These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

77 related articles for article (PubMed ID: 21839067)

  • 21. Evaluation of the interference of hemoglobin, bilirubin, and lipids on Roche Cobas 6000 assays.
    Ji JZ; Meng QH
    Clin Chim Acta; 2011 Aug; 412(17-18):1550-3. PubMed ID: 21575617
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Plasma hemoglobin measurement techniques for the in vitro evaluation of blood damage caused by medical devices.
    Malinauskas RA
    Artif Organs; 1997 Dec; 21(12):1255-67. PubMed ID: 9423977
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Reliability of hemoglobin measurement by HemoCue in patients with gastrointestinal bleeding].
    Gómez-Escolar Viejo L; Sala GS; Azorin JM; Laudemia R; Sánchez J; Regadera MP
    Gastroenterol Hepatol; 2009 May; 32(5):334-8. PubMed ID: 19457588
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Real-time PCR microfluidic devices with concurrent electrochemical detection.
    Fang TH; Ramalingam N; Xian-Dui D; Ngin TS; Xianting Z; Lai Kuan AT; Peng Huat EY; Hai-Qing G
    Biosens Bioelectron; 2009 Mar; 24(7):2131-6. PubMed ID: 19162460
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Verification of performance with the automated direct optical TIRF immunosensor (River Analyser) in single and multi-analyte assays with real water samples.
    Tschmelak J; Proll G; Gauglitz G
    Biosens Bioelectron; 2004 Nov; 20(4):743-52. PubMed ID: 15522589
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Electrochemical biosensor technology: application to pesticide detection.
    Palchetti I; Laschi S; Mascini M
    Methods Mol Biol; 2009; 504():115-26. PubMed ID: 19159094
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Bioelectrochemistry of hemoglobin immobilized on a sodium alginate-multiwall carbon nanotubes composite film.
    Zhao HY; Zheng W; Meng ZX; Zhou HM; Xu XX; Li Z; Zheng YF
    Biosens Bioelectron; 2009 Apr; 24(8):2352-7. PubMed ID: 19135354
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Direct and rapid electrochemical biosensing of the human interleukin-2 DNA in unpurified polymerase chain reaction (PCR)-amplified real samples.
    Pournaghi-Azar MH; Alipour E; Zununi S; Froohandeh H; Hejazi MS
    Biosens Bioelectron; 2008 Dec; 24(4):524-30. PubMed ID: 18617384
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The effect of hemolysis on creatine kinase determination.
    Greenson JK; Farber SJ; Dubin SB
    Arch Pathol Lab Med; 1989 Feb; 113(2):184-5. PubMed ID: 2916906
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Study of forensic and clinical source hemoglobin interference with the duPont aca ethanol method.
    Gadsden RH
    Ann Clin Lab Sci; 1986; 16(5):399-406. PubMed ID: 3777857
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Stability of hematological analytes depends on the hematology analyser used: a stability study with Bayer Advia 120, Beckman Coulter LH 750 and Sysmex XE 2100.
    Imeri F; Herklotz R; Risch L; Arbetsleitner C; Zerlauth M; Risch GM; Huber AR
    Clin Chim Acta; 2008 Nov; 397(1-2):68-71. PubMed ID: 18706900
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Comparison of HemoCue with cyanmethemoglobin method for estimating hemoglobin].
    Zhao X; Yin SA
    Wei Sheng Yan Jiu; 2003 Sep; 32(5):495-7. PubMed ID: 14650200
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A novel nitromethane biosensor based on biocompatible conductive redox graphene-chitosan/hemoglobin/graphene/room temperature ionic liquid matrix.
    Wang L; Zhang X; Xiong H; Wang S
    Biosens Bioelectron; 2010 Nov; 26(3):991-5. PubMed ID: 20833016
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Attachment of gold nanoparticles to glassy carbon electrode and its application for the direct electrochemistry and electrocatalytic behavior of hemoglobin.
    Zhang L; Jiang X; Wang E; Dong S
    Biosens Bioelectron; 2005 Aug; 21(2):337-45. PubMed ID: 16023961
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparison of pesticide sensitivity by electrochemical test based on acetylcholinesterase biosensor.
    Du D; Huang X; Cai J; Zhang A
    Biosens Bioelectron; 2007 Sep; 23(2):285-9. PubMed ID: 17590326
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Interference and blood sample preparation for a pyruvate enzymatic assay.
    Chuang CK; Wang TJ; Yeung CY; Hsieh WS; Lin DS; Ho SC; Lin SP
    Clin Biochem; 2006 Jan; 39(1):74-7. PubMed ID: 16309664
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effects of a hemoglobin-based oxygen carrier (HBOC-201) on coagulation testing.
    Jahr JS; Lurie F; Gosselin R; Lin JS; Wong L; Larkin E
    Clin Lab Sci; 2000; 13(4):210-4. PubMed ID: 11586506
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Technical and clinical evaluation of a glucose meter employing amperometric biosensor technology.
    Demir S; Yilmazturk GC; Aslan D
    Diabetes Res Clin Pract; 2008 Mar; 79(3):400-4. PubMed ID: 18023908
    [TBL] [Abstract][Full Text] [Related]  

  • 39. New kinetic procedure for the measurement of conjugated bilirubin with a centrifugal analyzer.
    Valdes R; Brody JP; Savory J
    Ann Clin Lab Sci; 1979; 9(3):251-7. PubMed ID: 464545
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Effect of protein on hemoglobin and hematocrit assays with a conductivity-based point-of-care testing device: comparison with optical methods.
    Hopfer SM; Nadeau FL; Sundra M; Makowski GS
    Ann Clin Lab Sci; 2004; 34(1):75-82. PubMed ID: 15038671
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 4.