These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

173 related articles for article (PubMed ID: 21827003)

  • 1. [Non-invasive assessment of renal oxygenation with BOLD MRI in patients with type 2 diabetes].
    Yin WJ; Wang MS; Yang L; Liu RB
    Sichuan Da Xue Xue Bao Yi Xue Ban; 2011 May; 42(3):378-81, 426. PubMed ID: 21827003
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Non-invasive monitoring of renal oxygenation using BOLD-MRI: a reproducibility study.
    Simon-Zoula SC; Hofmann L; Giger A; Vogt B; Vock P; Frey FJ; Boesch C
    NMR Biomed; 2006 Feb; 19(1):84-9. PubMed ID: 16411163
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Noninvasive evaluation of renal oxygenation in diabetic nephropathy by BOLD-MRI.
    Yin WJ; Liu F; Li XM; Yang L; Zhao S; Huang ZX; Huang YQ; Liu RB
    Eur J Radiol; 2012 Jul; 81(7):1426-31. PubMed ID: 21470811
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A preliminary study of blood-oxygen-level-dependent MRI in patients with chronic kidney disease.
    Xin-Long P; Jing-Xia X; Jian-Yu L; Song W; Xin-Kui T
    Magn Reson Imaging; 2012 Apr; 30(3):330-5. PubMed ID: 22244540
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Blockade of the renin-angiotensin system and renal tissue oxygenation as measured with BOLD-MRI in patients with type 2 diabetes.
    Pruijm M; Hofmann L; Zanchi A; Maillard M; Forni V; Muller ME; Wuerzner G; Vogt B; Stuber M; Burnier M
    Diabetes Res Clin Pract; 2013 Feb; 99(2):136-44. PubMed ID: 23245807
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of intrarenal oxygenation by blood oxygen level-dependent magnetic resonance imaging in living kidney donors and their recipients: preliminary results.
    Malvezzi P; Bricault I; Terrier N; Bayle F
    Transplant Proc; 2009 Mar; 41(2):641-4. PubMed ID: 19328943
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The significance of BOLD MRI in differentiation between renal transplant rejection and acute tubular necrosis.
    Han F; Xiao W; Xu Y; Wu J; Wang Q; Wang H; Zhang M; Chen J
    Nephrol Dial Transplant; 2008 Aug; 23(8):2666-72. PubMed ID: 18308769
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of dark chocolate on renal tissue oxygenation as measured by BOLD-MRI in healthy volunteers.
    Pruijm M; Hofmann L; Charollais-Thoenig J; Forni V; Maillard M; Coristine A; Stuber M; Burnier M; Vogt B
    Clin Nephrol; 2013 Sep; 80(3):211-7. PubMed ID: 23557792
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Renal oxygenation changes during acute unilateral ureteral obstruction: assessment with blood oxygen level-dependent mr imaging--initial experience.
    Thoeny HC; Kessler TM; Simon-Zoula S; De Keyzer F; Mohaupt M; Studer UE; Vermathen P
    Radiology; 2008 Jun; 247(3):754-61. PubMed ID: 18403623
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of nitric oxide synthase inhibition on intrarenal oxygenation as evaluated by blood oxygenation level-dependent magnetic resonance imaging.
    Li LP; Ji L; Santos E; Dunkle E; Pierchala L; Prasad P
    Invest Radiol; 2009 Feb; 44(2):67-73. PubMed ID: 19034027
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Magnetic resonance imaging retinal oximetry: a quantitative physiological biomarker for early diabetic retinopathy?
    Yang Y; Zhu XR; Xu QG; Metcalfe H; Wang ZC; Yang JK
    Diabet Med; 2012 Apr; 29(4):501-5. PubMed ID: 21913965
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Three-year follow-up of human transplanted kidneys by diffusion-weighted MRI and blood oxygenation level-dependent imaging.
    Vermathen P; Binser T; Boesch C; Eisenberger U; Thoeny HC
    J Magn Reson Imaging; 2012 May; 35(5):1133-8. PubMed ID: 22180302
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of iodinated contrast agents on renal oxygenation level determined by blood oxygenation level dependent magnetic resonance imaging in rabbit models of type 1 and type 2 diabetic nephropathy.
    Wang JH; Ren K; Sun WG; Zhao L; Zhong HS; Xu K
    BMC Nephrol; 2014 Sep; 15():140. PubMed ID: 25182068
    [TBL] [Abstract][Full Text] [Related]  

  • 14. BOLD imaging: a potential predictive biomarker of renal functional outcome following revascularization in atheromatous renovascular disease.
    Chrysochou C; Mendichovszky IA; Buckley DL; Cheung CM; Jackson A; Kalra PA
    Nephrol Dial Transplant; 2012 Mar; 27(3):1013-9. PubMed ID: 21856759
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of Renal Blood Flow and Oxygenation in CKD Using Magnetic Resonance Imaging.
    Khatir DS; Pedersen M; Jespersen B; Buus NH
    Am J Kidney Dis; 2015 Sep; 66(3):402-11. PubMed ID: 25618188
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Kidney oxygenation during water diuresis and endothelial function in patients with type 2 diabetes and subjects at risk to develop diabetes.
    Economides PA; Caselli A; Zuo CS; Sparks C; Khaodhiar L; Katsilambros N; Horton ES; Veves A
    Metabolism; 2004 Feb; 53(2):222-7. PubMed ID: 14767875
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Renal lipids and oxygenation in diabetic mice: noninvasive quantification with MR imaging.
    Peng XG; Bai YY; Fang F; Wang XY; Mao H; Teng GJ; Ju S
    Radiology; 2013 Dec; 269(3):748-57. PubMed ID: 23901127
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of intra-renal oxygenation by BOLD MRI.
    Prasad PV
    Nephron Clin Pract; 2006; 103(2):c58-65. PubMed ID: 16543757
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Validation of quantitative BOLD MRI measurements in kidney: application to unilateral ureteral obstruction.
    Pedersen M; Dissing TH; Mørkenborg J; Stødkilde-Jørgensen H; Hansen LH; Pedersen LB; Grenier N; Frøkiaer J
    Kidney Int; 2005 Jun; 67(6):2305-12. PubMed ID: 15882272
    [TBL] [Abstract][Full Text] [Related]  

  • 20. BOLD quantified renal pO2 is sensitive to pharmacological challenges in rats.
    Thacker J; Zhang JL; Franklin T; Prasad P
    Magn Reson Med; 2017 Jul; 78(1):297-302. PubMed ID: 27501515
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.