467 related articles for article (PubMed ID: 21860076)
1. Low-dose CT reconstruction via edge-preserving total variation regularization.
Tian Z; Jia X; Yuan K; Pan T; Jiang SB
Phys Med Biol; 2011 Sep; 56(18):5949-67. PubMed ID: 21860076
[TBL] [Abstract][Full Text] [Related]
2. Low dose CBCT reconstruction via prior contour based total variation (PCTV) regularization: a feasibility study.
Chen Y; Yin FF; Zhang Y; Zhang Y; Ren L
Phys Med Biol; 2018 Apr; 63(8):085014. PubMed ID: 29537385
[TBL] [Abstract][Full Text] [Related]
3. Combined iterative reconstruction and image-domain decomposition for dual energy CT using total-variation regularization.
Dong X; Niu T; Zhu L
Med Phys; 2014 May; 41(5):051909. PubMed ID: 24784388
[TBL] [Abstract][Full Text] [Related]
4. Low-dose 4DCT reconstruction via temporal nonlocal means.
Tian Z; Jia X; Dong B; Lou Y; Jiang SB
Med Phys; 2011 Mar; 38(3):1359-65. PubMed ID: 21520846
[TBL] [Abstract][Full Text] [Related]
5. Adaptive-weighted high order TV algorithm for sparse-view CT reconstruction.
Xi Y; Zhou P; Yu H; Zhang T; Zhang L; Qiao Z; Liu F
Med Phys; 2023 Sep; 50(9):5568-5584. PubMed ID: 36934310
[TBL] [Abstract][Full Text] [Related]
6. Sparse-view computed tomography image reconstruction via a combination of L(1) and SL(0) regularization.
Qi H; Chen Z; Guo J; Zhou L
Biomed Mater Eng; 2015; 26 Suppl 1():S1389-98. PubMed ID: 26405900
[TBL] [Abstract][Full Text] [Related]
7. Median prior constrained TV algorithm for sparse view low-dose CT reconstruction.
Liu Y; Shangguan H; Zhang Q; Zhu H; Shu H; Gui Z
Comput Biol Med; 2015 May; 60():117-31. PubMed ID: 25817533
[TBL] [Abstract][Full Text] [Related]
8. Low-dose CT statistical iterative reconstruction via modified MRF regularization.
Shangguan H; Zhang Q; Liu Y; Cui X; Bai Y; Gui Z
Comput Methods Programs Biomed; 2016 Jan; 123():129-41. PubMed ID: 26542474
[TBL] [Abstract][Full Text] [Related]
9. Accelerated barrier optimization compressed sensing (ABOCS) reconstruction for cone-beam CT: phantom studies.
Niu T; Zhu L
Med Phys; 2012 Jul; 39(7):4588-98. PubMed ID: 22830790
[TBL] [Abstract][Full Text] [Related]
10. Gamma regularization based reconstruction for low dose CT.
Zhang J; Chen Y; Hu Y; Luo L; Shu H; Li B; Liu J; Coatrieux JL
Phys Med Biol; 2015 Sep; 60(17):6901-21. PubMed ID: 26305538
[TBL] [Abstract][Full Text] [Related]
11. Low dose CT reconstruction via L1 norm dictionary learning using alternating minimization algorithm and balancing principle.
Wu J; Dai F; Hu G; Mou X
J Xray Sci Technol; 2018; 26(4):603-622. PubMed ID: 29689766
[TBL] [Abstract][Full Text] [Related]
12. Smoothed
Li M; Zhang C; Peng C; Guan Y; Xu P; Sun M; Zheng J
Biomed Res Int; 2016; 2016():2180457. PubMed ID: 27725935
[TBL] [Abstract][Full Text] [Related]
13. Simultaneous deblurring and iterative reconstruction of CBCT for image guided brain radiosurgery.
Hashemi S; Song WY; Sahgal A; Lee Y; Huynh C; Grouza V; Nordström H; Eriksson M; Dorenlot A; Régis JM; Mainprize JG; Ruschin M
Phys Med Biol; 2017 Apr; 62(7):2521-2541. PubMed ID: 28248652
[TBL] [Abstract][Full Text] [Related]
14. Fast compressed sensing-based CBCT reconstruction using Barzilai-Borwein formulation for application to on-line IGRT.
Park JC; Song B; Kim JS; Park SH; Kim HK; Liu Z; Suh TS; Song WY
Med Phys; 2012 Mar; 39(3):1207-17. PubMed ID: 22380351
[TBL] [Abstract][Full Text] [Related]
15. Iterative image-domain decomposition for dual-energy CT.
Niu T; Dong X; Petrongolo M; Zhu L
Med Phys; 2014 Apr; 41(4):041901. PubMed ID: 24694132
[TBL] [Abstract][Full Text] [Related]
16. Iterative image reconstruction algorithm analysis for optical CT radiochromic gel dosimetry.
Collins S; Ogilvy A; Hare W; Hilts M; Jirasek A
Biomed Phys Eng Express; 2024 Apr; 10(3):. PubMed ID: 38579691
[No Abstract] [Full Text] [Related]
17. Noise-resolution tradeoffs in x-ray CT imaging: a comparison of penalized alternating minimization and filtered backprojection algorithms.
Evans JD; Politte DG; Whiting BR; O'Sullivan JA; Williamson JF
Med Phys; 2011 Mar; 38(3):1444-58. PubMed ID: 21520856
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of the OSC-TV iterative reconstruction algorithm for cone-beam optical CT.
Matenine D; Mascolo-Fortin J; Goussard Y; Després P
Med Phys; 2015 Nov; 42(11):6376-86. PubMed ID: 26520729
[TBL] [Abstract][Full Text] [Related]
19. Technical Note: Iterative megavoltage CT (MVCT) reconstruction using block-matching 3D-transform (BM3D) regularization.
Lyu Q; Yang C; Gao H; Xue Y; O'Connor D; Niu T; Sheng K
Med Phys; 2018 Jun; 45(6):2603-2610. PubMed ID: 29663467
[TBL] [Abstract][Full Text] [Related]
20. Noise spatial nonuniformity and the impact of statistical image reconstruction in CT myocardial perfusion imaging.
Lauzier PT; Tang J; Speidel MA; Chen GH
Med Phys; 2012 Jul; 39(7):4079-92. PubMed ID: 22830741
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]