These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
134 related articles for article (PubMed ID: 21852372)
1. A flow-diverting stent is not a pressure-diverting stent. Schneiders JJ; VanBavel E; Majoie CB; Ferns SP; van den Berg R AJNR Am J Neuroradiol; 2013 Jan; 34(1):E1-4. PubMed ID: 21852372 [TBL] [Abstract][Full Text] [Related]
2. Actual metal coverage at the neck is critical for flow-diverting stents in treating intracranial aneurysms. Wang K; Yuan S AJNR Am J Neuroradiol; 2013 Mar; 34(3):E31-2. PubMed ID: 23449658 [No Abstract] [Full Text] [Related]
3. Reply: To PMID 21852372. van den Berg R; Schneiders JJ; Ferns SP; Majoie CB AJNR Am J Neuroradiol; 2013 Mar; 34(3):E33. PubMed ID: 23610782 [No Abstract] [Full Text] [Related]
6. Aneurysm pressure measurement before and after placement of a Pipeline stent: feasibility study using a 0.014 inch pressure wire for coronary intervention. Tateshima S; Jones JG; Mayor Basto F; Vinuela F; Duckwiler GR J Neurointerv Surg; 2016 Jun; 8(6):603-7. PubMed ID: 24871764 [TBL] [Abstract][Full Text] [Related]
11. Prospective Study of Early MRI Appearances following Flow-Diverting Stent Placement for Intracranial Aneurysms. McGuinness BJ; Memon S; Hope JK AJNR Am J Neuroradiol; 2015 May; 36(5):943-8. PubMed ID: 25767184 [TBL] [Abstract][Full Text] [Related]
12. Ischemic Stroke After Treatment of Intraprocedural Thrombosis During Stent-Assisted Coiling and Flow Diversion. Adeeb N; Griessenauer CJ; Moore JM; Foreman PM; Shallwani H; Motiei-Langroudi R; Gupta R; Baccin CE; Alturki A; Harrigan MR; Siddiqui AH; Levy EI; Ogilvy CS; Thomas AJ Stroke; 2017 Apr; 48(4):1098-1100. PubMed ID: 28246277 [TBL] [Abstract][Full Text] [Related]
13. Aneurysm rupture following treatment with flow-diverting stents: computational hemodynamics analysis of treatment. Cebral JR; Mut F; Raschi M; Scrivano E; Ceratto R; Lylyk P; Putman CM AJNR Am J Neuroradiol; 2011 Jan; 32(1):27-33. PubMed ID: 21071533 [TBL] [Abstract][Full Text] [Related]
14. Evaluation of stent effect and thrombosis generation with different blood rheology on an intracranial aneurysm by the Lattice Boltzmann method. Mezali F; Benmamar S; Naima K; Ameur H; Rafik O Comput Methods Programs Biomed; 2022 Jun; 219():106757. PubMed ID: 35338884 [TBL] [Abstract][Full Text] [Related]
15. Hemodynamic alterations after stent implantation in 15 cases of intracranial aneurysm. Wang C; Tian Z; Liu J; Jing L; Paliwal N; Wang S; Zhang Y; Xiang J; Siddiqui AH; Meng H; Yang X Acta Neurochir (Wien); 2016 Apr; 158(4):811-819. PubMed ID: 26746828 [TBL] [Abstract][Full Text] [Related]
16. Intra-aneurysmal hemodynamic alterations by a self-expandable intracranial stent and flow diversion stent: high intra-aneurysmal pressure remains regardless of flow velocity reduction. Shobayashi Y; Tateshima S; Kakizaki R; Sudo R; Tanishita K; Viñuela F J Neurointerv Surg; 2013 Nov; 5 Suppl 3():iii38-42. PubMed ID: 23048176 [TBL] [Abstract][Full Text] [Related]
17. Thrombosis of a fusiform intracranial aneurysm induced by overlapping neuroform stents: case report. Ansari SA; Lassig JP; Nicol E; Thompson BG; Gemmete JJ; Gandhi D Neurosurgery; 2007 May; 60(5):E950-1; discussion E950-1. PubMed ID: 17460508 [TBL] [Abstract][Full Text] [Related]
18. The silk flow-diverting stent in the endovascular treatment of complex intracranial aneurysms: technical aspects and midterm results in 24 consecutive patients. Tähtinen OI; Manninen HI; Vanninen RL; Seppänen J; Niskakangas T; Rinne J; Keski-Nisula L Neurosurgery; 2012 Mar; 70(3):617-23; discussion 623-4. PubMed ID: 21866071 [TBL] [Abstract][Full Text] [Related]
19. Flow-independent dynamics in aneurysm (FIDA): pressure measurements following partial and complete flow impairment in experimental aneurysm model. Majidi S; Watanabe M; Chaudhry SA; Qureshi AI J Vasc Interv Neurol; 2014 Sep; 7(3):41-5. PubMed ID: 25298859 [TBL] [Abstract][Full Text] [Related]
20. Antiplatelet Management for Stent-Assisted Coiling and Flow Diversion of Ruptured Intracranial Aneurysms: A DELPHI Consensus Statement. Ospel JM; Brouwer P; Dorn F; Arthur A; Jensen ME; Nogueira R; Chapot R; Albuquerque F; Majoie C; Jayaraman M; Taylor A; Liu J; Fiehler J; Sakai N; Orlov K; Kallmes D; Fraser JF; Thibault L; Goyal M AJNR Am J Neuroradiol; 2020 Oct; 41(10):1856-1862. PubMed ID: 32943417 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]