BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

212 related articles for article (PubMed ID: 21863305)

  • 21. Olecranon fractures repaired with FiberWire or metal wire tension banding: a biomechanical comparison.
    Carofino BC; Santangelo SA; Kabadi M; Mazzocca AD; Browner BD
    Arthroscopy; 2007 Sep; 23(9):964-70. PubMed ID: 17868835
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [EFFECTIVENESS OF ARTHROSCOPIC ULTRA-Braid SUTURE PLANE FIXATION FOR ANTERIOR CRUCIATE LIGAMENT TIBIAL EMINENCE AVULSION FRACTURES].
    Wang J; Weng X; Li J; Chen X
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2015 Nov; 29(11):1353-7. PubMed ID: 26875266
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Effectiveness of arthroscopic treatment of anterior cruciate ligament tibial eminence avulsion fracture with non-absorbable suture fixation combined with mini-plate].
    Wang S; Xiao Y; Tong Z; Li G; Jiang J; Yao J; Wu Z; Li T; Wu Q
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2013 Sep; 27(9):1041-4. PubMed ID: 24279010
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Biomechanical evaluation of tibial eminence fractures using suture fixation.
    Aoki SK; Curtis SH
    Orthopedics; 2011 Dec; 34(12):e866-70. PubMed ID: 22146203
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Arthroscopic treatment of anterior cruciate ligament tibial eminence avulsion fracture with double heads compressive cannulated screw fixation in adolescents].
    Liu J; Yue Y; Li Z
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2018 Sep; 32(9):1172-1176. PubMed ID: 30129349
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Combining pullout suture and retrograde screw fixation for anterior cruciate ligament tibial eminence avulsion fractures: A case report.
    Hiranaka T; Furumatsu T; Tanaka T; Okazaki Y; Kodama Y; Kamatsuki Y; Masuda K; Seno N; Ozaki T
    J Orthop Surg (Hong Kong); 2020; 28(2):2309499020918681. PubMed ID: 32489139
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Displaced olecranon fractures in children: a biomechanical analysis of fixation methods.
    Parent S; Wedemeyer M; Mahar AT; Anderson M; Faro F; Steinman S; Lalonde F; Newton P
    J Pediatr Orthop; 2008 Mar; 28(2):147-51. PubMed ID: 18388706
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Biomechanical evaluation of the tension band wiring principle. A comparison between two different techniques for transverse patella fracture fixation.
    Zderic I; Stoffel K; Sommer C; Höntzsch D; Gueorguiev B
    Injury; 2017 Aug; 48(8):1749-1757. PubMed ID: 28622833
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Biomechanical evaluation of different fixation methods for tibial eminence fractures.
    Eggers AK; Becker C; Weimann A; Herbort M; Zantop T; Raschke MJ; Petersen W
    Am J Sports Med; 2007 Mar; 35(3):404-10. PubMed ID: 17170161
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Interference screw fixation of doubled flexor tendon graft in anterior cruciate ligament reconstruction - biomechanical evaluation with cyclic elongation.
    Nakano H; Yasuda K; Tohyama H; Yamanaka M; Wada T; Kaneda K
    Clin Biomech (Bristol, Avon); 2000 Mar; 15(3):188-95. PubMed ID: 10656980
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Effectiveness comparison of two arthroscopic different fixations for anterior cruciate ligament tibial eminence avulsion fractures].
    Li H; Wu H; Wu Y; Fu P; Zhu Y
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2011 Aug; 25(8):899-902. PubMed ID: 21923012
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Biomechanical stability of different suture fixation techniques for tibial eminence fractures.
    Schneppendahl J; Thelen S; Gehrmann S; Twehues S; Eichler C; Koebke J; Windolf J; Hakimi M; Wild M
    Knee Surg Sports Traumatol Arthrosc; 2012 Oct; 20(10):2092-7. PubMed ID: 22203047
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Biomechanical comparison of tension band- and interfragmentary screw fixation with a new implant in transverse patella fractures.
    Dargel J; Gick S; Mader K; Koebke J; Pennig D
    Injury; 2010 Feb; 41(2):156-60. PubMed ID: 19665707
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Simple and safe arthroscopic placement and removal of cannulated screw and washer for fixation of tibial avulsion fracture of the anterior cruciate ligament.
    Veselko M; Senekovic V; Tonin M
    Arthroscopy; 1996 Apr; 12(2):259-62. PubMed ID: 8777010
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction. Part II: tibial site.
    Kousa P; Järvinen TL; Vihavainen M; Kannus P; Järvinen M
    Am J Sports Med; 2003; 31(2):182-8. PubMed ID: 12642250
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The effect of cyclic loading on the biomechanical characteristics of the femur-graft-tibia complex after anterior cruciate ligament reconstruction using Bone Mulch screw/WasherLoc fixation.
    Kudo T; Tohyama H; Minami A; Yasuda K
    Clin Biomech (Bristol, Avon); 2005 May; 20(4):414-20. PubMed ID: 15737449
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Biomechanical Evaluation of Transverse Patella Fracture Fixation Using Headless Screws: A Comparison of Suture Versus Cable as a Tension Band.
    Bric JD; Martin JM; McGrady LM; Wang M; Schmeling GJ
    J Orthop Trauma; 2023 Jun; 37(6):e253-e257. PubMed ID: 36729011
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparison of screw post fixation and free bone block interference fixation for anterior cruciate ligament soft tissue grafts: biomechanical considerations.
    Novak PJ; Wexler GM; Williams JS; Bach BR; Bush-Joseph CA
    Arthroscopy; 1996 Aug; 12(4):470-3. PubMed ID: 8864006
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Biomechanics test of fixation of star-shaped six-part patellar fractures with petal-shaped poly-axial locking plate].
    Meng D; Ouyang Y; Chen H; Zhou J; Xie Z; Lin Y; Lin H; Hou C
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2018 Mar; 32(3):311-315. PubMed ID: 29806280
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Titanium mesh as a low-profile alternative for tension-band augmentation in patella fracture fixation: A biomechanical study.
    Dickens AJ; Salas C; Rise L; Murray-Krezan C; Taha MR; DeCoster TA; Gehlert RJ
    Injury; 2015; 46(6):1001-6. PubMed ID: 25769202
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.