324 related articles for article (PubMed ID: 21843297)
1. Evaluation of hydraulic radial forces on the impeller by the volute in a centrifugal rotary blood pump.
Boehning F; Timms DL; Amaral F; Oliveira L; Graefe R; Hsu PL; Schmitz-Rode T; Steinseifer U
Artif Organs; 2011 Aug; 35(8):818-25. PubMed ID: 21843297
[TBL] [Abstract][Full Text] [Related]
2. Evaluation of left ventricular assist device performance and hydraulic force in a complete mock circulation loop.
Timms D; Hayne M; Tan A; Pearcy M
Artif Organs; 2005 Jul; 29(7):573-80. PubMed ID: 15982286
[TBL] [Abstract][Full Text] [Related]
3. Fluid force predictions and experimental measurements for a magnetically levitated pediatric ventricular assist device.
Throckmorton AL; Untaroiu A; Lim DS; Wood HG; Allaire PE
Artif Organs; 2007 May; 31(5):359-68. PubMed ID: 17470205
[TBL] [Abstract][Full Text] [Related]
4. Investigation of the influence of volute design on journal bearing bias force using computational fluid dynamics.
Graefe R; Timms D; Böhning F; Schmitz-Rode T; Steinseifer U
Artif Organs; 2010 Sep; 34(9):760-5. PubMed ID: 20883394
[TBL] [Abstract][Full Text] [Related]
5. Design considerations of volute geometry of a centrifugal blood pump.
Chan WK; Wong YW; Hu W
Artif Organs; 2005 Dec; 29(12):937-48. PubMed ID: 16305649
[TBL] [Abstract][Full Text] [Related]
6. Numerical and experimental analysis of an axial flow left ventricular assist device: the influence of the diffuser on overall pump performance.
Untaroiu A; Throckmorton AL; Patel SM; Wood HG; Allaire PE; Olsen DB
Artif Organs; 2005 Jul; 29(7):581-91. PubMed ID: 15982287
[TBL] [Abstract][Full Text] [Related]
7. Numerical study of a bio-centrifugal blood pump with straight impeller blade profiles.
Song G; Chua LP; Lim TM
Artif Organs; 2010 Feb; 34(2):98-104. PubMed ID: 19817732
[TBL] [Abstract][Full Text] [Related]
8. Magnetically suspended centrifugal blood pump with a self bearing motor.
Masuzawa T; Onuma H; Kim SJ; Okada Y
ASAIO J; 2002; 48(4):437-42. PubMed ID: 12141477
[TBL] [Abstract][Full Text] [Related]
9. Comparison of hydraulic and hemolytic properties of different impeller designs of an implantable rotary blood pump by computational fluid dynamics.
Arvand A; Hahn N; Hormes M; Akdis M; Martin M; Reul H
Artif Organs; 2004 Oct; 28(10):892-8. PubMed ID: 15384994
[TBL] [Abstract][Full Text] [Related]
10. Permanent magnetic-levitation of rotating impeller: a decisive breakthrough in the centrifugal pump.
Qian KX; Zeng P; Ru WM; Yuan HY; Feng ZG; Li L
J Med Eng Technol; 2002; 26(1):36-8. PubMed ID: 11924845
[TBL] [Abstract][Full Text] [Related]
11. Impeller behavior and displacement of the VentrAssist implantable rotary blood pump.
Chung MK; Zhang N; Tansley GD; Woodard JC
Artif Organs; 2004 Mar; 28(3):287-97. PubMed ID: 15046628
[TBL] [Abstract][Full Text] [Related]
12. Quantification of the secondary flow in a radial coupled centrifugal blood pump based on particle tracking velocimetry.
Watanabe N; Masuda T; Iida T; Kataoka H; Fujimoto T; Takatani S
Artif Organs; 2005 Jan; 29(1):26-35. PubMed ID: 15644080
[TBL] [Abstract][Full Text] [Related]
13. Dynamic characteristics of a magnetically levitated impeller in a centrifugal blood pump.
Asama J; Shinshi T; Hoshi H; Takatani S; Shimokohbe A
Artif Organs; 2007 Apr; 31(4):301-11. PubMed ID: 17437499
[TBL] [Abstract][Full Text] [Related]
14. Study of velocity and shear stress distributions in the impeller passages and the volute of a bio-centrifugal ventricular assist device.
Chua LP; Ong KS; Song G
Artif Organs; 2008 May; 32(5):376-87. PubMed ID: 18471167
[TBL] [Abstract][Full Text] [Related]
15. Flow analysis of the Cleveland Clinic centrifugal pump.
Veres JP; Golding LA; Smith WA; Horvath D; Medvedev A
ASAIO J; 1997; 43(5):M778-81. PubMed ID: 9360152
[TBL] [Abstract][Full Text] [Related]
16. Development of a prototype magnetically suspended rotor ventricular assist device.
Bearnson GB; Maslen EH; Olsen DB; Allaire PE; Khanwilkar PS; Long JW; Kim HC
ASAIO J; 1996; 42(4):275-81. PubMed ID: 8828784
[TBL] [Abstract][Full Text] [Related]
17. Computational fluid dynamics-based hydraulic and hemolytic analyses of a novel left ventricular assist blood pump.
Yang XC; Zhang Y; Gui XM; Hu SS
Artif Organs; 2011 Oct; 35(10):948-55. PubMed ID: 21517911
[TBL] [Abstract][Full Text] [Related]
18. Numerical study of a centrifugal blood pump with different impeller profiles.
Song G; Chua LP; Lim TM
ASAIO J; 2010; 56(1):24-9. PubMed ID: 20019595
[TBL] [Abstract][Full Text] [Related]
19. Fluid dynamic characteristics of monopivot magnetic suspension blood pumps.
Yamane T; Nishida M; Asztalos B; Tsutsui T; Jikuya T
ASAIO J; 1997; 43(5):M635-8. PubMed ID: 9360122
[TBL] [Abstract][Full Text] [Related]
20. In vivo evaluation of the "TinyPump" as a pediatric left ventricular assist device.
Kitao T; Ando Y; Yoshikawa M; Kobayashi M; Kimura T; Ohsawa H; Machida S; Yokoyama N; Sakota D; Konno T; Ishihara K; Takatani S
Artif Organs; 2011 May; 35(5):543-53. PubMed ID: 21595723
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]