127 related articles for article (PubMed ID: 21824928)
1. Incomplete endothelialization and late dislocation after implantation of an Amplatzer septal occluder device.
Chen F; Zhao X; Zheng X; Chen S; Xu R; Qin Y
Circulation; 2011 Aug; 124(6):e188-9. PubMed ID: 21824928
[No Abstract] [Full Text] [Related]
2. Very Late Dislocation of an AMPLATZER Septal Occluder Device Suspected Thanks to a Recent Onset of Right-Axis Deviation.
Dendramis G; Paleologo C; Piraino D; Augugliaro S
JACC Cardiovasc Interv; 2016 Apr; 9(8):859-860. PubMed ID: 27101912
[No Abstract] [Full Text] [Related]
3. Percutaneous retrieval of an Amplatzer septal occluder device that had migrated to the aortic arch.
Guimaraes M; Denton CE; Uflacker R; Schonholz C; Selby B; Hannegan C
Cardiovasc Intervent Radiol; 2012 Apr; 35(2):430-3. PubMed ID: 21431972
[No Abstract] [Full Text] [Related]
4. Surgical rescue of embolized amplatzer septal occluder.
Cianciulli TF; Redruello HJ; Rubio MA; Poveda Camargo RL; Granja MA; Barrero CM; Mauro VM
Can J Cardiol; 2014 Apr; 30(4):465.e3-4. PubMed ID: 24518660
[No Abstract] [Full Text] [Related]
5. Migration of an AMPLATZER atrial septal occluder to the abdominal aorta.
Ferrero E; Ferri M; Viazzo A; Beqaraj F; Gibello L; Berardi G; Santovito D; Nessi F
Am J Cardiol; 2013 Aug; 112(4):612-3. PubMed ID: 23672986
[TBL] [Abstract][Full Text] [Related]
6. Left-sided migration of Sideris button atrial septal occluder device.
Jerath A; Jaura A; Karski J; Feindel C; Butany J; Vegas A
Eur J Echocardiogr; 2010 Jun; 11(5):E21. PubMed ID: 20097746
[TBL] [Abstract][Full Text] [Related]
7. Percutaneous retrieval of a dislodged Amplatzer septal occluder device from the pulmonary artery with sole use of a snare and device lassoing.
Manolis AS
Hellenic J Cardiol; 2018; 59(1):57-59. PubMed ID: 28818637
[No Abstract] [Full Text] [Related]
8. Amplatzer® septal occluder device early embolization to left ventricular outflow tract in asymptomatic patient.
Vizzari G; Pizzino F; Bajwa T; Ammar KA; Khandheria BK
Eur Heart J Cardiovasc Imaging; 2014 Aug; 15(8):925. PubMed ID: 24682957
[No Abstract] [Full Text] [Related]
9. [Migration to the left cavities of an interatrial communication closure device].
Gastaca Abásolo M; Batllori Gastón M; Castañeda Pascual M; Sáez Fernández A
Rev Esp Anestesiol Reanim; 2012 Oct; 59(8):462-4. PubMed ID: 22673186
[No Abstract] [Full Text] [Related]
10. Embolized Amplatzer septal occluder device presenting with ventricular fibrillation.
Yuce M; Ozer O; Cakici M; Cine N; Sari I; Davutoglu V
Cardiovasc Revasc Med; 2011; 12(2):131-2. PubMed ID: 21421193
[TBL] [Abstract][Full Text] [Related]
11. Dislocation of an Amplatzer device occluder 12 years following transcatheter insertion for a perimembranous ventricular septal defect.
Song L; An Q
J Card Surg; 2018 Dec; 33(12):867-869. PubMed ID: 30548083
[No Abstract] [Full Text] [Related]
12. Atrial septal defect occluder dislocation engaged through the tricuspid valve: surgical removal via right thoracotomy.
Cottini M; Pergolini A; Musumeci F
Kardiol Pol; 2017; 75(3):279. PubMed ID: 28326527
[No Abstract] [Full Text] [Related]
13. Late erosion of an Amplatzer septal occluder device 6 years after placement.
Taggart NW; Dearani JA; Hagler DJ
J Thorac Cardiovasc Surg; 2011 Jul; 142(1):221-2. PubMed ID: 21463878
[No Abstract] [Full Text] [Related]
14. Retrieval of embolized Amplatzer septal occluder using ablation catheter and triple-loop snare.
Kawamura A; Nishiyama N; Kawakami T; Fukuda K
Cardiovasc Interv Ther; 2014 Oct; 29(4):350-3. PubMed ID: 24415520
[TBL] [Abstract][Full Text] [Related]
15. Early migration of an Amplatzer muscular ventricular septal defect occluder device causing severe tricuspid valve obstruction.
Panduranga P; Al-Farqani A; Al-Maskari S
J Cardiovasc Med (Hagerstown); 2012 May; 13(5):336-7. PubMed ID: 22089813
[TBL] [Abstract][Full Text] [Related]
16. Asymptomatic embolized HELEX PFO closure device: catheter based retrieval and value of routine echocardiography the following day.
Moukarbel GV; Kitkungvan D; Safiia MA; Aragam J; Kinlay S
Int J Cardiol; 2012 Jul; 158(3):e57-9. PubMed ID: 22104997
[No Abstract] [Full Text] [Related]
17. Silent early migration of a Figulla® septal occluder into the left ventricle.
Gutiérrez-Barrios A; Lacal-Peña JM; Vignau-Cano JM; Bermudez-García A; Oneto-Otero J
Kardiol Pol; 2017; 75(7):724. PubMed ID: 28703271
[No Abstract] [Full Text] [Related]
18. Early Dislodgment and Migration of a Left Atrial Appendage Closure Device.
Sanhoury M; Fassini G; Dello Russo A; Lumia G; Bartorelli A
Am J Cardiol; 2017 Nov; 120(10):1905-1907. PubMed ID: 28917494
[TBL] [Abstract][Full Text] [Related]
19. Migration of Amplatzer Septal Occluder to the Deep Aortic Arch in a Patient With Multiple Anatomic Anomalies.
Saito T; Düsterhöft V; Hetzer R
Ann Thorac Surg; 2015 Jul; 100(1):318-20. PubMed ID: 26140780
[TBL] [Abstract][Full Text] [Related]
20. Percutaneous retrieval of embolized Amplatzer septal occluder from pulmonary artery using a novel method.
Candan Ö; Şahin M; Türkmen M
Turk Kardiyol Dern Ars; 2018 Sep; 46(6):501-503. PubMed ID: 30204142
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]