These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 21808386)

  • 1. Integrated mechano-optical hydrogen gas sensor using cantilever bending readout with a Si3N4 grated waveguide.
    Pham SV; Dijkstra M; van Wolferen HA; Pollnau M; Krijnen GJ; Hoekstra HJ
    Opt Lett; 2011 Aug; 36(15):3003-5. PubMed ID: 21808386
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Improved Optical Waveguide Microcantilever for Integrated Nanomechanical Sensor.
    Jing Y; Fan G; Wang R; Zhang Z; Cai X; Wei J; Chen X; Li H; Li Y
    Sensors (Basel); 2019 Oct; 19(19):. PubMed ID: 31597318
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A cantilever sensor with an integrated optical readout for detection of enzymatically produced homocysteine.
    Koev ST; Fernandes R; Bentley WE; Ghodssi R
    IEEE Trans Biomed Circuits Syst; 2009 Dec; 3(6):415-23. PubMed ID: 23853289
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Integrated optical readout using a hybrid plasmonic directional coupler in water.
    Li RZ; Yu Y; Zhang XY; Zhang T
    Appl Opt; 2017 Sep; 56(25):7230-7236. PubMed ID: 29047990
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Suspended ultra-small disk resonator on silicon for optical sensing.
    Wang X; Guan X; Huang Q; Zheng J; Shi Y; Dai D
    Opt Lett; 2013 Dec; 38(24):5405-8. PubMed ID: 24343002
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biophotonic sensors with integrated Si
    Kohler D; Schindler G; Hahn L; Milvich J; Hofmann A; Länge K; Freude W; Koos C
    Light Sci Appl; 2021 Mar; 10(1):64. PubMed ID: 33767136
    [TBL] [Abstract][Full Text] [Related]  

  • 7. All-fiber microcantilever sensor monitored by a low-cost fiber-to-tip structure with subnanometer resolution.
    Su L; Elliott SR
    Opt Lett; 2010 Apr; 35(8):1212-4. PubMed ID: 20410970
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Demonstration of microcantilever array with simultaneous readout using an in-plane photonic transduction method.
    Hu W; Anderson R; Qian Y; Song J; Noh JW; Kim S; Nordin GP
    Rev Sci Instrum; 2009 Aug; 80(8):085101. PubMed ID: 19725675
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Optical Planar Waveguide Sensor with Integrated Digitally-Printed Light Coupling-in and Readout Elements.
    Alamán J; López-Valdeolivas M; Alicante R; Sánchez-Somolinos C
    Sensors (Basel); 2019 Jun; 19(13):. PubMed ID: 31252582
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A Paper Based Milli-Cantilever Sensor for Detecting Hydrocarbon Gases via Smartphone Camera.
    Qin X; Wu T; Zhu Y; Shan X; Liu C; Tao N
    Anal Chem; 2020 Jun; 92(12):8480-8486. PubMed ID: 32349475
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Design and sensing properties of an integrated optical gas sensor based on a multilayer structure.
    Airoudj A; Debarnot D; Bêche B; Poncin-Epaillard F
    Anal Chem; 2008 Dec; 80(23):9188-94. PubMed ID: 19551985
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Top-down silicon microcantilever with coupled bottom-up silicon nanowire for enhanced mass resolution.
    Vidal-Álvarez G; Agustí J; Torres F; Abadal G; Barniol N; Llobet J; Sansa M; Fernández-Regúlez M; Pérez-Murano F; San Paulo Á; Gottlieb O
    Nanotechnology; 2015 Apr; 26(14):145502. PubMed ID: 25786069
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Design of waveguide-integrated graphene devices for photonic gas sensing.
    Cheng Z; Goda K
    Nanotechnology; 2016 Dec; 27(50):505206. PubMed ID: 27855120
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Experimental setup for characterization of self-actuated microcantilevers with piezoresistive readout for chemical recognition of volatile substances.
    Filenko D; Ivanov T; Volland BE; Ivanova K; Rangelow IW; Nikolov N; Gotszalk T; Mielczarski J
    Rev Sci Instrum; 2008 Sep; 79(9):094101. PubMed ID: 19044432
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Optical readout method for microcantilever array sensing and its sensitivity analysis.
    Miao Z; Zhang Q; Guo Z; Wu X; Chen D
    Opt Lett; 2007 Mar; 32(6):594-6. PubMed ID: 17308571
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Design and experimental study of microcantilever ultrasonic detection transducers.
    Chen X; Stratoudaki T; Sharples SD; Clark M
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Dec; 56(12):2722-32. PubMed ID: 20040409
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Simultaneous readout of multiple microcantilever arrays with phase-shifting interferometric microscopy.
    Kelling S; Paoloni F; Huang J; Ostanin VP; Elliott SR
    Rev Sci Instrum; 2009 Sep; 80(9):093101. PubMed ID: 19791926
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Non-coplanar misalignment optical waveguide cantilever sensor with a monotonic response in a large operation range.
    Zhang H; Dai X; Hu Y; Wu D; Jing G; Li Y; Fan G
    Appl Opt; 2022 Dec; 61(35):10446-10450. PubMed ID: 36607104
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Detection of Trimethylamine Based on a Manganese Tetraphenylporphyrin Optical Waveguide Sensing Element.
    Wang J; Nizamidin P; Zhang Y; Kari N; Yimit A
    Anal Sci; 2018; 34(5):559-565. PubMed ID: 29743427
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fabrication, characterization, and simulation of a cantilever-based airflow sensor integrated with optical fiber.
    Cheri MS; Latifi H; Aghbolagh FB; Naeini OR; Taghavi M; Ghaderi M
    Appl Opt; 2013 May; 52(14):3420-7. PubMed ID: 23669859
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.