142 related articles for article (PubMed ID: 21815365)
1. Lateral dose profile characterization in scanning particle therapy.
Bäumer C; Farr JB
Med Phys; 2011 Jun; 38(6):2904-13. PubMed ID: 21815365
[TBL] [Abstract][Full Text] [Related]
2. Effects of spot parameters in pencil beam scanning treatment planning.
Kraan AC; Depauw N; Clasie B; Giunta M; Madden T; Kooy HM
Med Phys; 2018 Jan; 45(1):60-73. PubMed ID: 29148575
[TBL] [Abstract][Full Text] [Related]
3. Implication of spot position error on plan quality and patient safety in pencil-beam-scanning proton therapy.
Yu J; Beltran CJ; Herman MG
Med Phys; 2014 Aug; 41(8):081706. PubMed ID: 25086516
[TBL] [Abstract][Full Text] [Related]
4. Optimization of proton pencil beam positioning in collimated fields.
Behrends C; Bäumer C; Verbeek NG; Wulff J; Timmermann B
Med Phys; 2023 Apr; 50(4):2540-2551. PubMed ID: 36609847
[TBL] [Abstract][Full Text] [Related]
5. Is there a single spot size and grid for intensity modulated proton therapy? Simulation of head and neck, prostate and mesothelioma cases.
Widesott L; Lomax AJ; Schwarz M
Med Phys; 2012 Mar; 39(3):1298-308. PubMed ID: 22380362
[TBL] [Abstract][Full Text] [Related]
6. Simultaneous beam geometry and intensity map optimization in intensity-modulated radiation therapy.
Lee EK; Fox T; Crocker I
Int J Radiat Oncol Biol Phys; 2006 Jan; 64(1):301-20. PubMed ID: 16289912
[TBL] [Abstract][Full Text] [Related]
7. A fourier analysis on the maximum acceptable grid size for discrete proton beam dose calculation.
Li HS; Romeijn HE; Dempsey JF
Med Phys; 2006 Sep; 33(9):3508-18. PubMed ID: 17022247
[TBL] [Abstract][Full Text] [Related]
8. Impact of spot size variations on dose in scanned proton beam therapy.
Kraan AC; Depauw N; Clasie B; Madden T; Kooy HM
Phys Med; 2019 Jan; 57():58-64. PubMed ID: 30738532
[TBL] [Abstract][Full Text] [Related]
9. Assessing a set of optimal user interface parameters for intensity-modulated proton therapy planning.
Hillbrand M; Georg D
J Appl Clin Med Phys; 2010 Aug; 11(4):3219. PubMed ID: 21081877
[TBL] [Abstract][Full Text] [Related]
10. Measurements of lateral penumbra for uniform scanning proton beams under various beam delivery conditions and comparison to the XiO treatment planning system.
Rana S; Zeidan O; Ramirez E; Rains M; Gao J; Zheng Y
Med Phys; 2013 Sep; 40(9):091708. PubMed ID: 24007141
[TBL] [Abstract][Full Text] [Related]
11. Evaluation of the influence of double and triple Gaussian proton kernel models on accuracy of dose calculations for spot scanning technique.
Hirayama S; Takayanagi T; Fujii Y; Fujimoto R; Fujitaka S; Umezawa M; Nagamine Y; Hosaka M; Yasui K; Omachi C; Toshito T
Med Phys; 2016 Mar; 43(3):1437-50. PubMed ID: 26936728
[TBL] [Abstract][Full Text] [Related]
12. Design of a fast multileaf collimator for radiobiological optimized IMRT with scanned beams of photons, electrons, and light ions.
Svensson R; Larsson S; Gudowska I; Holmberg R; Brahme A
Med Phys; 2007 Mar; 34(3):877-88. PubMed ID: 17441233
[TBL] [Abstract][Full Text] [Related]
13. Dosimetric consequences of pencil beam width variations in scanned beam particle therapy.
Chanrion MA; Ammazzalorso F; Wittig A; Engenhart-Cabillic R; Jelen U
Phys Med Biol; 2013 Jun; 58(12):3979-93. PubMed ID: 23685746
[TBL] [Abstract][Full Text] [Related]
14. A dynamic collimation system for penumbra reduction in spot-scanning proton therapy: proof of concept.
Hyer DE; Hill PM; Wang D; Smith BR; Flynn RT
Med Phys; 2014 Sep; 41(9):091701. PubMed ID: 25186376
[TBL] [Abstract][Full Text] [Related]
15. Uncertainty reduction in intensity modulated proton therapy by inverse Monte Carlo treatment planning.
Morávek Z; Rickhey M; Hartmann M; Bogner L
Phys Med Biol; 2009 Aug; 54(15):4803-19. PubMed ID: 19622848
[TBL] [Abstract][Full Text] [Related]
16. Effects of spot size and spot spacing on lateral penumbra reduction when using a dynamic collimation system for spot scanning proton therapy.
Hyer DE; Hill PM; Wang D; Smith BR; Flynn RT
Phys Med Biol; 2014 Nov; 59(22):N187-96. PubMed ID: 25330783
[TBL] [Abstract][Full Text] [Related]
17. Accuracy assessment of the CNAO dose delivery system in the initial period of clinical activity and impact of later improvements on delivered dose distributions.
Vignati A; Hosseini SMA; Attili A; Ciocca M; Donetti M; Giordanengo S; Marchetto F; Mas Milian F; Russo G; Cirio R; Monaco V; Sacchi R
Med Phys; 2020 Apr; 47(4):1468-1480. PubMed ID: 31971612
[TBL] [Abstract][Full Text] [Related]
18. Variations in proton scanned beam dose delivery due to uncertainties in magnetic beam steering.
Peterson S; Polf J; Ciangaru G; Frank SJ; Bues M; Smith A
Med Phys; 2009 Aug; 36(8):3693-702. PubMed ID: 19746802
[TBL] [Abstract][Full Text] [Related]
19. Comparison of two methods for minimizing the effect of delayed charge on the dose delivered with a synchrotron based discrete spot scanning proton beam.
Whitaker TJ; Beltran C; Tryggestad E; Bues M; Kruse JJ; Remmes NB; Tasson A; Herman MG
Med Phys; 2014 Aug; 41(8):081703. PubMed ID: 25086513
[TBL] [Abstract][Full Text] [Related]
20. Comparison between the lateral penumbra of a collimated double-scattered beam and uncollimated scanning beam in proton radiotherapy.
Safai S; Bortfeld T; Engelsman M
Phys Med Biol; 2008 Mar; 53(6):1729-50. PubMed ID: 18367800
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]