These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 21815377)

  • 1. The importance of tissue segmentation for dose calculations for kilovoltage radiation therapy.
    Bazalova M; Graves EE
    Med Phys; 2011 Jun; 38(6):3039-49. PubMed ID: 21815377
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Kilovoltage beam Monte Carlo dose calculations in submillimeter voxels for small animal radiotherapy.
    Bazalova M; Zhou H; Keall PJ; Graves EE
    Med Phys; 2009 Nov; 36(11):4991-9. PubMed ID: 19994508
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Feasibility of external beam radiation therapy to deep-seated targets with kilovoltage x-rays.
    Bazalova-Carter M; Weil MD; Breitkreutz DY; Wilfley BP; Graves EE
    Med Phys; 2017 Feb; 44(2):597-607. PubMed ID: 28133751
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Bone and mucosal dosimetry in skin radiation therapy: a Monte Carlo study using kilovoltage photon and megavoltage electron beams.
    Chow JC; Jiang R
    Phys Med Biol; 2012 Jun; 57(12):3885-99. PubMed ID: 22642985
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A new tissue segmentation method to calculate 3D dose in small animal radiation therapy.
    Noblet C; Delpon G; Supiot S; Potiron V; Paris F; Chiavassa S
    Radiat Oncol; 2018 Feb; 13(1):32. PubMed ID: 29482652
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Monte Carlo calculation of imaging doses from diagnostic multidetector CT and kilovoltage cone-beam CT as part of prostate cancer treatment plans.
    Ding A; Gu J; Trofimov AV; Xu XG
    Med Phys; 2010 Dec; 37(12):6199-204. PubMed ID: 21302776
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dual-energy CT-based material extraction for tissue segmentation in Monte Carlo dose calculations.
    Bazalova M; Carrier JF; Beaulieu L; Verhaegen F
    Phys Med Biol; 2008 May; 53(9):2439-56. PubMed ID: 18421124
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An algorithm for kilovoltage x-ray dose calculations with applications in kV-CBCT scans and 2D planar projected radiographs.
    Pawlowski JM; Ding GX
    Phys Med Biol; 2014 Apr; 59(8):2041-58. PubMed ID: 24694756
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monte Carlo and
    Lawless MJ; Dimaso L; Palmer B; Micka J; Culberson WS; DeWerd LA
    Med Phys; 2018 Dec; 45(12):5564-5576. PubMed ID: 30273996
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Monte Carlo dosimetry modeling of focused kV x-ray radiotherapy of eye diseases with potential nanoparticle dose enhancement.
    Yan H; Ma X; Sun W; Mendez S; Stryker S; Starr-Baier S; Delliturri G; Zhu D; Nath R; Chen Z; Roberts K; MacDonald CA; Liu W
    Med Phys; 2018 Oct; 45(10):4720-4733. PubMed ID: 30133705
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Investigation of a synthetic diamond detector response in kilovoltage photon beams.
    Kaveckyte V; Persson L; Malusek A; Benmakhlouf H; Alm Carlsson G; Carlsson Tedgren Å
    Med Phys; 2020 Mar; 47(3):1268-1279. PubMed ID: 31880809
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Measured and Monte Carlo simulated surface dose reduction for superficial X-rays incident on tissue with underlying air or bone.
    Baines J; Zawlodzka S; Markwell T; Chan M
    Med Phys; 2018 Feb; 45(2):926-933. PubMed ID: 29235131
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Beam characteristics and radiation output of a kilovoltage cone-beam CT.
    Ding GX; Coffey CW
    Phys Med Biol; 2010 Sep; 55(17):5231-48. PubMed ID: 20714042
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The impact of dual energy CT imaging on dose calculations for pre-clinical studies.
    Vaniqui A; Schyns LEJR; Almeida IP; van der Heyden B; van Hoof SJ; Verhaegen F
    Radiat Oncol; 2017 Nov; 12(1):181. PubMed ID: 29157265
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Monte Carlo simulations of a kilovoltage external beam radiotherapy system on phantoms and breast patients.
    Breitkreutz DY; Weil MD; Zavgorodni S; Bazalova-Carter M
    Med Phys; 2017 Dec; 44(12):6548-6559. PubMed ID: 28986987
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Modality comparison for small animal radiotherapy: a simulation study.
    Bazalova M; Nelson G; Noll JM; Graves EE
    Med Phys; 2014 Jan; 41(1):011710. PubMed ID: 24387502
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Treatment planning for radiotherapy with very high-energy electron beams and comparison of VHEE and VMAT plans.
    Bazalova-Carter M; Qu B; Palma B; Hårdemark B; Hynning E; Jensen C; Maxim PG; Loo BW
    Med Phys; 2015 May; 42(5):2615-25. PubMed ID: 25979053
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accurate patient dosimetry of kilovoltage cone-beam CT in radiation therapy.
    Ding GX; Duggan DM; Coffey CW
    Med Phys; 2008 Mar; 35(3):1135-44. PubMed ID: 18404948
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An investigation of dose changes for therapeutic kilovoltage X-ray beams with underlying lead shielding.
    Hill R; Healy B; Holloway L; Baldock C
    Med Phys; 2007 Jul; 34(7):3045-53. PubMed ID: 17822012
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Commissioning kilovoltage cone-beam CT beams in a radiation therapy treatment planning system.
    Alaei P; Spezi E
    J Appl Clin Med Phys; 2012 Nov; 13(6):3971. PubMed ID: 23149789
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.