353 related articles for article (PubMed ID: 21858864)
1. Understanding quantitative pulsed CEST in the presence of MT.
Desmond KL; Stanisz GJ
Magn Reson Med; 2012 Apr; 67(4):979-90. PubMed ID: 21858864
[TBL] [Abstract][Full Text] [Related]
2. A combined analytical solution for chemical exchange saturation transfer and semi-solid magnetization transfer.
Zaiss M; Zu Z; Xu J; Schuenke P; Gochberg DF; Gore JC; Ladd ME; Bachert P
NMR Biomed; 2015 Feb; 28(2):217-30. PubMed ID: 25504828
[TBL] [Abstract][Full Text] [Related]
3. Systematic Evaluation of Amide Proton Chemical Exchange Saturation Transfer at 3 T: Effects of Protein Concentration, pH, and Acquisition Parameters.
Schmidt H; Schwenzer NF; Gatidis S; Küstner T; Nikolaou K; Schick F; Martirosian P
Invest Radiol; 2016 Oct; 51(10):635-46. PubMed ID: 27272542
[TBL] [Abstract][Full Text] [Related]
4. Quantitative pulsed CEST-MRI using Ω-plots.
Meissner JE; Goerke S; Rerich E; Klika KD; Radbruch A; Ladd ME; Bachert P; Zaiss M
NMR Biomed; 2015 Oct; 28(10):1196-208. PubMed ID: 26278686
[TBL] [Abstract][Full Text] [Related]
5. Rapid and quantitative chemical exchange saturation transfer (CEST) imaging with magnetic resonance fingerprinting (MRF).
Cohen O; Huang S; McMahon MT; Rosen MS; Farrar CT
Magn Reson Med; 2018 Dec; 80(6):2449-2463. PubMed ID: 29756286
[TBL] [Abstract][Full Text] [Related]
6. Quantitative separation of CEST effect from magnetization transfer and spillover effects by Lorentzian-line-fit analysis of z-spectra.
Zaiss M; Schmitt B; Bachert P
J Magn Reson; 2011 Aug; 211(2):149-55. PubMed ID: 21641247
[TBL] [Abstract][Full Text] [Related]
7. Quantitative pulsed CEST-MRI at a clinical 3T MRI system.
Stabinska J; Cronenberg T; Wittsack HJ; Lanzman RS; Müller-Lutz A
MAGMA; 2017 Oct; 30(5):505-516. PubMed ID: 28569374
[TBL] [Abstract][Full Text] [Related]
8. Does the magnetization transfer effect bias chemical exchange saturation transfer effects? Quantifying chemical exchange saturation transfer in the presence of magnetization transfer.
Smith AK; Ray KJ; Larkin JR; Craig M; Smith SA; Chappell MA
Magn Reson Med; 2020 Sep; 84(3):1359-1375. PubMed ID: 32072677
[TBL] [Abstract][Full Text] [Related]
9. Investigation of optimizing and translating pH-sensitive pulsed-chemical exchange saturation transfer (CEST) imaging to a 3T clinical scanner.
Sun PZ; Benner T; Kumar A; Sorensen AG
Magn Reson Med; 2008 Oct; 60(4):834-41. PubMed ID: 18816867
[TBL] [Abstract][Full Text] [Related]
10. Optimization of pulse train presaturation for CEST imaging in clinical scanners.
Schmitt B; Zaiss M; Zhou J; Bachert P
Magn Reson Med; 2011 Jun; 65(6):1620-9. PubMed ID: 21337418
[TBL] [Abstract][Full Text] [Related]
11. Imaging pH using the chemical exchange saturation transfer (CEST) MRI: Correction of concomitant RF irradiation effects to quantify CEST MRI for chemical exchange rate and pH.
Sun PZ; Sorensen AG
Magn Reson Med; 2008 Aug; 60(2):390-7. PubMed ID: 18666128
[TBL] [Abstract][Full Text] [Related]
12. A review of optimization and quantification techniques for chemical exchange saturation transfer MRI toward sensitive in vivo imaging.
Kim J; Wu Y; Guo Y; Zheng H; Sun PZ
Contrast Media Mol Imaging; 2015; 10(3):163-178. PubMed ID: 25641791
[TBL] [Abstract][Full Text] [Related]
13. Optimizing pulsed-chemical exchange saturation transfer imaging sequences.
Zu Z; Li K; Janve VA; Does MD; Gochberg DF
Magn Reson Med; 2011 Oct; 66(4):1100-8. PubMed ID: 21432903
[TBL] [Abstract][Full Text] [Related]
14. Relaxation-compensated CEST-MRI at 7 T for mapping of creatine content and pH--preliminary application in human muscle tissue in vivo.
Rerich E; Zaiss M; Korzowski A; Ladd ME; Bachert P
NMR Biomed; 2015 Nov; 28(11):1402-12. PubMed ID: 26374674
[TBL] [Abstract][Full Text] [Related]
15. Inverse Z-spectrum analysis for spillover-, MT-, and T1 -corrected steady-state pulsed CEST-MRI--application to pH-weighted MRI of acute stroke.
Zaiss M; Xu J; Goerke S; Khan IS; Singer RJ; Gore JC; Gochberg DF; Bachert P
NMR Biomed; 2014 Mar; 27(3):240-52. PubMed ID: 24395553
[TBL] [Abstract][Full Text] [Related]
16. Simulation and optimization of pulsed radio frequency irradiation scheme for chemical exchange saturation transfer (CEST) MRI-demonstration of pH-weighted pulsed-amide proton CEST MRI in an animal model of acute cerebral ischemia.
Sun PZ; Wang E; Cheung JS; Zhang X; Benner T; Sorensen AG
Magn Reson Med; 2011 Oct; 66(4):1042-8. PubMed ID: 21437977
[TBL] [Abstract][Full Text] [Related]
17. Quantification of pulsed saturation transfer at 1.5T and 3T.
Chan RW; Myrehaug S; Stanisz GJ; Sahgal A; Lau AZ
Magn Reson Med; 2019 Nov; 82(5):1684-1699. PubMed ID: 31228291
[TBL] [Abstract][Full Text] [Related]
18. CEST imaging of fast exchanging amine pools with corrections for competing effects at 9.4 T.
Zhang XY; Wang F; Li H; Xu J; Gochberg DF; Gore JC; Zu Z
NMR Biomed; 2017 Jul; 30(7):. PubMed ID: 28272785
[TBL] [Abstract][Full Text] [Related]
19. Quantitative description of radiofrequency (RF) power-based ratiometric chemical exchange saturation transfer (CEST) pH imaging.
Wu R; Longo DL; Aime S; Sun PZ
NMR Biomed; 2015 May; 28(5):555-65. PubMed ID: 25807919
[TBL] [Abstract][Full Text] [Related]
20. Evaluating the use of a continuous approximation for model-based quantification of pulsed chemical exchange saturation transfer (CEST).
Tee YK; Khrapitchev AA; Sibson NR; Payne SJ; Chappell MA
J Magn Reson; 2012 Sep; 222(3):88-95. PubMed ID: 22858666
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]