These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 21803607)

  • 1. Retrograde nailing versus locking plate osteosynthesis of proximal humeral fractures: a biomechanical study.
    Dietz SO; Hartmann F; Schwarz T; Nowak TE; Enders A; Kuhn S; Hofmann A; Rommens PM
    J Shoulder Elbow Surg; 2012 May; 21(5):618-24. PubMed ID: 21803607
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Angle-fixed plate fixation or double-plate osteosynthesis in fractures of the proximal humerus: a biomechanical study].
    Hessmann MH; Korner J; Hofmann A; Sternstein W; Rommens PM
    Biomed Tech (Berl); 2008 Jun; 53(3):130-7. PubMed ID: 18601621
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Screw augmentation reduces motion at the bone-implant interface: a biomechanical study of locking plate fixation of proximal humeral fractures.
    Schliemann B; Seifert R; Rosslenbroich SB; Theisen C; Wähnert D; Raschke MJ; Weimann A
    J Shoulder Elbow Surg; 2015 Dec; 24(12):1968-73. PubMed ID: 26255200
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of Calcar Screw Use in Surgical Neck Fractures of the Proximal Humerus With Unstable Medial Support: A Biomechanical Study.
    Bai L; Fu Z; An S; Zhang P; Zhang D; Jiang B
    J Orthop Trauma; 2014 Aug; 28(8):452-7. PubMed ID: 24662994
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Proximal humerus fracture rotational stability after fixation using a locking plate or a fixed-angle locked nail: the role of implant stiffness.
    Foruria AM; Carrascal MT; Revilla C; Munuera L; Sanchez-Sotelo J
    Clin Biomech (Bristol, Avon); 2010 May; 25(4):307-11. PubMed ID: 20153916
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biomechanical effects of calcar screws and bone block augmentation on medial support in locked plating of proximal humeral fractures.
    Katthagen JC; Schwarze M; Meyer-Kobbe J; Voigt C; Hurschler C; Lill H
    Clin Biomech (Bristol, Avon); 2014 Aug; 29(7):735-41. PubMed ID: 24997810
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Biomechanical investigation of fixed-angle plate osteosynthesis of the proximal humerus].
    Röderer G; AbouElsoud M; Gebhard F; Claes L; Aschoff AJ; Kinzl L
    Unfallchirurg; 2010 Feb; 113(2):133-8. PubMed ID: 20024525
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The role of medial comminution and calcar restoration in varus collapse of proximal humeral fractures treated with locking plates.
    Ponce BA; Thompson KJ; Raghava P; Eberhardt AW; Tate JP; Volgas DA; Stannard JP
    J Bone Joint Surg Am; 2013 Aug; 95(16):e113(1-7). PubMed ID: 23965707
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanical comparison of a proximal humeral locking plate using two methods of head fixation.
    Schumer RA; Muckley KL; Markert RJ; Prayson MJ; Heflin J; Konstantakos EK; Goswami T
    J Shoulder Elbow Surg; 2010 Jun; 19(4):495-501. PubMed ID: 20189837
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Medial support by fibula bone graft in angular stable plate fixation of proximal humeral fractures: an in vitro study with synthetic bone.
    Osterhoff G; Baumgartner D; Favre P; Wanner GA; Gerber H; Simmen HP; Werner CM
    J Shoulder Elbow Surg; 2011 Jul; 20(5):740-6. PubMed ID: 21330155
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Locked plate fixation and intramedullary nailing for proximal humerus fractures: a biomechanical evaluation.
    Hessmann MH; Hansen WS; Krummenauer F; Pol TF; Rommens P
    J Trauma; 2005 Jun; 58(6):1194-201. PubMed ID: 15995470
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Locking plates improve torsional resistance in the stabilization of three-part proximal humeral fractures.
    Weinstein DM; Bratton DR; Ciccone WJ; Elias JJ
    J Shoulder Elbow Surg; 2006; 15(2):239-43. PubMed ID: 16517372
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Primary stability in locking plate fixation for proximal humeral fractures may be increased by using an additional nail osteosynthesis in combination with locking plate osteosynthesis-A biomechanical comparison.
    Schöbel T; Gemkow M; Wendler T; Schleifenbaum S; Löffler S; Theopold J; Hepp P
    Clin Biomech (Bristol, Avon); 2024 Apr; 114():106235. PubMed ID: 38552372
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Two-part surgical neck fractures of the proximal part of the humerus. A biomechanical evaluation of two fixation techniques.
    Edwards SL; Wilson NA; Zhang LQ; Flores S; Merk BR
    J Bone Joint Surg Am; 2006 Oct; 88(10):2258-64. PubMed ID: 17015605
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Are locking screws advantageous with plate fixation of humeral shaft fractures? A biomechanical analysis of synthetic and cadaveric bone.
    O'Toole RV; Andersen RC; Vesnovsky O; Alexander M; Topoleski LD; Nascone JW; Sciadini MF; Turen C; Eglseder WA
    J Orthop Trauma; 2008; 22(10):709-15. PubMed ID: 18978547
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biomechanical comparison of screw-based zones of a spatial subchondral support plate for proximal humerus fractures.
    Jabran A; Peach C; Zou Z; Ren L
    Proc Inst Mech Eng H; 2019 Mar; 233(3):372-382. PubMed ID: 30700217
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures.
    Röderer G; Scola A; Schmölz W; Gebhard F; Windolf M; Hofmann-Fliri L
    Injury; 2013 Oct; 44(10):1327-32. PubMed ID: 23769470
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A comparative biomechanical analysis of implants for the stabilization of proximal humerus fractures.
    Füchtmeier B; May R; Fierlbeck J; Hammer J; Nerlich M
    Technol Health Care; 2006; 14(4-5):261-70. PubMed ID: 17065749
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effect of long calcar screws on the primary stability of 3-part, varus impacted proximal humeral fractures compared to short calcar screws: a real fracture simulation study.
    Ott N; Hackl M; Prescher A; Scaal M; Lanzerath F; Müller LP; Wegmann K
    Arch Orthop Trauma Surg; 2023 May; 143(5):2485-2491. PubMed ID: 35635575
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Hybrid blade and locking plate fixation for proximal humerus fractures: a comparative biomechanical analysis.
    Jabran A; Peach C; Zou Z; Ren L
    Biomed Eng Online; 2018 Jan; 17(1):10. PubMed ID: 29370867
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.