These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
206 related articles for article (PubMed ID: 21802910)
21. Electrocatalytic oxidation of NADH at electrogenerated NAD+ oxidation product immobilized onto multiwalled carbon nanotubes/ionic liquid nanocomposite: application to ethanol biosensing. Teymourian H; Salimi A; Hallaj R Talanta; 2012 Feb; 90():91-8. PubMed ID: 22340121 [TBL] [Abstract][Full Text] [Related]
22. Electrochemical behavior of rutin on a multi-walled carbon nanotube and ionic liquid composite film modified electrode. Liu X; Li L; Zhao X; Lu X Colloids Surf B Biointerfaces; 2010 Nov; 81(1):344-9. PubMed ID: 20708387 [TBL] [Abstract][Full Text] [Related]
23. [Preparation of OMC-Au/L-Lysine/Au modified glassy carbon electrode and the study on its detection response to hydroquinone and catechol]. Zhou YY; Tang L; Li Z; Liu YY; Yang GD; Wu MS; Lei XX; Zheng GM Huan Jing Ke Xue; 2013 Mar; 34(3):1211-7. PubMed ID: 23745436 [TBL] [Abstract][Full Text] [Related]
24. Application of multi-walled carbon nanotubes modified carbon ionic liquid electrode for electrocatalytic oxidation of dopamine. Li Y; Liu X; Liu X; Mai N; Li Y; Wei W; Cai Q Colloids Surf B Biointerfaces; 2011 Nov; 88(1):402-6. PubMed ID: 21831611 [TBL] [Abstract][Full Text] [Related]
25. Cobalt-iron selenides embedded in porous carbon nanofibers for simultaneous electrochemical detection of trace of hydroquinone, catechol and resorcinol. Yin D; Liu J; Bo X; Guo L Anal Chim Acta; 2020 Jan; 1093():35-42. PubMed ID: 31735213 [TBL] [Abstract][Full Text] [Related]
26. Nonenzymatic glucose sensor based on ultrasonic-electrodeposition of bimetallic PtM (M=Ru, Pd and Au) nanoparticles on carbon nanotubes-ionic liquid composite film. Xiao F; Zhao F; Mei D; Mo Z; Zeng B Biosens Bioelectron; 2009 Aug; 24(12):3481-6. PubMed ID: 19524431 [TBL] [Abstract][Full Text] [Related]
27. The Cu-MOF-199/single-walled carbon nanotubes modified electrode for simultaneous determination of hydroquinone and catechol with extended linear ranges and lower detection limits. Zhou J; Li X; Yang L; Yan S; Wang M; Cheng D; Chen Q; Dong Y; Liu P; Cai W; Zhang C Anal Chim Acta; 2015 Oct; 899():57-65. PubMed ID: 26547493 [TBL] [Abstract][Full Text] [Related]
28. Simultaneous Detection of Hydroquinone and Catechol Using Platinum Nanoparticles Decorated Graphene/Poly-Cyclodextrin/Multiwalled Carbon Nanotubes (MWCNTs) Nanocomposite Based Biosensor. Huang X; Deng X; Qi W; Wu D J Nanosci Nanotechnol; 2018 Dec; 18(12):8118-8123. PubMed ID: 30189928 [TBL] [Abstract][Full Text] [Related]
29. Electrochemical sensor based on Ce-MOF/carbon nanotube composite for the simultaneous discrimination of hydroquinone and catechol. Huang H; Chen Y; Chen Z; Chen J; Hu Y; Zhu JJ J Hazard Mater; 2021 Aug; 416():125895. PubMed ID: 34492833 [TBL] [Abstract][Full Text] [Related]
30. A Cu-functionalized MOF and multi-walled carbon nanotube composite modified electrode for the simultaneous determination of hydroquinone and catechol. Zhang HJ; Zou X; Chen WY; Sun Q; Gao EQ Anal Methods; 2022 Oct; 14(40):3961-3969. PubMed ID: 36173377 [TBL] [Abstract][Full Text] [Related]
31. A novel hydrogen peroxide biosensor based on the Sn-ZnNPs/MWNTs nanocomposite film. Sun A; Zhao H; Zheng J Talanta; 2012 Jan; 88():259-64. PubMed ID: 22265496 [TBL] [Abstract][Full Text] [Related]
34. Microbial synthesis of antimony sulfide to prepare catechol and hydroquinone electrochemical sensor by pyrolysis and carbonization. Jiang X; Yuan Y; Zhao X; Wan C; Duan Y; Wu C Environ Res; 2024 Jul; 252(Pt 1):118860. PubMed ID: 38582422 [TBL] [Abstract][Full Text] [Related]
35. [Electrocatalytic oxidation of SMZ at multi-wall carbon nanotubes-Nafion modified glassy carbon electrode and its electrochemical determination application]. Sun YQ; You W; Gao ZN Yao Xue Xue Bao; 2008 Apr; 43(4):396-401. PubMed ID: 18664203 [TBL] [Abstract][Full Text] [Related]
36. Development of sensitive amperometric hydrogen peroxide sensor using a CuNPs/MB/MWCNT-C60-Cs-IL nanocomposite modified glassy carbon electrode. Roushani M; Bakyas K; Zare Dizajdizi B Mater Sci Eng C Mater Biol Appl; 2016 Jul; 64():54-60. PubMed ID: 27127028 [TBL] [Abstract][Full Text] [Related]
37. Simultaneous electrochemical detection of antioxidants Hydroquinone, Mono-Tert-butyl hydroquinone and catechol in food and polymer samples using ZnO@MnO Movahed V; Arshadi L; Ghanavati M; Nejad EM; Mohagheghzadeh Z; Rezaei M Food Chem; 2023 Mar; 403():134286. PubMed ID: 36174346 [TBL] [Abstract][Full Text] [Related]
38. Synthesis of Graphene Oxide-Coupled CoNi Bimetallic MOF Nanocomposites for the Simultaneous Analysis of Catechol and Hydroquinone. Zheng S; Zhang N; Li L; Liu T; Zhang Y; Tang J; Guo J; Su S Sensors (Basel); 2023 Aug; 23(15):. PubMed ID: 37571740 [TBL] [Abstract][Full Text] [Related]
39. Voltammetric simultaneous determination of catechol and hydroquinone using a glassy carbon electrode modified with a ternary hybrid material composed of reduced graphene oxide, magnetite nanoparticles and gold nanoparticles. Kong FY; Li RF; Yao L; Wang ZX; Li HY; Lv WX; Wang W Mikrochim Acta; 2019 Feb; 186(3):177. PubMed ID: 30771082 [TBL] [Abstract][Full Text] [Related]
40. A voltammetric sensor for simultaneous determination of hydroquinone and catechol by using a heterojunction prepared from gold nanoparticle and graphitic carbon nitride. Guo H; Shen Y; Ouyang H; Long Y; Li W Mikrochim Acta; 2019 Nov; 186(12):819. PubMed ID: 31748881 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]