Tailored sizes of constrictive external vein meshes for coronary artery bypass surgery.
    Franz T; Human P; Dobner S; Reddy BD; Black M; Ilsley H; Wolf MF; Bezuidenhout D; Moodley L; Zilla P
    Biomaterials; 2010 Dec; 31(35):9301-9. PubMed ID: 20864157
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A computational study of knitted Nitinol meshes for their prospective use as external vein reinforcement.
    van der Merwe H; Daya Reddy B; Zilla P; Bezuidenhout D; Franz T
    J Biomech; 2008; 41(6):1302-9. PubMed ID: 18328487
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Compliance mismatch and formation of distal anastomotic intimal hyperplasia in externally stiffened and lumen-adapted venous grafts.
    Trubel W; Schima H; Moritz A; Raderer F; Windisch A; Ullrich R; Windberger U; Losert U; Polterauer P
    Eur J Vasc Endovasc Surg; 1995 Nov; 10(4):415-23. PubMed ID: 7489209
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The use of mesh-tube-constricted dilated or varicose veins as arterial bypass conduit.
    Moritz A; Raderer F; Magometschnigg H; Trubel W; Ullrich R; Laufer G; Staudacher M
    Thorac Cardiovasc Surg; 1992 Dec; 40(6):356-60. PubMed ID: 1290183
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Highly flexible nitinol mesh to encase aortocoronary saphenous vein grafts: first clinical experiences and angiographic results nine months postoperatively.
    Schoettler J; Jussli-Melchers J; Grothusen C; Stracke L; Schoeneich F; Stohn S; Hoffmann G; Cremer J
    Interact Cardiovasc Thorac Surg; 2011 Oct; 13(4):396-400. PubMed ID: 21724659
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Compliance and formation of distal anastomotic intimal hyperplasia in Dacron mesh tube constricted veins used as arterial bypass grafts.
    Trubel W; Moritz A; Schima H; Raderer F; Scherer R; Ullrich R; Losert U; Polterauer P
    ASAIO J; 1994; 40(3):M273-8. PubMed ID: 8555523
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Braided or laser-cut self-expanding nitinol stents for the common femoral vein in patients with post-thrombotic syndrome.
    Moeri L; Lichtenberg M; Gnanapiragasam S; Barco S; Sebastian T
    J Vasc Surg Venous Lymphat Disord; 2021 May; 9(3):760-769. PubMed ID: 32890743
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Mechanical and histologic changes in canine vein grafts.
    Dobrin PB; Littooy FN; Golan J; Blakeman B; Fareed J
    J Surg Res; 1988 Mar; 44(3):259-65. PubMed ID: 3343824
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Prevention of neointimal hyperplasia associated with modified stretch expanded polytetrafluoroethylene hemodialysis grafts (Gore) in an experimental preclinical study in swine.
    Gessaroli M; Bombardi C; Giunti M; Bacci ML
    J Vasc Surg; 2012 Jan; 55(1):192-202. PubMed ID: 21944911
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Extravascular perivenous fibrin support leads to aneurysmal degeneration and intimal hyperplasia in arterialized vein grafts in the rat.
    Stojanovic T; El-Sayed Ahmad A; Didilis V; Ali O; Popov AF; Danner BC; Seipelt R; Dörge H; Schöndube FA
    Langenbecks Arch Surg; 2009 Mar; 394(2):357-62. PubMed ID: 18509670
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Long-term reduction of medial and intimal thickening in porcine saphenous vein grafts with a polyglactin biodegradable external sheath.
    Vijayan V; Shukla N; Johnson JL; Gadsdon P; Angelini GD; Smith FC; Baird R; Jeremy JY
    J Vasc Surg; 2004 Nov; 40(5):1011-9. PubMed ID: 15557918
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effects of polypropylene mesh on femoral artery and femoral vein in mesh repair.
    Sulaimanov M; Genc V; Cakmak A; Orozakunov E; Akkus S; Hazinedaroglu S; Kuterdem E
    Hernia; 2010 Dec; 14(6):629-34. PubMed ID: 20835909
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effects of external wrapping and increased blood flow on atrophy of the baboon iliac artery.
    Min SK; Kenagy RD; Jeanette JP; Clowes AW
    J Vasc Surg; 2008 May; 47(5):1039-47. PubMed ID: 18358668
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.