BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

520 related articles for article (PubMed ID: 21846411)

  • 1. Comparison of ring artifact removal methods using flat panel detector based CT images.
    Anas EM; Kim JG; Lee SY; Hasan K
    Biomed Eng Online; 2011 Aug; 10():72. PubMed ID: 21846411
    [TBL] [Abstract][Full Text] [Related]  

  • 2. High-quality 3D correction of ring and radiant artifacts in flat panel detector-based cone beam volume CT imaging.
    Anas EM; Kim JG; Lee SY; Hasan MK
    Phys Med Biol; 2011 Oct; 56(19):6495-519. PubMed ID: 21934193
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A new iterative algorithm for ring artifact reduction in CT using ring total variation.
    Salehjahromi M; Wang Q; Zhang Y; Gjesteby LA; Harrison D; Wang G; Edic PM; Yu H
    Med Phys; 2019 Nov; 46(11):4803-4815. PubMed ID: 31408539
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Removal of ring artifacts in CT imaging through detection and correction of stripes in the sinogram.
    Abu Anas EM; Lee SY; Hasan MK
    Phys Med Biol; 2010 Nov; 55(22):6911-30. PubMed ID: 21048294
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [CT ring artifact reduction using an improved wavelet filtering in the sinogram domain].
    Guo H; Zeng D; Zhang H; Huang J; Zhang J; Ma J
    Nan Fang Yi Ke Da Xue Xue Bao; 2015 Aug; 35(9):1258-62. PubMed ID: 26403734
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Single-pass metal artifact reduction using a dual-layer flat panel detector.
    Shi L; Bennett NR; Shiroma A; Sun M; Zhang J; Colbeth R; Star-Lack J; Lu M; Wang AS
    Med Phys; 2021 Oct; 48(10):6482-6496. PubMed ID: 34374461
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cone beam volume CT image artifacts caused by defective cells in x-ray flat panel imagers and the artifact removal using a wavelet-analysis-based algorithm.
    Tang X; Ning R; Yu R; Conover D
    Med Phys; 2001 May; 28(5):812-25. PubMed ID: 11393477
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Iterative image-domain ring artifact removal in cone-beam CT.
    Liang X; Zhang Z; Niu T; Yu S; Wu S; Li Z; Zhang H; Xie Y
    Phys Med Biol; 2017 Jul; 62(13):5276-5292. PubMed ID: 28585520
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Deep learning based correction of low performing pixel in computed tomography.
    Patil BD; Singhal V; Agrawal U; Langoju R; Hsieh J; Lakshminarasimhan S; Das B
    Biomed Phys Eng Express; 2022 Aug; 8(5):. PubMed ID: 35939980
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Classification of ring artifacts for their effective removal using type adaptive correction schemes.
    Anas EM; Lee SY; Hasan K
    Comput Biol Med; 2011 Jun; 41(6):390-401. PubMed ID: 21513928
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A new dental CBCT metal artifact reduction method based on a dual-domain processing framework.
    Tang H; Lin YB; Jiang SD; Li Y; Li T; Bao XD
    Phys Med Biol; 2023 Aug; 68(17):. PubMed ID: 37524084
    [No Abstract]   [Full Text] [Related]  

  • 12. A Ring Artifact Correction Method: Validation by Micro-CT Imaging with Flat-Panel Detectors and a 2D Photon-Counting Detector.
    Eldib ME; Hegazy M; Mun YJ; Cho MH; Cho MH; Lee SY
    Sensors (Basel); 2017 Jan; 17(2):. PubMed ID: 28146088
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Artifact suppression for breast specimen imaging in micro CBCT using deep learning.
    Aootaphao S; Puttawibul P; Thajchayapong P; Thongvigitmanee SS
    BMC Med Imaging; 2024 Feb; 24(1):34. PubMed ID: 38321390
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Empirical scatter correction: CBCT scatter artifact reduction without prior information.
    Trapp P; Maier J; Susenburger M; Sawall S; Kachelrieß M
    Med Phys; 2022 Jul; 49(7):4566-4584. PubMed ID: 35390181
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Iterative Ring Artifact Removal Method for Helical Computed Tomography Scans.
    Balogh ZA; Huszar T; Kis BJ
    J Comput Assist Tomogr; 2020; 44(5):796-805. PubMed ID: 32932343
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of ring artifact correction methods for flat-detector CT.
    Prell D; Kyriakou Y; Kalender WA
    Phys Med Biol; 2009 Jun; 54(12):3881-95. PubMed ID: 19491452
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Metal Artifact Reduction in Cone-Beam Computed Tomography for Head and Neck Radiotherapy.
    Korpics M; Johnson P; Patel R; Surucu M; Choi M; Emami B; Roeske JC
    Technol Cancer Res Treat; 2016 Dec; 15(6):NP88-NP94. PubMed ID: 26614780
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Sinogram domain metal artifact correction of CT via deep learning.
    Zhu Y; Zhao H; Wang T; Deng L; Yang Y; Jiang Y; Li N; Chan Y; Dai J; Zhang C; Li Y; Xie Y; Liang X
    Comput Biol Med; 2023 Mar; 155():106710. PubMed ID: 36842222
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Reduction of ring artifacts in CBCT: detection and correction of pixel gain variations in flat panel detectors.
    Altunbas C; Lai CJ; Zhong Y; Shaw CC
    Med Phys; 2014 Sep; 41(9):091913. PubMed ID: 25186400
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An irregular metal trace inpainting network for x-ray CT metal artifact reduction.
    Peng C; Li B; Li M; Wang H; Zhao Z; Qiu B; Chen DZ
    Med Phys; 2020 Sep; 47(9):4087-4100. PubMed ID: 32463485
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 26.