320 related articles for article (PubMed ID: 21834005)
1. A radiofrequency coil to facilitate B₁⁺ shimming and parallel imaging acceleration in three dimensions at 7 T.
Gilbert KM; Curtis AT; Gati JS; Klassen LM; Menon RS
NMR Biomed; 2011 Aug; 24(7):815-23. PubMed ID: 21834005
[TBL] [Abstract][Full Text] [Related]
2. Transmit/receive radiofrequency coil with individually shielded elements.
Gilbert KM; Curtis AT; Gati JS; Klassen LM; Villemaire LE; Menon RS
Magn Reson Med; 2010 Dec; 64(6):1640-51. PubMed ID: 20648678
[TBL] [Abstract][Full Text] [Related]
3. Transceive surface coil array for magnetic resonance imaging of the human brain at 4 T.
Pinkerton RG; Barberi EA; Menon RS
Magn Reson Med; 2005 Aug; 54(2):499-503. PubMed ID: 16032690
[TBL] [Abstract][Full Text] [Related]
4. T1-weighted brain imaging with a 32-channel coil at 3T using TurboFLASH BLADE compared with standard cartesian k-space sampling.
Attenberger UI; Runge VM; Williams KD; Stemmer A; Michaely HJ; Schoenberg SO; Reiser MF; Wintersperger BJ
Invest Radiol; 2009 Mar; 44(3):177-83. PubMed ID: 19151605
[TBL] [Abstract][Full Text] [Related]
5. A conformal transceive array for 7 T neuroimaging.
Gilbert KM; Belliveau JG; Curtis AT; Gati JS; Klassen LM; Menon RS
Magn Reson Med; 2012 May; 67(5):1487-96. PubMed ID: 22190335
[TBL] [Abstract][Full Text] [Related]
6. An eight-channel phased array RF coil for spine MR imaging at 7 T.
Kraff O; Bitz AK; Kruszona S; Orzada S; Schaefer LC; Theysohn JM; Maderwald S; Ladd ME; Quick HH
Invest Radiol; 2009 Nov; 44(11):734-40. PubMed ID: 19809342
[TBL] [Abstract][Full Text] [Related]
7. Improvement of SNR and acquisition acceleration using a 32-channel head coil compared to a 12-channel head coil at 3T.
Reiss-Zimmermann M; Gutberlet M; Köstler H; Fritzsch D; Hoffmann KT
Acta Radiol; 2013 Jul; 54(6):702-8. PubMed ID: 23474767
[TBL] [Abstract][Full Text] [Related]
8. Parallel imaging with 3D TPI trajectory: SNR and acceleration benefits.
Qian Y; Stenger VA; Boada FE
Magn Reson Imaging; 2009 Jun; 27(5):656-63. PubMed ID: 19110392
[TBL] [Abstract][Full Text] [Related]
9. RF surface receive array coils: the art of an LC circuit.
Fujita H; Zheng T; Yang X; Finnerty MJ; Handa S
J Magn Reson Imaging; 2013 Jul; 38(1):12-25. PubMed ID: 23649497
[TBL] [Abstract][Full Text] [Related]
10. Design of a novel antisymmetric coil array for parallel transmit cardiac MRI in pigs at 7 T.
Elabyad IA; Terekhov M; Stefanescu MR; Lohr D; Fischer M; Schreiber LM
J Magn Reson; 2019 Aug; 305():195-208. PubMed ID: 31306985
[TBL] [Abstract][Full Text] [Related]
11. Signal-to-noise ratio and parallel imaging performance of a 16-channel receive-only brain coil array at 3.0 Tesla.
de Zwart JA; Ledden PJ; van Gelderen P; Bodurka J; Chu R; Duyn JH
Magn Reson Med; 2004 Jan; 51(1):22-6. PubMed ID: 14705041
[TBL] [Abstract][Full Text] [Related]
12. Diffusion-weighted imaging in patients with acute brain ischemia at 3 T: current possibilities and future perspectives comparing conventional echoplanar diffusion-weighted imaging and fast spin echo diffusion-weighted imaging sequences using BLADE (PROPELLER).
Fries P; Runge VM; Kirchin MA; Stemmer A; Naul LG; Wiliams KD; Reith W; Bücker A; Schneider G
Invest Radiol; 2009 Jun; 44(6):351-9. PubMed ID: 19363447
[TBL] [Abstract][Full Text] [Related]
13. Optimized parallel transmit and receive radiofrequency coil for ultrahigh-field MRI of monkeys.
Gilbert KM; Gati JS; Barker K; Everling S; Menon RS
Neuroimage; 2016 Jan; 125():153-161. PubMed ID: 26497267
[TBL] [Abstract][Full Text] [Related]
14. A 32-channel combined RF and B0 shim array for 3T brain imaging.
Stockmann JP; Witzel T; Keil B; Polimeni JR; Mareyam A; LaPierre C; Setsompop K; Wald LL
Magn Reson Med; 2016 Jan; 75(1):441-51. PubMed ID: 25689977
[TBL] [Abstract][Full Text] [Related]
15. Design and application of combined 8-channel transmit and 10-channel receive arrays and radiofrequency shimming for 7-T shoulder magnetic resonance imaging.
Brown R; Deniz CM; Zhang B; Chang G; Sodickson DK; Wiggins GC
Invest Radiol; 2014 Jan; 49(1):35-47. PubMed ID: 24056112
[TBL] [Abstract][Full Text] [Related]
16. A volume microstrip RF coil for MRI microscopy.
Jasiński K; Młynarczyk A; Latta P; Volotovskyy V; Węglarz WP; Tomanek B
Magn Reson Imaging; 2012 Jan; 30(1):70-7. PubMed ID: 22055746
[TBL] [Abstract][Full Text] [Related]
17. [A new approach to research graphical performance of MRI RF coil based on the quantitative comparison method].
Zhu G; Li B; Wei X
Zhongguo Yi Liao Qi Xie Za Zhi; 2010 May; 34(3):180-2. PubMed ID: 20812640
[TBL] [Abstract][Full Text] [Related]
18. Parallel-transmission-enabled magnetization-prepared rapid gradient-echo T1-weighted imaging of the human brain at 7 T.
Cloos MA; Boulant N; Luong M; Ferrand G; Giacomini E; Hang MF; Wiggins CJ; Le Bihan D; Amadon A
Neuroimage; 2012 Sep; 62(3):2140-50. PubMed ID: 22659484
[TBL] [Abstract][Full Text] [Related]
19. Transmit and receive RF fields determination from a single low-tip-angle gradient-echo scan by scaling of SVD data.
Sbrizzi A; Raaijmakers AJ; Hoogduin H; Lagendijk JJ; Luijten PR; van den Berg CA
Magn Reson Med; 2014 Jul; 72(1):248-59. PubMed ID: 24022840
[TBL] [Abstract][Full Text] [Related]
20. A human cerebral and cerebellar 8-channel transceive RF dipole coil array at 7T.
Clément JD; Gruetter R; Ipek Ö
Magn Reson Med; 2019 Feb; 81(2):1447-1458. PubMed ID: 30226637
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]