237 related articles for article (PubMed ID: 21839206)
1. Disposable luminol copolymer-based biosensor for uric acid in urine.
Ballesta-Claver J; Díaz Ortega IF; Valencia-Mirón MC; Capitán-Vallvey LF
Anal Chim Acta; 2011 Sep; 702(2):254-61. PubMed ID: 21839206
[TBL] [Abstract][Full Text] [Related]
2. SPE biosensor for cholesterol in serum samples based on electrochemiluminescent luminol copolymer.
Ballesta-Claver J; Salinas Velázquez P; Valencia-Mirón MC; Capitán-Vallvey LF
Talanta; 2011 Oct; 86():178-85. PubMed ID: 22063528
[TBL] [Abstract][Full Text] [Related]
3. Electrochemiluminescent disposable cholesterol biosensor based on avidin-biotin assembling with the electroformed luminescent conducting polymer poly(luminol-biotinylated pyrrole).
Ballesta-Claver J; Ametis-Cabello J; Morales-Sanfrutos J; Megía-Fernández A; Valencia-Mirón MC; Santoyo-González F; Capitán-Vallvey LF
Anal Chim Acta; 2012 Nov; 754():91-8. PubMed ID: 23140959
[TBL] [Abstract][Full Text] [Related]
4. Disposable electrochemiluminescent biosensor for lactate determination in saliva.
Ballesta Claver J; Valencia Mirón MC; Capitán-Vallvey LF
Analyst; 2009 Jul; 134(7):1423-32. PubMed ID: 19562211
[TBL] [Abstract][Full Text] [Related]
5. Disposable biosensor based on cathodic electrochemiluminescence of tris(2,2-bipyridine)ruthenium(II) for uric acid determination.
Ballesta-Claver J; Rodríguez-Gómez R; Capitán-Vallvey LF
Anal Chim Acta; 2013 Apr; 770():153-60. PubMed ID: 23498698
[TBL] [Abstract][Full Text] [Related]
6. A biosensor for cholesterol based on gold nanoparticles-catalyzed luminol electrogenerated chemiluminescence.
Zhang M; Yuan R; Chai Y; Chen S; Zhong H; Wang C; Cheng Y
Biosens Bioelectron; 2012 Feb; 32(1):288-92. PubMed ID: 22206786
[TBL] [Abstract][Full Text] [Related]
7. An amperometric uric acid biosensor based on multiwalled carbon nanotube-gold nanoparticle composite.
Chauhan N; Pundir CS
Anal Biochem; 2011 Jun; 413(2):97-103. PubMed ID: 21315682
[TBL] [Abstract][Full Text] [Related]
8. Development and analytical application of an uric acid biosensor using an uricase-immobilized eggshell membrane.
Zhang Y; Wen G; Zhou Y; Shuang S; Dong C; Choi MM
Biosens Bioelectron; 2007 Mar; 22(8):1791-7. PubMed ID: 17023154
[TBL] [Abstract][Full Text] [Related]
9. Biosensor based on chemiluminescence for serum uric acid determination.
Liu J; Guo J; Li G
Chin J Biotechnol; 1995; 11(3):177-83. PubMed ID: 8679934
[TBL] [Abstract][Full Text] [Related]
10. Preliminary investigations on a new disposable potentiometric biosensor for uric acid.
Liao CW; Chou JC; Sun TP; Hsiung SK; Hsieh JH
IEEE Trans Biomed Eng; 2006 Jul; 53(7):1401-8. PubMed ID: 16830944
[TBL] [Abstract][Full Text] [Related]
11. Biocompatible electrochemiluminescent biosensor for choline based on enzyme/titanate nanotubes/chitosan composite modified electrode.
Dai H; Chi Y; Wu X; Wang Y; Wei M; Chen G
Biosens Bioelectron; 2010 Feb; 25(6):1414-9. PubMed ID: 19945840
[TBL] [Abstract][Full Text] [Related]
12. An amperomertic uric acid biosensor based on immobilization of uricase onto polyaniline-multiwalled carbon nanotube composite film.
Bhambi M; Sumana G; Malhotra BD; Pundir CS
Artif Cells Blood Substit Immobil Biotechnol; 2010 Aug; 38(4):178-85. PubMed ID: 20367113
[TBL] [Abstract][Full Text] [Related]
13. Fabrication of dissolved O2 metric uric acid biosensor using uricase epoxy resin biocomposite membrane.
Arora J; Nandwani S; Bhambi M; Pundir CS
Anal Chim Acta; 2009 Aug; 647(2):195-201. PubMed ID: 19591705
[TBL] [Abstract][Full Text] [Related]
14. Low-potential detection of endogenous and physiological uric acid at uricase-thionine-single-walled carbon nanotube modified electrodes.
Chen D; Wang Q; Jin J; Wu P; Wang H; Yu S; Zhang H; Cai C
Anal Chem; 2010 Mar; 82(6):2448-55. PubMed ID: 20163156
[TBL] [Abstract][Full Text] [Related]
15. Sensitive determination of carbidopa through the electrochemiluminescence of luminol at graphene-modified electrodes.
Hosseini M; Mirzanasiri N; Rezapour M; Sheikhha MH; Faridbod F; Norouzi P; Ganjali MR
Luminescence; 2015 Jun; 30(4):376-81. PubMed ID: 25131492
[TBL] [Abstract][Full Text] [Related]
16. An amperometric uric acid biosensor based on chitosan-carbon nanotubes electrospun nanofiber on silver nanoparticles.
Numnuam A; Thavarungkul P; Kanatharana P
Anal Bioanal Chem; 2014 Jun; 406(15):3763-72. PubMed ID: 24718436
[TBL] [Abstract][Full Text] [Related]
17. Amperometric glucose biosensors based on layer-by-layer assembly of chitosan and glucose oxidase on the Prussian blue-modified gold electrode.
Yin B; Yuan R; Chai Y; Chen S; Cao S; Xu Y; Fu P
Biotechnol Lett; 2008 Feb; 30(2):317-22. PubMed ID: 17912595
[TBL] [Abstract][Full Text] [Related]
18. Electrochemiluminescent aptamer biosensor for the determination of ochratoxin A at a gold-nanoparticles-modified gold electrode using N-(aminobutyl)-N-ethylisoluminol as a luminescent label.
Wang Z; Duan N; Hun X; Wu S
Anal Bioanal Chem; 2010 Nov; 398(5):2125-32. PubMed ID: 20835816
[TBL] [Abstract][Full Text] [Related]
19. Uricase-adsorbed carbon-felt reactor coupled with a peroxidase-modified carbon-felt-based H2O2 detector for highly sensitive amperometric flow determination of uric acid.
Wang Y; Hasebe Y
J Pharm Biomed Anal; 2012 Jan; 57():125-32. PubMed ID: 21906900
[TBL] [Abstract][Full Text] [Related]
20. A novel reagentless amperometric immunosensor based on gold nanoparticles/TMB/Nafion-modified electrode.
Wu Y; Zheng J; Li Z; Zhao Y; Zhang Y
Biosens Bioelectron; 2009 Jan; 24(5):1389-93. PubMed ID: 18799302
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]