668 related articles for article (PubMed ID: 21858999)
1. Modeling the truebeam linac using a CAD to Geant4 geometry implementation: dose and IAEA-compliant phase space calculations.
Constantin M; Perl J; LoSasso T; Salop A; Whittum D; Narula A; Svatos M; Keall PJ
Med Phys; 2011 Jul; 38(7):4018-24. PubMed ID: 21858999
[TBL] [Abstract][Full Text] [Related]
2. A geometrical model for the Monte Carlo simulation of the TrueBeam linac.
Rodriguez M; Sempau J; Fogliata A; Cozzi L; Sauerwein W; Brualla L
Phys Med Biol; 2015 Jun; 60(11):N219-29. PubMed ID: 25984796
[TBL] [Abstract][Full Text] [Related]
3. Monte Carlo simulation of TrueBeam flattening-filter-free beams using varian phase-space files: comparison with experimental data.
Belosi MF; Rodriguez M; Fogliata A; Cozzi L; Sempau J; Clivio A; Nicolini G; Vanetti E; Krauss H; Khamphan C; Fenoglietto P; Puxeu J; Fedele D; Mancosu P; Brualla L
Med Phys; 2014 May; 41(5):051707. PubMed ID: 24784373
[TBL] [Abstract][Full Text] [Related]
4. A Monte Carlo simulation framework for electron beam dose calculations using Varian phase space files for TrueBeam Linacs.
Rodrigues A; Sawkey D; Yin FF; Wu Q
Med Phys; 2015 May; 42(5):2389-403. PubMed ID: 25979034
[TBL] [Abstract][Full Text] [Related]
5. A Monte Carlo approach to validation of FFF VMAT treatment plans for the TrueBeam linac.
Gete E; Duzenli C; Milette MP; Mestrovic A; Hyde D; Bergman AM; Teke T
Med Phys; 2013 Feb; 40(2):021707. PubMed ID: 23387730
[TBL] [Abstract][Full Text] [Related]
6. Determination of the initial beam parameters in Monte Carlo linac simulation.
Aljarrah K; Sharp GC; Neicu T; Jiang SB
Med Phys; 2006 Apr; 33(4):850-8. PubMed ID: 16696460
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of latent variances in Monte Carlo dose calculations with Varian TrueBeam photon phase-spaces used as a particle source.
Alhakeem E; Zavgorodni S
Phys Med Biol; 2017 Dec; 63(1):01NT03. PubMed ID: 29205177
[TBL] [Abstract][Full Text] [Related]
8. Monte carlo electron source model validation for an Elekta Precise linac.
Ali OA; Willemse CA; Shaw W; O'Reilly FH; du Plessis FC
Med Phys; 2011 May; 38(5):2366-73. PubMed ID: 21776771
[TBL] [Abstract][Full Text] [Related]
9. Part II: Verification of the TrueBeam head shielding model in Varian VirtuaLinac via out-of-field doses.
Wijesooriya K; Liyanage NK; Kaluarachchi M; Sawkey D
Med Phys; 2019 Feb; 46(2):877-884. PubMed ID: 30368838
[TBL] [Abstract][Full Text] [Related]
10. Validation of a virtual source model of medical linac for Monte Carlo dose calculation using multi-threaded Geant4.
Aboulbanine Z; El Khayati N
Phys Med Biol; 2018 Apr; 63(8):085008. PubMed ID: 29553478
[TBL] [Abstract][Full Text] [Related]
11. Monte Carlo modeling of HD120 multileaf collimator on Varian TrueBeam linear accelerator for verification of 6X and 6X FFF VMAT SABR treatment plans.
Bergman AM; Gete E; Duzenli C; Teke T
J Appl Clin Med Phys; 2014 May; 15(3):4686. PubMed ID: 24892341
[TBL] [Abstract][Full Text] [Related]
12. Photon beam relative dose validation of the DPM Monte Carlo code in lung-equivalent media.
Chetty IJ; Charland PM; Tyagi N; McShan DL; Fraass BA; Bielajew AF
Med Phys; 2003 Apr; 30(4):563-73. PubMed ID: 12722808
[TBL] [Abstract][Full Text] [Related]
13. Monte Carlo validation of the TrueBeam 10XFFF phase-space files for applications in lung SABR.
Teke T; Duzenli C; Bergman A; Viel F; Atwal P; Gete E
Med Phys; 2015 Dec; 42(12):6863-74. PubMed ID: 26632043
[TBL] [Abstract][Full Text] [Related]
14. Monte Carlo modeling and simulations of the High Definition (HD120) micro MLC and validation against measurements for a 6 MV beam.
Borges C; Zarza-Moreno M; Heath E; Teixeira N; Vaz P
Med Phys; 2012 Jan; 39(1):415-23. PubMed ID: 22225311
[TBL] [Abstract][Full Text] [Related]
15. Monte Carlo modeling of Halcyon and Ethos radiotherapy beam using CAD geometry: validation and IAEA-compliant phase space.
Laakkonen L; Lehtomäki J; Cahill A; Constantin M; Kulmala A; Harju A
Phys Med Biol; 2023 Feb; 68(4):. PubMed ID: 36657172
[No Abstract] [Full Text] [Related]
16. Final Aperture Superposition Technique applied to fast calculation of electron output factors and depth dose curves.
Faddegon BA; Villarreal-Barajas JE
Med Phys; 2005 Nov; 32(11):3286-94. PubMed ID: 16370417
[TBL] [Abstract][Full Text] [Related]
17. Monte Carlo simulation of beam characteristics from small fields based on TrueBeam flattening-filter-free mode.
Feng Z; Yue H; Zhang Y; Wu H; Cheng J; Su X
Radiat Oncol; 2016 Feb; 11():30. PubMed ID: 26921246
[TBL] [Abstract][Full Text] [Related]
18. Validation of a Monte Carlo model for multi leaf collimator based electron delivery.
Kaluarachchi MM; Saleh ZH; Schwer ML; Klein EE
Med Phys; 2020 Aug; 47(8):3586-3599. PubMed ID: 32324289
[TBL] [Abstract][Full Text] [Related]
19. SU-E-T-499: Validation of the Varian Generic Phase Space Files for Monte Carlo Calculations of Dose Distributions for the TrueBeam Linac Head.
Wang L; Xing L; Sawkey D; Constantin M; Svatos M; Mok E
Med Phys; 2012 Jun; 39(6Part17):3820. PubMed ID: 28517461
[TBL] [Abstract][Full Text] [Related]
20. On the discrepancies between Monte Carlo dose calculations and measurements for the 18 MV varian photon beam.
Chibani O; Ma CM
Med Phys; 2007 Apr; 34(4):1206-16. PubMed ID: 17500452
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]